Showing 121–150 of 248 results
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 50°C |
| Humidity Range | 85–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| SO₂ Concentration Range | 0.1–1% v/v |
| Gas Delivery Method | Pressurized Cylinder System |
| Chamber Interior Material | PVC Plastic Sheet |
| Exterior Casing Material | Reinforced PVC Rigid Board |
| Viewing Window | Transparent Impact-Resistant Acrylic Lid |
| Sealing Method | Water-Tight Gasket Seal |
| Heating Method | Immersed Water-Bath Heater in Inner Tank |
| Standard Compliance | GB/T 9789–1988, DIN 50018, ISO 6988 (referenced) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LHH-150GSP, LHH-250GSP |
| Internal Dimensions (L×W×H) | 600×405×620 mm |
| Temperature Range | 0–65°C (dark), 10–65°C (light) |
| Humidity Range | 40–98% RH |
| Illumination | 0–6000 lx (adjustable) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Temperature Sensor | Imported Swiss PT100 Platinum Resistance Thermometer |
| Humidity Sensing | Direct-reading PT100-based RH sensor |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | YWX-10 |
| Temperature Range | RT+10 to 55 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL/80 cm²·h |
| Chamber Construction | Integral FRP (Fiberglass-Reinforced Plastic) Molded Body |
| Lid Material | Transparent PVC |
| Control System | High-Precision PID Controller (±0.1 °C accuracy) |
| Spray Method | Tower-Type Atomization System |
| Safety Protections | Low-Water Detection, Over-Temperature Cut-off, Phase Failure Protection |
| Sealing | Water-Sealed Chamber Design |
| Brand | MKN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | YWX Series |
| Price | USD 3,100 (FOB Jiangsu) |
| Temperature Range | RT+10–55 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Saturated Air Pressure | 0.8–2.0 ± 0.01 kg/cm² |
| Test Chamber Temp (Neutral Salt Spray) | 35 ± 1 °C |
| Test Chamber Temp (Copper-Accelerated Acetic Acid Salt Spray, CASS) | 50 ± 1 °C |
| Air Saturator Temp (NSS) | 47 ± 1 °C |
| Air Saturator Temp (CASS) | 63 ± 1 °C |
| Chamber Volumes | 100 L, 250 L, 500 L, 1000 L, 2000 L |
| Water Reservoir Capacity | 15–40 L |
| Power Supply | 220 V / 50 Hz or 380 V / 50 Hz (3-phase, 4-wire) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Program Groups | 120 |
| Total Program Segments | 1,200 |
| Max Repetitions per Command | 999 |
| Segment Duration Range | 0–99 h 59 min |
| Power-Failure Recovery | Yes, auto-resume with state retention |
| Real-Time Graphical Curve Display | Yes |
| PID Parameter Sets | 9 independent groups |
| Saturation Chamber | Heated, oil-filtered, humidity-conditioned air supply |
| Spray Mode | Pneumatic atomization (continuous or intermittent) |
| Compressed Air Control | Regulated via precision pressure-reducing valve + solenoid shut-off valve |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 21,500 (FOB) |
| Internal Chamber Dimensions | 600 × 450 × 400 mm / 900 × 600 × 500 mm / 1200 × 840 × 500 mm (W×D×H) |
| Chamber Material | 5 mm PVC board (heat-resistant up to 85°C) |
| Lid Material | 5 mm impact-resistant acrylic |
| Test Standards Compliant | ASTM B117, ISO 9227, JIS Z2371, CNS 12207, GB/T 10587 |
| Salt Spray Modes | Neutral Salt Spray (NSS), Acetic Acid Salt Spray (AASS), Copper-Accelerated Acetic Acid Salt Spray (CASS) |
| Test Chamber Temp Control | 35°C ±1°C (NSS/AASS), 50°C ±1°C (CASS) |
