- All
- Favorite
- Popular
- Most rated
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 262 Series |
| Mounting Compatibility | TO-Can, Butterfly, C-Mount, and Custom Packages |
| Thermal Control | Integrated Peltier-based Temperature Controller (±0.1 °C Stability) |
| Electrical Interface | DB-15 / DB-9 / 9W4 Connector |
| Cooling | Forced-air with High-Conductivity Heat Sink |
| Compliance | RoHS-compliant, CE-marked, Designed for GLP-Compatible Lab Environments |
| Software Integration | Compatible with Arroyo’s TECSource™ Control Suite (USB/RS-232) |
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 6301 |
| Laser Current Range | 100 mA to 4 A (selectable per variant) |
| Output Voltage | Up to 10 V |
| Current Accuracy | 0.025% + 0.03 mA |
| Current Noise | < 1 µA RMS |
| Control Bandwidth | 325 kHz |
| TEC Power | 60 W |
| Temperature Sensor Support | Thermistor, RTD, LM335, AD590 |
| Interfaces | USB, RS-232 |
| Isolation | Optically and electrically isolated I/O |
| Compliance | CE, RoHS, FCC Class A |
| Software Compatibility | LabVIEW, Python, MATLAB via ASCII command protocol |
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 485 Series |
| Output Current Range | up to 10 A |
| Output Voltage Range | up to 15 V |
| Current Accuracy | 0.05% + offset (e.g., 0.4–1.6 mA) |
| Current Noise | < 60 µA RMS |
| Bandwidth | 45–65 kHz |
| Temperature Stability | ±0.004°C |
| Compatible Sensors | Thermistor, RTD |
| Control Interfaces | USB, RS-232, Analog (0–5 V or 0–10 V) |
| Power Output (TECPak) | 32 W / 55 W |
| Form Factor | Compact OEM module (≈1/3 volume of benchtop equivalents) |
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 7000 Series |
| Form Factor | 1U or 2U Rack-Mountable / Benchtop |
| Laser Driver Channels | Up to 4 per unit |
| Max Laser Current | 4 A |
| Max Laser Voltage | 8 V |
| TEC Driver Channels | Up to 4 per unit |
| Max TEC Current | 18 A |
| Max TEC Voltage | 28 V |
| Max TEC Power | 420 W |
| Temperature Stability (24 h) | ±0.1 °C |
| Short-Term Stability (1 h) | <0.004 °C |
| Control Interface | Ethernet, USB |
| PID Auto-Tuning | Yes |
| Compatibility | ILX Lightwave & Newport TEC/LD command set |
| Input Power | Universal AC (90–264 VAC, 47–63 Hz) |
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 5240 |
| Temperature Stability | ±0.004 °C |
| Control Power Range | 28 W |
| Max Current | 4 A |
| Max Voltage | 7 V |
| Supported Sensors | Thermistor |
| Interface | USB, RS-232 |
| AutoTune PID Function | Yes |
| Display | High-contrast VFD |
| Brand | Arroyo Instruments |
|---|---|
| Origin | USA |
| Model | 4201 |
| Current Range | 100 mA to 20 A (dual-range configuration) |
| Output Voltage | Up to 10 V |
| Accuracy | 0.025% + 0.03 mA |
| Current Noise | < 1 µA RMS |
| Small-Signal Bandwidth | 325 kHz |
| Interface | USB & RS-232 |
| Isolation | Fully galvanically isolated I/O (input/output, photodiode input, laser output) |
| Modulation | Analog voltage input (0–5 V or ±5 V), hardware-protected |
| QCW Option | Not available on 4201 (standard CW only) |
| Compliance | CE, RoHS, FCC Class B |
| Software Compatibility | SCPI-compliant command set, backward-compatible with industry-standard laser controller protocols |
| Brand | Thorlabs |
|---|---|
| Model | MAX601D |
| Type | Manual 6-Axis Nanopositioning Flexure Stage |
| Travel (X/Y/Z) | 4 mm |
| Travel (θx/θy/θz) | 6° (105 mrad) |
| Fine Adjustment Range (X/Y/Z) | 300 µm |
| Fine Adjustment Range (θx/θy/θz) | 18 arcmin (5.2 mrad) |
| Coarse Adjustment Resolution | 5 µm |
| Fine Adjustment Resolution | 0.5 µm |
| Maximum Load Capacity | 1 kg |
| Platform Height | 112.5 mm |
| Stiffness (X/Z) | 1 N/µm |
| Stiffness (Y) | 0.5 N/µm |
| Resonant Frequency | >130 Hz (±10%) |
| Common Rotation Pivot | Yes |
| Coupled Actuator Mounting | Yes |
| Compatibility | DRV3 Differential Micrometers (pre-installed) |
| Modular Drive Interface | Yes |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Model | 9030 Series |
| Spectral Range | 250–700 nm |
| Stray Light | 1.00E−03 |
| Grating Configuration | Dual Grating (Subtractive Mode) |
| Focal Length | 100 mm (Input & Output) |
| Optical Layout | Seya-Namioka |
| Grating Type | Concave Holographic |
| f-number | f/3.2 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.25 nm |
| Slit Options | Removable fixed-width slits (100 µm to 3 mm) |
| Detector Interface | Single-channel PMT-compatible output |
| Software Control | USB 2.0 (motorized version only) |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows requiring traceable wavelength calibration and audit-ready operation |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SF Series |
| Price Range | USD 13,500 – 13,700 (FOB) |
| Operating Mode | Steady-State |
| Classification | Class AAA (per IEC 60904-9:2020 & ASTM E927-22) |
| Collimation | ≥95% collimated output (full-angle divergence < 2°) |
| Spectral Match | AM0 (space) and AM1.5G (terrestrial) configurable via interchangeable filter sets |
| Spatial Uniformity | ≤2% (measured over 2×2 cm² test area) |
| Temporal Stability | ≤0.5% RMS over 30 min (Class A per standard) |
| Brand | TMC |
|---|---|
| Origin | USA |
| Model | STACIS III |
| Active DOF | 6 |
| Active Bandwidth | 0.6–150 Hz |
| Passive Natural Frequency | 18 Hz (vertical & horizontal) |
| Effective Active Resonant Frequency | 0.5 Hz |
| Isolation at 1 Hz | 40–70% |
| Isolation ≥2 Hz | ≥90% |
| Settling Time (10 lb step, 10 | 1): 0.3 sec |
| Internal Noise | <0.1 nm RMS |
| Load Range per Isolator | Low (181–499 kg), Med (408–953 kg), Hi (862–2041 kg) |
| Static Lift Capacity | 4090 kg |
| Stiffness (Med isolator, 454 kg) | 73 × 10⁵ N/m |
| Magnetic Emission (<102 mm) | <0.02 µG broadband RMS |
| Environmental Compliance | CE, RoHS |
| Operating Temp | 10–32 °C |
| Humidity | 30–60% RH |
| Power | 100–240 VAC, 50/60 Hz, <600 W |
| Isolator Dimensions | 300 × 320 × 275 mm |
| Isolator Weight | 34 kg |
| DC-2020 Controller | Dual-core 150/75 MHz, 10 kHz sampling, 16 AI/AO channels, Ethernet + USB + RS-232, embedded GUI |