Refrigeration Equipment
Filter
Showing 691–720 of 1586 results
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Variants | Triton LN10 F / LN10 / LN20 |
| Pricing | Available Upon Request |
| Brand | Physik |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Ucryo-300 |
| Pricing | Available Upon Request |
| Brand | Physik |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Vcryo-V-200 |
| Temperature Setpoint Range | 78.5 K – 500 K |
| Working Distance | 2 mm |
| Vibration Stability | ±5 nm |
| Unit Weight | 1.5 kg |
| Cooling Medium | Liquid Nitrogen |
| Initial Cool-down Time | <10 min |
| LN₂ Consumption Rate | 0.2 L/h |
| Compact Dimensions | 3 cm (thickness) × 29 cm (length) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Cryogenic Equipment |
| Model | Acryo-1.5K |
| Pricing | Available Upon Request |
| Brand | Physiké |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Acryo-4K |
| Pricing | Available Upon Request |
| Brand | Physiké |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Acryo-TL-1.5K |
| Pricing | Upon Request |
| Brand | Physiké |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Acryo-TL-4K |
| Cooling Method | Gifford-McMahon or Pulse Tube Refrigeration |
| Base Temperature | ≤4.2 K (standard), optional 1.5 K single-shot mode |
| Sample Loading | Top-loading via removable sample probe |
| Sample Tube ID | Standard 55 mm (customizable) |
| Vibration Mitigation | Cryocooler head suspension + sand-damped base |
| Optical Access | Optional visible/IR/THz/X-ray/neutron windows |
| Magnetic Compatibility | Compact tail configuration for superconducting/electromagnets |
| Software Interface | RS-232/RS-485/Ethernet for remote control and logging |
| Compliance | Designed to meet GLP/GMP-relevant operational traceability requirements |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CryoAce-100 |
| Cooling Medium | Helium Gas |
| Base Plate Diameters | 5 cm, 10 cm, 15 cm, 20 cm |
| Nominal Vibration Amplitude | 6–12 nm (RMS, dependent on base plate size and operating temperature) |
| Base Temperature Range | 2.4 K – 3.2 K |
| Standard Configuration | Top and/or Side Optical Windows, Vacuum Gauge, Calibrated Platinum Resistance Thermometer (PRT) |
| Integrated Cryo-Pumping | Multi-stage低温 adsorption pumps |
| Compressor Type | Air-Cooled Helium Compressor |
| Power Supply | Single-Phase AC, Low Power Consumption |
| Footprint | Compact Desktop Form Factor |
| Vacuum Maintenance | Self-Sustaining High Vacuum Without Continuous External Pumping |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CryoAce-200 |
| Vibration Stability | 12 nm (RMS) |
| Cooling Medium | Helium Gas |
| Baseplate Diameters Available | 5 cm, 10 cm, 15 cm, 20 cm |
| Base Temperature Range | 2.4 K – 3.2 K (dependent on configuration) |
| Standard Viewports | Top and/or Side |
| Power Supply | Single-Phase, Low Power Consumption |
| Footprint | Compact Desktop Form Factor |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-100 |
| Ultimate Temperature | < 350 mK |
| Cooling Source | 4 K Pulse Tube or Gifford-McMahon Refrigerator |
| Integrated 4 K Cold Head | Yes |
| Gas Recirculation System | External High-Speed Vacuum Pump Array + Purification & Condensation Loop |
| Liquid Nitrogen Cold Trap | Included |
| Thermal Switch | High-Performance Active Type |
| Optional Configurations | Top-Loading with Load-Lock Insert, Integrated Superconducting Magnet |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-200 |
| Base Temperature | < 350 mK |
| Cooling Architecture | Split-system (external Qcryo® helium-recycling cryocooler) |
| Vibration Isolation | Active mechanical decoupling between compressor/coldhead and He-3 insert |
| Vacuum Compatibility | UHV-compatible (bakeable to 150 °C) |
| Optional Integration | Superconducting magnet (up to 9 T, persistent mode) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Cryocloud-300 |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Cryocloud-400 |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-500 |