| Saturated Air Chamber Temp Control | 47°C ±1°C (NSS/AASS), 63°C ±1°C (CASS) |
| Timer Range | 0–999.9 h (Italian-made digital timer) |
| Water Supply System | Dual-mode (automatic + manual) for chamber and saturator |
| Temperature Controller Resolution | ±0.3°C (LCD digital PID controller) |
| Pressure Regulator | Precision air filter + pressure gauge (0–2.5 kg/cm², accuracy ±0.01 kg/cm²) |
| Safety Protections | Low-water cutoff, overtemperature shutdown, salt-solution level alarm, visual warning indicators |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Power Supply | AC 220 V ±10% / 50 Hz or AC 380 V ±10% / 50 Hz |
| Operating Ambient | 5–30 °C, ≤85% RH |
| Chamber Construction | Fiberglass-Reinforced Polymer (FRP) Monolithic Body |
| Sealing Method | Water-Seal Lid Design |
| Safety Protections | Overtemperature, Leakage Current, Short-Circuit, Low-Water Level, Overcurrent, End-of-Test Auto-Shutdown |
| Standard Accessories | V-Type Sample Racks (2 pcs), Dual Nozzles, Calibration Funnel & Graduated Cylinder, Water Filter on Brine Suction Line, Preheated Brine Delivery System |
| Compliance Standards | GB/T 2423.17–2022, IEC 60068-2-11, ASTM B117, ISO 9227, MIL-STD-810H (Method 509.6), DIN 50021 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Chamber Volume | 3–116 m³ |
| Temperature Range | RT+10 to 55 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Chamber Construction | 8 mm High-Temperature Resistant PVC Panels |
| Saturated Air Tank | SUS304 Stainless Steel with Level Indicator |
| Heating Element | Titanium Alloy Immersion Heater |
| Compliance | ASTM B117, ISO 9227, IEC 60068-2-11, DIN 50021, JIS Z2371, GB/T 2423.17 |
| Temperature Range | RT+10°C to 50°C |
|---|---|
| Humidity Range | 85–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| SO₂ Generation Method | Compressed Gas Cylinder |
| SO₂ Concentration Range | 0.05–1.0% v/v |
| Compliance | ASTM B117, ISO 6988, IEC 60068-2-60, GB/T 2423.33 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Power Supply | 380 VAC, 3-phase, 100 A |
| Operating Time Timer | 0–999 hours |
| Control Interface | Touchscreen HMI with RS232 port |
| PID Control | 9 independent sets with auto-tuning |
| Saturation Tower | Heated, oil-removal, humidity-conditioned air supply |
| Spray Mode | Pneumatic atomization (continuous or intermittent) |
| Compressed Air Regulation | Precision pressure-reducing valve + solenoid shutoff valve |
| Safety Protections | Low-water-level, over-temperature, over-current, visual alarm indicators |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Compliance | ASTM B117, ISO 9227, IEC 60068-2-11, GB/T 2423.17, JIS Z 2371, DIN 50021 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 60°C ±1°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±1.0°C |
| Salt Spray Deposition Rate | 1–2 mL/80 cm²·h |
| Salt Solution Temperature | RT+10°C to 60°C ±1°C |
| Salt Concentration | 5.0 ±0.5% (w/w) NaCl |
| Humidity Range | 30–98% RH (adjustable) |
| Chamber Internal Dimensions (W×D×H) | 2000 × 1000 × 500 mm |
| Chamber External Dimensions (W×D×H) | 2400 × 1400 × 1000 mm |
| Test Specimen Tilt Angles | 15° and 30° (standard), ≥50 specimens accommodated at 30° |
| Construction Materials | 8 mm HCPVC inner chamber & lid |
| Air Supply | External compressed air source required (not included) |
| Operation Mode | Continuous or cyclic |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Compliance Standards | ASTM B117, ISO 9227, IEC 60068-2-11, JIS Z 2371, GB/T 2423.17 |
