| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DL-1044 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6,000 rpm |
| Max RCF | 5,037 × g |
| Max Capacity | 5 × 96 mL (horizontal rotor) |
| Dimensions (L×W×H) | 580 × 485 × 420 mm |
| Construction | Dual-layer steel housing with stainless-steel centrifuge chamber |
| Drive System | Maintenance-free AC brushless frequency-controlled motor |
| Control Interface | Microprocessor-based touch keypad with LED display |
| Safety Features | Dual interlocked door latch, automatic imbalance detection, overspeed protection, audible alarm |
| Programmability | User-defined protocols with independent setpoints for RCF, speed, and time |
| Operational Mode | Real-time parameter adjustment during non-programmed runs |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DL-1044R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5500 rpm |
| Max RCF | 5400 × g |
| Max Capacity | 4 × 750 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (L×W×H) | 702 × 590 × 890 mm |
| Drive System | Brushless AC Frequency-Controlled Motor |
| Rotor Compatibility | Horizontal, microplate, and fixed-angle rotors |
| Safety Features | Dual interlocked door lock, automatic imbalance detection, overspeed protection, acoustic alarm |
| Control Interface | LED-displayed parameters (speed, RCF, time, temperature), touch keypad, 20 programmable protocols |
| Acceleration/Deceleration | 15-step selectable ramp rates |
| Special Functions | “At Set RCF” timing mode, short-spin (pulse) mode, real-time parameter adjustment during non-programmed runs |
| Compliance | Designed per IEC 61010-2-020 (Safety Requirements for Centrifuges), supports GLP-compliant operation with audit-ready parameter logging |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | DL-2018H |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 18,800 rpm) |
| Max. RCF | 26,870 × g |
| Max. Capacity | 10 mL × 12 |
| Rotor Recognition | Magnetic auto-identification |
| Acceleration/Deceleration | 15 steps each |
| Timer Range | 1 s – 99 h 59 min 59 s |
| Speed Accuracy | ±10 rpm |
| Temperature Rise | <10 °C after 20 min operation |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Power Consumption | 400 W |
| Dimensions (L×W×H) | 426 × 322 × 340 mm |
| Net Weight | 28 kg |
| Rotor Compatibility | H0.136, H0.232, H0.512, H0.524, H0212, H0224, H0512, H1012 |
| Sterilization | Autoclavable at 121 °C for ≥2 h |
| Safety | Dual interlock door, imbalance detection & auto-stop, soft-brake (SOFT mode), overspeed protection |
| Software Features | Programmable protocols (20 presets), differential centrifugation (DCT) mode (5 dedicated slots), real-time parameter display (speed, RCF, time, acceleration/deceleration profile), on-the-fly parameter adjustment |
| Brand | Duling |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DL-300S |
| Ultrasonic Power | 300 W |
| Ultrasonic Frequency | 30 kHz |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | DL-3021H |
| Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm) |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 30,409 × g |
| Maximum Capacity | 6 × 100 mL |
| Dimensions (L×W×H) | 450 × 370 × 410 mm |
| Rotor Autoidentification | Magnetic |
| Sterilization | 121 °C, ≥2 h autoclave-compatible |
| Acceleration/Deceleration Profiles | 15-step selectable |
| Soft-Brake Function | Yes |
| Door Locking | Dual interlocked safety system |
| Control Interface | Full-color TFT touchscreen with real-time parameter display |
| Communication Option | RS-485 interface (optional) |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DL-3021HR |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor |
| Separation Level | Cellular & Bacterial |
| Maximum Capacity | 6 × 100 mL |
| Maximum Speed | 23,000 rpm |
| Maximum RCF | 36,795 × g |
| Dimensions (L×W×H) | 570 × 590 × 490 mm |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DL-3024HR |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor |
| Separation Class | Cellular & Bacterial |
| Maximum Capacity | 4 × 750 mL |
