Second-hand Analytical Instruments
Filter
Showing 1–30 of 43 results
| Brand | AB SCIEX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB SCIEX Triple Quad 6500+ + Shimadzu Nexera LC-40BX3 |
| Quotation | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 1260 Infinity II |
| Instrument Category | Liquid Chromatography (HPLC) |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Compliance | Fully refurbished to meet Agilent’s certified pre-owned standards |
| Software | OpenLAB CDS (ChemStation or EZChrom compatible) |
| Configuration | Quaternary pump, DAD or VWD detector, thermostatted autosampler, column compartment |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890 Plus GC + 5973 MSD |
| Configuration | GC-MS System for VOC/SVOC Quantification per GB/T 23986.2–2023 |
| Condition | Professionally Refurbished & Functionally Verified |
| Compliance | Fully Compatible with ASTM D6886, ISO 11890-2, and US EPA Method 8260D workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7697A |
| Sample Capacity | Up to 111 vials (auto-sampler mode) |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Oven Temperature Range | Ambient to 200 °C |
| Transfer Line & Valve Temperature Range | Ambient to 200 °C |
| Injection Mode | Six-port valve with fixed-volume loop |
| Carrier Gas Control | Electronic Pressure Control (EPC) for He, N₂, H₂ |
| Software Compatibility | Agilent OpenLAB CDS and ChemStation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Key | Brand: Agilent |
|---|---|
| Model | 7890B GC + Entech 7100 |
| Origin | Shanghai, China (Distributed by Junqi Instruments) |
| Detector | FPD (Sulfur-Selective) |
| Column | GS-GasPro, 30 m × 0.32 mm |
| Preconcentration System | Entech 7100 + 7032 Autosampler |
| Software | Agilent GC ChemStation + Entech Preconcentrator Control Suite |
| Warranty | 1 year |
| Operational Age | 3 years |
| Compliance | EPA TO-14, TO-15, ASTM D5504, USP <467> |
| Sample Matrix | Ambient air, canister/bag samples, humid up to 100% RH |
| Detection Range | Sub-ppbv for H₂S, CH₃SH, DMS, COS, CS₂ |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977B |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Vacuum System | High-Performance Turbomolecular Pump |
| Ion Source | Dual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel) |
| Mass Analyzer | Gold-Plated Quartz Quadrupole with Turner-Kruge Lenses |
| Mass Range | 1.6–1050 u (0.1 u increments) |
| Resolution | Unit Mass Resolution |
| Mass Stability | ≤0.10 u / 48 h |
| Full-Scan Sensitivity (EI) | ≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan) |
| SIM Sensitivity (EI) | ≥10:1 S/N for 20 fg OFN |
| Max Scan Rate | 12,500 u/s (1 ms dwell in SIM) |
| Dynamic Range | 10⁶ |
| SIM Capacity | 100 groups, up to 60 ions/group |
| GC Oven Temp Range | 4 °C above ambient to 450 °C |
| Max Ramp Rate | 120 °C/min |
| Temperature Stability | <0.01 °C per 1 °C ambient change |
| Programmable Temperature Zones | ≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C |
| EPC Pressure Control Accuracy | ±0.001 psi |
| Split/Splitless Inlet | Up to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range |
| Auto-sampler | 16-position (standard), optional 150-position tray |
| Detectors Included | FID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s) |
| Compliance | Fully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1100 |
| Warranty | 1 Year |
| Product Category | Chromatography System |
| Instrument Type | Liquid Chromatograph |
| Refurbishment Standard | Agilent Certified Refurbished |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1290 Infinity LC |
| Product Category | Chromatography |
| Warranty | 1 Year |
| Refurbishment Standard | Agilent Certified Refurbished Program |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Country of Origin | Imported |
| Model | 5973N |
| Product Category | Mass Spectrometer |
| Warranty | 1 Year |
| Instrument Model | 5973N |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 6410 |
| Product Type | Mass Spectrometer |
| Warranty | 1 Year |
| Certification | Agilent Certified Refurbished Program |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7000C GC/MS |
| Product Category | Mass Spectrometer |
| Warranty Period | 1 Year |
| Instrument Model | 7000C GC/MS |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 7200 Refurbished |
| Product Type | Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF) |
| Warranty | 1 Year |
| Certification | Agilent Certified Refurbished Program |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | Cary 60 |
| Product Type | Spectrometer |
| Warranty | 1 Year |
| Instrument Serial Verification | Full OEM Functional & Performance Qualification |
| Refurbishment Standard | Agilent Certified Refurbishment Program |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Instrument Type | Imported Used GC |
| Model | 6890N |
| Warranty | 12 months |
| Service Coverage | Global Agilent Field Service Network |
| Software Compatibility | Fully compatible with OpenLab CDS (v2.3+), ChemStation (Rev. E.02.02.1400+) |