| Chamber Capacities (L) | 108 |
| Internal Dimensions (W×D×H, cm) | 60×45×40 |
| External Dimensions (W×H×D, cm) | 110×60×118 |
| Temperature Range | 35°C ± 1°C (salt fog), 15–60°C (dry/humidity cycles) |
| Humidity Control | 30–98% RH (optional) |
| Spray Nozzle Pressure | 0.8–1.2 bar (dual-stage pressure regulation) |
| Salt Solution Concentration | 5.0 ± 0.1% NaCl (by weight) |
| Saturation Tank Material | 3 mm SUS#304 stainless steel |
| Chamber Lining | 8 mm heat-resistant HC-PVC |
| Heating Element | Titanium alloy immersion heater |
| Circulation Fan | Oriental Motor multi-wing centrifugal blower |
| Corrosion-Resistant Pump | Ebara or ITT series |
| Control Interface | LCD with RS232 communication |
| Safety Protections | Low water level, overtemperature, motor overload, spray blockage detection |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | OK-FH-120 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-misting Method | Pneumatic Air-Pressure Exhaust |
| Salt Fog Deposition Rate | ~1.0–2.0 mL/80 cm²·hr (ASTM B117 compliant range) |
| Temperature Range Options | A: 0°C to +80°C |
| B | −20°C to +80°C |
| C | −40°C to +80°C |
| Humidity Range | 10%–98% RH (at ≥+10°C) |
| Control Accuracy | ±0.5°C (temp), ±2.5% RH (humidity), ±0.1 mL/80 cm²·hr (spray deposition) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | OK-FH-121 |
| Salt Spray Method | Air-Atomized Nozzle System (OK-FH-120 Compatible) |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal | Pneumatic Air-Blow Exhaust |
| Salt Fog Settlement | ~1.0–2.0 mL/80 cm²·hr (ASTM B117 compliant range) |
| Temperature Range Options | A: 0–80°C |
| B | −20–80°C |
| C | −40–80°C |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (D×W×H) | 60×90×50 cm |
| External Dimensions (D×W×H) | 106×155×121 cm |
| Temperature Range | RT+10°C to 55°C |
| Humidity | ≥93% RH |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Fog Deposition Rate | 1–2 mL/80 cm²/h |
| Spray Mode | Continuous or Cyclic (Selectable) |
| Sample Rack | Dual-layer, Adjustable Tilt (15°–30°) |
| Compressor Requirement | V-0.013/12.5 (User-supplied) |
| Discharge Pressure | 1.25 MPa |
| Air Flow | 0.13 m³/min |
| Heating System | Water-jacketed with Titanium-sheathed NiCr Far-infrared Heater |
| Chamber Material | PVC Plastic Board (UV-stabilized, acid/salt-resistant) |
| Lid Material | Transparent Impact-resistant Polycarbonate |
| Sealing | Water-sealed Lid-to-Body Interface |
| Compliance | GB/T 2423.17, GB/T 10587, GJB 150.11A, DIN 50021, ISO 9227 (Neutral Salt Spray NSS), ASTM B117 |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Chamber Internal Dimensions (W×D×H) | 900 × 600 × 500 mm |
| External Dimensions (W×D×H) | 1420 × 780 × 1280 mm |
| Salt Spray Modes | NSS (ASTM B117), ACSS, CASS (ISO 9227) |
| Test Chamber Temp. Range | 35 ±1 °C (NSS/ACSS), 50 ±1 °C (CASS) |
| Saturated Air Tank Temp. | 47 ±1 °C (NSS/ACSS), 63 ±1 °C (CASS) |
| Air Supply Pressure | 1 kgf/cm² (two-stage regulation) |
| Safety Systems | Low-water cutoff, overtemperature shutdown, low-salt solution alarm, visual/audible warning indicators |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-FH-9.00 |
| Spray Mode | Continuous Atomization |
| Nozzle Pressure | 0.7–1.0 kgf/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (16-h average) |
| Temperature Range | −10°C to +80°C |