| Maximum Speed | 24,000 rpm |
| Maximum RCF | 40,217 × g |
| Dimensions (L×W×H) | 720 × 590 × 890 mm |
| Brand | Dynamica |
|---|---|
| Origin | Germany |
| Model | V30R |
| Instrument Type | Benchtop High-Speed Refrigerated Centrifuge |
| Speed Range | 200–30,000 rpm (10 rpm increments) |
| Max RCF | 66,410 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range | −20 °C to +40 °C (1 °C increment) |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Steps | 10/10 |
| Noise Level | <60 dB(A) |
| Dimensions (L×D×H) | 715 × 510 × 420 mm |
| Net Weight | 91 kg |
| Power Supply | 230 V, 50/60 Hz |
| Drive System | Brushless Induction Motor |
| Control System | Microprocessor-Based |
| Rotor Auto-Recognition | Yes (with overspeed protection) |
| Imbalance Detection | Yes |
| Timer Range | 30 s – 99 h 59 min + HOLD |
| Speed/RCF Conversion | Yes |
| Programmable Methods | 99 |
| Display | LCD |
| Brand | Dynamica |
|---|---|
| Model | VELOCITY 14/14R Pro |
| Type | Refrigerated Benchtop Centrifuge |
| Max Speed | 14,000 rpm |
| Max RCF | 21,780 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Acceleration/Deceleration | 9-step programmable |
| Unbalance Detection | Non-contact electronic |
| Rotor Recognition | Automatic |
| Drive | Brushless Induction Motor |
| Noise Level | <58 dB(A) (14R), <53 dB(A) (V14) |
| Dimensions (W×D×H) | 560 × 500 × 380 mm (14R), 340 × 490 × 380 mm (V14) |
| Net Weight | 60 kg (14R), 40 kg (V14) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A (14R), 8 A (V14) |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | Velocity 17/17R Pro |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 17,000 rpm |
| Max RCF | 25,507 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W × D × H) | 560 × 500 × 380 mm |
| Rotor Compatibility | 16 interchangeable rotors (angle, fixed-angle, swing-out) |
| Safety Certifications | IEC 61010-1, EN 61326-1 |
| Compliance | GLP-ready, supports audit trails and user access control |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | VELOCITY 18R |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifugation |
| Configuration | Horizontal Rotor System |
| Max. Capacity | 4 × 300 mL |
| Max. Speed | 18,000 rpm |
| Max. RCF | 30,318 × g |
| Dimensions (L×W×H) | 730 × 610 × 380 mm |
| Net Weight | 100 kg |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Noise Level | <58 dB(A) |
| Acceleration | 9 levels |
| Deceleration | 10 levels |
| Rotor Recognition | Automatic, non-contact |
| Imbalance Detection | Non-contact electronic sensing |
| Speed Range | 300–18,000 rpm (100 rpm increments) |
| Speed Accuracy | ±20 rpm |
| Timer | 1 min – 99 h 59 min + Hold function |
| Memory | 9 programmable protocols |
| Drive | Brushless induction motor |
| Display | Backlit LCD panel |
| Pre-cool Function | Yes |
| Sample Temperature Monitoring | Real-time rotor-based temperature measurement |
| Brand | Dynamica |
|---|---|
| Model | Velocity 18R Plus |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 18,000 rpm |
| Max RCF | 30,318 × g |
| Max Capacity | 4 × 400 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W×D×H) | 670 × 625 × 380 mm |
| Drive System | Brushless DC Motor |
| Rotor Recognition | Automatic RFID-based |
| Acceleration/Deceleration Profiles | 10 selectable rates |
| Timer Modes | Fixed time, ramp-to-speed, hold-at-speed |
| Compliance | ISO 13485 design principles, GLP-ready audit trail logging, FDA 21 CFR Part 11–compatible software options available |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | Velocity15/15R Pro |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 22,302 × g |
| Max Capacity | 50 mL (e.g., 10 × 5 mL conical tubes) |
| Temperature Range | −20 °C to +40 °C |
| Speed Increment | 100 rpm |
| Acceleration/Deceleration | 2-step selectable |
| Timer Range | 1–99 min |
| Noise Level | <53 dB(A) |
| Rotor Auto-ID | Yes |
| Rotor Compatibility | Fixed-angle rotors for 0.2 mL PCR tubes (32×), 2 mL microtubes (24×), 5 mL conical tubes (10×), and cryovials |
| Speed/RCF Conversion | Built-in |