| Regulatory Compliance | Designed to support GLP/GMP environments |
| Firmware | Updated to latest certified revision at time of refurbishment |
| Physical Condition | New chassis, refurbished internal modules, factory-cleaned flow paths, recalibrated detectors and injectors |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GC6890 |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets ASTM D3606, ISO 17025-relevant operational standards |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD |
| Column Compatibility | Up to 0.53 mm ID capillary or packed columns |
| Oven Temperature Range | 4°C to 450°C (programmable) |
| Injector Types | Split/Splitless, Cool-on-Column, PTV |
| Data System | Compatible with Agilent ChemStation (Rev. A.10.x or later) |
| Regulatory Readiness | Audit-trail capable |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Agilent VK7025 Dissolution Tester |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Age | 4–5 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Second-hand Dissolution Testing System |
| Model | VK7025 |
| Age | 4–5 years |
| Regulatory Compliance | USP <711>, EP 2.9.3, JP XVII, ChP 0931 |
| Sample Capacity | 6-vessel |
| Vessel Configurations | Basket (USP Apparatus 1) & Paddle (USP Apparatus 2) |
| Temperature Control | Independent vessel-level PT100 probes with ±0.2 °C accuracy |
| Automation Features | Motorized sampling arm, programmable DDM (Drug Delivery Module), TruCenter™ magnetic cup alignment, dome-shaped anti-evaporation lids |
| Software Compatibility | Agilent Dissolution Workstation (FDA 21 CFR Part 11 compliant with audit trail, electronic signature, and user access control) |
| Brand | Antek by PAC |
|---|---|
| Origin | USA |
| Model | 9000VN |
| Application | Elemental Analysis (Total Nitrogen) |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Includes analyzer unit and dedicated workstation PC |
| Compliance | Designed to meet ASTM D5762, D4629, and ISO 14851/14852 standards for total nitrogen determination in liquid hydrocarbons and petrochemicals |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7900HT |
| Instrument Age | 6–8 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per manufacturer specifications |
| Software | SDS 2.4 or later (compatible with Windows-based analysis workstations) |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 300 |
| Usage Duration | <1 year |
| Imaging Modalities | UV (254/302 nm), Blue Light (470 nm), White Light (LED transilluminator & reflected light), Chemiluminescence |
| Sensitivity | Sub-femtogram detection for HRP-based chemiluminescent substrates |
| Interface | Integrated 12.1″ capacitive touchscreen |
| Software | AzureSpot™ v6.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP-ready workflow templates |
| Upgradability | Field-upgradable to Azure C400/C500/C600 platform architecture |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 450 GC |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Age | >10 Years |
| Pump Flow Rate | 0.5–4.0 mL/min |
| Max Pump Pressure | 4000 psi (27.5 MPa) |
| Conductivity Detector Range | 0–1700 µS |
| Temperature Compensation | 1.5–1.9%/°C |
| Detector Cell Volume | 1.25 µL |
| Operating Temperature | 10–40°C |
| Dimensions (H×W×L) | 60 × 30 × 40 cm |
| Weight | ~40 kg |
| Power Input | 100 V/50 Hz, 115 V/60 Hz, or 220–240 V/50 Hz |
| Brand | OtO |
|---|---|
| Origin | Taiwan |
| Model | SW2860-050 |
| Wavelength Range | 900–1700 nm |
| Detector | 256-pixel InGaAs linear array |
| Cooling | Thermoelectric (TE) |
| Usage Duration | 2 years |
| Warranty | ≥3 years |
| Condition | Refurbished, Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | NexION 300Q |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ASTM D5673 and ISO/IEC 17025-aligned protocols |
| Software | Syngistix v3.5 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Detection Limit Performance | Sub-femtogram-level sensitivity for key isotopes (e.g., ⁹Be, ¹¹⁵In, ²⁰⁸Pb) under optimized conditions |
| Vacuum System | Dual-stage turbomolecular pumping with integrated cryo-trapping capability |
| Ion Optics | Triple-cone interface + three quadrupole mass filters (Q1: ion/molecule separation |
| Q2 | universal cell reaction/collision zone |
| Q3 | high-resolution mass filtering) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Spectrum ONE |
| Instrument Type | Fourier Transform Infrared (FTIR) Spectrometer |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Includes Spectrum ONE main unit, Spectrum Spotlight FTIR Imaging System, and dedicated PC with proprietary software |
| Compliance | Fully refurbished and performance-verified per ASTM E1421–22 standard for FTIR instrument qualification |
| Software | Spectrum v6.x (with full license transfer eligibility) |
| Detector | Dual-channel DTGS/KBr beam splitter configuration |
| Spectral Range | 4000–400 cm⁻¹ (standard) |
| Resolution | Adjustable down to 0.5 cm⁻¹ |
| Scan Speed | Up to 20 kHz mirror velocity |
| Data Format | Compatible with JCAMP-DX, ASCII, and HDF5 export |