| Humidity Range | 20–98% RH |
| Temp. & Humidity Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Chamber Temp. (NSS) | 35±1°C |
| Chamber Temp. (CASS) | 50±1°C |
| Saturation Tower Temp. (NSS) | 47±1°C |
| Saturation Tower Temp. (CASS) | 63±1°C |
| Salt Solution Temp. | 35±1°C or 50±1°C |
| NaCl Concentration | 5.0 wt% (with optional 0.26 g/L CuCl₂·2H₂O for CASS) |
| Compressed Air Pressure | 1.00±0.01 kgf/cm² |
| Refrigeration System | Hermetic Dual-stage Low-Noise Compressor (R404A/R23) |
| Controller | 7-inch Color LCD Touchscreen (OYO U-8256P, bilingual EN/CN) |
| Program Capacity | 140 Patterns × 1400 Steps |
| Loop Repetition | 1–999 cycles per segment |
| Segment Duration | 0–999 h 59 min |
| Power Failure Recovery | Yes |
| Interface | RS232 |
| Power Supply | 220V±5% / 50±0.5 Hz or 380V±5% / 50±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +10°C to 60°C ±1°C |
| Temperature Uniformity | ±1.0°C |
| Salt Solution Concentration | 5.0 ±0.5% (w/w) NaCl |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Humidity Range | 30–98% RH (adjustable) |
| Internal Chamber Dimensions (W×D×H) | 900 × 600 × 500 mm |
| External Dimensions (W×D×H) | 1500 × 1300 × 1000 mm |
| Salt Reservoir Capacity | 40 L (PVC-lined) |
| Programmable Steps | 1200 segments across 120 program groups |
| Segment Duration | 0–99 h 59 min |
| PID Control | 9 independent sets with auto-tuning |
| Compliance | GB/T 2423.17–1993, GB/T 5170.8–1996, GB/T 10587–2006 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Internal Dimensions (D×W×H) | 900 × 600 × 500 mm |
| External Dimensions (D×W×H) | 1410 × 880 × 1280 mm |
| Heating Power | 1.3–1.8 kW |
| Temperature Range | +5°C to +55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic Programmable |
| Timer Range | 1 sec to 999 hours, minutes, seconds |
| Heating System | U-shaped titanium alloy high-speed immersion heater |
| Temperature Controller | Intelligent PID microcomputer controller with ±0.1°C control accuracy |
| Sensor | PT100 platinum resistance thermometer |
| Viewing Window | Full-transparent impact-resistant acrylic lid with water-sealed gasket |
| Sealing | Water-trap sealing between lid and chamber body |
| Lid Actuation | Pneumatic support struts |
| Interior Lining | PVC plastic board |
| Exterior Casing | Reinforced rigid PVC sheet (UV-stabilized, corrosion-resistant) |
| Included Accessories | One SO₂ gas cylinder (standard 40L, 15 MPa rated), regulator, and delivery tubing |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Chamber Internal Dimensions (W×D×H) | 900 × 600 × 500 mm |
| External Dimensions (W×D×H) | 1420 × 780 × 1280 mm |
| NSS Test Temperature | 35 ± 1 °C |
| SATURATED AIR BUCKET TEMP (NSS) | 47 ± 1 °C |
| CASS Test Temperature | 50 ± 1 °C |
| SATURATED AIR BUCKET TEMP (CASS) | 63 ± 1 °C |
| Air Supply Pressure | 1 kg/cm² (two-stage adjustable) |
| Safety Features | Low-water-level cutoff, Overtemperature cutoff, Visual/audible alarm system, Low-salt-solution warning indicator |
| Note | Compressed air source and deionized water supply must be provided by user |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | OK Instruments |
| Model | OK-FH-90.0 |
| Spray Mode | Continuous Atomization |
| Salt Solution Delivery Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Compression Exhaust |
| Salt Fog Deposition Rate | ~1.0–2.0 mL/80 cm²·hr (per ASTM B117) |
| Temperature Range Options | A: 0°C to +80°C |