| Pricing | Upon Request |
| Compatible Cryostat Platforms | Acryo-1.5K (top-loading 1.5 K cryostat), CryoM (dry, variable-temperature superconducting magnet system) |
| Base Temperature (no-load) | < 270 mK |
| Hold Time | > 60 hours |
| Cooling Power at 350 mK | > 100 µW |
| Internal Cryopumping | Integrated low-temperature adsorption pump |
| Helium-3 Circuit | Sealed, single-shot operation |
| Sample Environment | High-vacuum standard |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Labcryo |
| Temperature Range | -50 °C to +200 °C |
| Temperature Stability | Better than ±25 mK |
| Cooling Method | Multi-stage Peltier (Thermoelectric) |
| Vacuum Feedthrough Options | Multi-pin, SMA / 2.92 mm / 1.85 mm Microwave, BNC, Triax, Fiber Optic |
| Sample Holders | Electrical pucks (DIP, LCC), Transmission holders, Solar cell mounts, Probe-based holders |
| Optical Windows | Gamma-ray, X-ray, UV, Vis, IR, THz-transparent options |
| Low-Temp Cabling | Twisted-pair, Flexible coaxial, Semi-rigid microwave, Triaxial cables |
| Mounting | Omnidirectional (no orientation dependency) |
| Power Supply | Standard AC input (no cryogens required) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Qcryo |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Scryo-S-100 |
| Minimum Temperature | 2 K |
| Cryogen Medium | Helium Gas (Gaseous or Liquid Helium Compatible) |
| Temperature Range | 2 K to 420 K (standard), up to 800 K with high-temperature option |
| Cooling Method | Continuous-flow cryogenic system with integrated high-efficiency vaporizer and ultra-low-loss flexible transfer line |
| Standard Sensor | Calibrated ZrON resistance thermometer |
| Control Precision | High-stability closed-loop temperature control via external precision temperature controller |
| Brand | Physike |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Scryo-S-200 |
| Pricing | Available Upon Request |
| Vacuum Compatibility | UHV (≤1×10⁻¹⁰ mbar) |
| Bakeable Temperature | ≥150 °C |
| Cold Plate Diameter | 15 cm (standard), up to 25 cm (custom) |
| Base Temperature | <2.4 K (with Qcryo® helium recirculator) |
| Temperature Stability | ±2.5 mK over 10 min |
| Vibration Amplitude (FFT, 2.5 kHz) | X < 2 nm, Y < 2.5 nm, Z < 3 nm |
| Cooling Power | >650 mW at 4.2 K |
| Customization Options | Multi-layer radiation shields, side/roof viewports (up to 8 side + 3 top), UHV-compatible electrical feedthroughs (DC: up to 200 leads |
| RF | 4 coaxial lines), custom vacuum chamber integration |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Scryo-S-300 |
| Vibration Stability | ±5 nm |
| Circulating Medium | Helium Gas |
| Cooling Architecture | Continuous-Flow Open-Cycle |
| Optional Dry-Cycle Integration | Compatible with Qcryo® Helium Recirculation System |
| Brand | Physiké |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Scryo-S-400 |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Scryo-S-500 |
| Temperature Stability | < ±25 mK |
| Base Temperature | < 2.2 K |
| Vibration Level | < 5 nm (peak-to-peak) |
| Cooling Medium | Helium gas (closed-cycle option with Qcryo® system) |
| Operating Range | < 1.8 K – 420 K (pumped below 4.5 K) |
| Drift Rate | < 2 nm/min |
| Helium Consumption | < 0.55 L/hr @ 5 K (open-cycle) |
| Optical Windows | Standard fused silica |
| Vacuum Feedthroughs | SMA/2.92 mm/2.4 mm/1.85 mm microwave, BNC, Triax, fiber optic, multi-pin |
| Sample Holders | Puck, DIP, LCC, transmission, solar cell, thermal transport configurations |
| Optional Integration | Nanopositioning stages, DACs, superconducting magnets, vertical extension, stainless-steel vacuum chamber with indium-sealed flanges |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Scryo-SDV |
| Pricing | Available Upon Request |
| Cooling Medium | Dual Liquid Helium & Liquid Nitrogen Reservoirs |
| Temperature Range | 1.5 K to 300 K |
| Static Liquid Helium Consumption Rate | < 0.1 L/h |
| Tail Length | > 1 m |