| B | −20°C to +80°C |
| C | −40°C to +80°C |
| Humidity Range | 20–98% RH (at applicable temperature bands) |
| Compliance | Designed to support ASTM B117, ASTM G85 Annexes (A1–A5), ISO 9227, IEC 60068-2-11 & -52, GMW 14872, SAE J2334, VCS 1027,149 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | OK-FH-90.00 |
| Spray Mode | Continuous Atomization |
| Salt Solution Delivery Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Pneumatic Air-Scavenging Exhaust |
| Salt Fog Deposition Rate | ~1.0–2.0 mL/80 cm²·hr (ASTM B117-compliant range) |
| Temperature Range Options | A: 0–80°C |
| B | −20–80°C |
| C | −40–80°C |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-FH-90.000 |
| Spray Mode | Continuous Atomization |
| Salt Solution Delivery Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Fog Deposition Rate | ~1.0–2.0 mL/80 cm²·hr (per ASTM B117) |
| Temperature Range Options | A: 0°C to +80°C |
| B | −20°C to +80°C |
| C | −40°C to +80°C |
| Humidity Range | 20–98% RH (at applicable temperature bands) |
| Compliance Basis | ASTM B117, ASTM G85 Annex A5 (CCT-I), ISO 9227, GMW 14872, SAE J2334, IEC 60068-2-11 & -52 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-FH-90.001 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Deposit Rate | ~1.0–2.0 mL/80 cm²·hr (per ASTM B117 calibration) |
| Temperature Range Options | A: 0°C to +80°C |
| B | −20°C to +80°C |
| C | −40°C to +80°C |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-FH-91 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Fog Deposition Rate | ~1.0–2.0 mL/80 cm²·hr (ASTM B117-compliant range) |
| Temperature Range | Configurable Options — A: 0°C to +80°C |
| B | −20°C to +80°C |
| C | −40°C to +80°C |
| Humidity Range | 20–98% RH (at applicable temperature bands) |
| Compliance | ASTM B117, ASTM G85 Annex A5 (CCT-I), ISO 9227, IEC 60068-2-11 & -52, GMW 14872, SAE J2334 |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 50°C |
| Humidity Range | 85–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| Salt Solution Concentration | 0.1–1% v/v |
| Spray Method | Compressed Air Atomization (PYREX Glass Nozzle) |
| Saturated Air Tank Control | Henry’s Law-Based Heating & Humidification |
| Test Modes | Continuous Salt Spray (ASTM B117), Cyclic Salt Spray (GB/T 10587, ISO 9227), NSS/ASS/CASS Protocols |
| Chamber Models | OK-SH-60 (850×1300×600 mm), OK-SH-80 (850×1600×600 mm), OK-SH-120 (900×2000×600 mm) |
| Brand | OK Instrumentation |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +5°C to 55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic |
| Test Timer | 1–999 s/min/h adjustable |
| Power Consumption | 1.3–1.8 kW (model-dependent) |
| Compliance | ASTM B117, ISO 9227, JIS Z2243, GB/T 2423.17 |
| Chamber Construction | Monolithic FRP body with high-temp fusion welding |
| Safety Features | Low-water cutoff, over-temperature cutoff, low-salt-level alarm, visual/audible warning system |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Internal Dimensions (W×D×H) | 900 × 600 × 500 mm |
| External Dimensions (W×D×H) | 1420 × 780 × 1280 mm |
| NSS Test Temp | 35 ± 1 °C |
| SATURATION AIR TANK TEMP (NSS) | 47 ± 1 °C |
| CASS Test Temp | 50 ± 1 °C |
| SATURATION AIR TANK TEMP (CASS) | 63 ± 1 °C |
| Air Supply Pressure | 1 kg/cm² (two-stage regulation) |
| Safety | Low-water cutoff, overtemperature cutoff, low-brine-level alert, visual alarm indicators |