| Tail Outer Diameter | 47.8 mm |
| Sample Tube Inner Diameter | 31.5 mm |
| Design | Top-Loading, Plug-in Sample Rod Configuration |
| Thermal Architecture | Ultra-Low Heat Leak with LN₂ Radiation Shield & Superinsulated Sample Tube |
| Optional Configurations | Linear Actuator Sample Rod, Single/Double-Axis Rotating Sample Rod, Puck Holder, In-situ Pressure-Tuning Sample Rod, AC Susceptibility Measurement Kit, Static Helium Gas Environment |
| Vacuum Feedthrough Options | Multi-pin, BNC, SMA, Fiber Optic, Twisted Pair, Coaxial/Triaxial, Semi-Rigid RF Cable, Optical Fiber |
| Optical Window Compatibility | Gamma, X-ray, UV–Vis–IR–THz Transmission |
| Magnet Integration | Compatible with Electromagnets, Superconducting Magnets, Hybrid High-Field Magnets (e.g., 35 T Water-Cooled) |
| Application-Specific Adaptations | NMR Magnet Coupling, DAC (Diamond Anvil Cell), Hydrostatic Pressure Cells, AFM/STM Vibration-Sensitive Mounting |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Scryo-SV |
| Pricing | Upon Request |
| Brand | Physike |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Ucryo-100 |
| Pricing | Available Upon Request |
| Brand | Physike |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Ucryo-200 |
| Pricing | Available Upon Request |
| Brand | Physike |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Vcryo-V-100 |
| Price | Upon Request |
| Temperature Stability | ±25 mK |
| Operating Temperature Range | 65 K to 500 K (optional upgrade to 800 K) |
| Dewar Volume | 0.4 L |
| Cooling Medium | Liquid Nitrogen |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MAXCOOL 2500 L |
| Maximum Load | 2500 W |
| Operating Temperature Range | –120 °C to –145 °C |
| Water Vapor Pumping Speed (actual) | 140,000 L/s |
| Ultimate Vacuum | 1 × 10⁻⁹ mbar |
| Starting Pressure | ≤1 atm |
| Defrost Time | 4.0 min |
| Cold Surface Area | 1.4 m² |
| Cooling Water Flow Rate (at 13 °C ΔT) | 13.6 L/min |
| Noise Level (max) | 68 dB(A) |
| Footprint (min) | 0.403 m³ |
| Weight | 544 kg |
| Compliance | CE, UL Listed, RoHS Compliant |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MaxCool 4000 H |
| Cooling Method | Water-Cooled |
| Circulating Pump Pressure | 7 × 10⁻⁸ mbar |
| Refrigeration Capacity | 4000 W |
| Condensing Surface Area | 2.2 m² |
| Cold Trap Tube Diameter | 16 mm |
| Single-Loop Tube Length | 43 m |
| Dual-Loop Tube Length | 2 × 21.9 m |
| Standard Cold Finger Length | 2.44 m |
| Cooling Water Flow Rate (at ΔT = 13°C/26°C/29°C) | 13.6 / 27.3 / 54.1 L/min |
| Noise Level | ≤78 dB(A) |
| Dimensions (Min. Footprint) | 34 m³ |
| Weight | 533 kg |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MaxCool Series |
| Cooling Principle | Meissner Absorption Cycle |
| Refrigerant | Proprietary Non-Toxic, Recyclable Cryogenic Fluid |
| Ultimate Vacuum | 4×10⁻⁸ to 1×10⁻⁹ mbar |
| Maximum Condensing Load | 4000 W |
| Water Vapor Pumping Speed | Up to 220,000 L/s |
| Mounting | Direct Integration into Vacuum Chamber via Custom Cryocoil |
| Compliance | Designed for ISO/IEC 17025-aligned vacuum system integration |
| Brand | PRI-ECO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Integrated System |
| Circulating Pump Flow Rate | 11 L/min (customizable) |
| Operating Mode | Multi-Channel Dual-Switching with Quadruple Cold Traps in Alternating Dual-Mode |
| Primary Dehydration Temperature Range | 0–2 °C |
| Secondary Dehydration Temperature | −78 °C |
| Residual Moisture Output | < 0.01 % @ 500 mL/min |
| Dry Gas Output | ≤ 0.9 L/min (adjustable) |
| Sample Inlet Temperature Range | −50 to 60 °C |
| Total Gas Pathways | 9 + 8 (4 reference gas, 2 target gas, 3 QC gas, 8 sample gas) |
| Main Pump Flow | 11 L/min |
| Input Humidity Tolerance | < 99 % RH (non-condensing) |
| Communication Interfaces | RS232, RS485, USB |
| Power Supply | 230 V AC |
| Power Consumption | < 750 W (steady-state), < 1350 W (defrost cycle), < 1500 W (peak, dual-trap active) |
| Dimensions | 440 mm × 820 mm × 820 mm |
| Weight | 120 kg |