| Display | Real-time progress bar, error code diagnostics |
| Control | Single-knob intuitive interface |
| Instant Spin Function | Yes |
| Brand | DYYB |
|---|---|
| Origin | Shanghai, China |
| Model | DH-2400R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 300–24,000 rpm |
| Max RCF | 39,900 ×g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | −20 °C to +40 °C |
| Refrigeration System | CFC-free compressor-based cooling |
| Power Supply | AC 230 V, 50–60 Hz |
| Motor Power | 550 W |
| Cooling Power | 370 W |
| Dimensions (H×W×D) | 370 × 610 × 520 mm |
| Weight (empty) | 62 kg |
| Noise Level (at max speed) | ≤58 dB(A) |
| Acceleration/Deceleration Time | 26 s each |
| Rotor Recognition | Yes |
| Safety Compliance | EN 61326 |
| Display | 5.1″ German-sourced LCD with real-time parameter monitoring |
| Control Interface | Single-knob rotary encoder + dedicated Start/Stop/Lid buttons |
| Programmability | 10 pre-stored protocols, 10-step acceleration/deceleration profiles |
| Rotor Materials | Anodized ultra-hard aluminum alloy, autoclavable (≥121 °C, unlimited cycles) |
| Rotor Types | Fixed-angle (including PCR, microtube, conical, round-bottom), swing-bucket (Biosafe), and microplate carriers |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ENV-6 |
| Pricing | Available Upon Request |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200B |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 500 mL × 3 |
| Extraction Cycle Time | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Positions | 3 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 30 W |
| Net Weight | 15.7 kg |
| Operating Principle | Mechanical Stirring-Assisted Phase Separation |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200C |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 1000 mL × 3 |
| Extraction Time Range | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Throughput | 3 independent stations |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 20 W |
| Net Weight | 15.7 kg |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec 8000 |
| Extraction Chamber Volume | 65 mL |
| Receiver Flask Capacity | 40–110 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 or 12 samples per batch |
| Solvent Recovery Efficiency | up to 80% |
| Safety Features | Automatic solvent leak detection, auto-empty alert for recovery tank, self-diagnostic startup sequence |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec™ 255 |
| Extraction Chamber Volume | 30 mL |
| Receiver Flask Volume | 70–90 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 samples per batch |
| Solvent Consumption per Sample | ~16 mL |
| Solvent Recovery Rate | up to 80% |
| Heating Time (20 °C → 280 °C) | 7–9 min |
| Typical Extraction Duration | 40–60 min |
| Repeatability | ±1% RSD |
| Sample Mass Range | 0.5–15 g |
| Sample Cup Dimensions | 33 × 80 mm (approx. 65 mL capacity) |
| Measurement Range | 0.1–100% fat content |
| Brand | SIENCE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLS600P-MX |
| Price | USD 8,100 (FOB Jiangsu) |
| Chamber Dimensions | 600 × 600 × 800 mm (L×W×H) |
| Max Load Capacity | 50 kg (uniformly distributed) |
| Pressure Washing Range | 0.1–0.5 MPa |
| Ultrasonic Frequency | 40 kHz, adjustable power output |
| Flow Rate (Rinse Mode) | 1.0–5.5 L/min (with 2.5 mm nozzle) |
| Filtration Stages | Dual-stage absolute filtration — 0.2 µm (pre-wash supply) and 1.0 µm (post-extraction recirculation) |
| Filter Membrane Compatibility | Φ47–50 mm |
| Airflow Class | ISO Class 5 (100-grade) or ISO Class 6 (1,000-grade) laminar flow in wash chamber |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | <70 dB(A) |
| Net Weight | ~400 kg |
| Compliance Standards | VDA 19.1:2015, ISO 16232:2018, ASTM D7252, USP <788> (particle counting), GLP/GMP-aligned operational logging |
| [Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-5000 |
| Automation Level | Fully Automated |
| Channel Count | 12 parallel channels |
| Extraction Format | Cartridge-based SPE |
| Flow Rate Control | 0.1–120 mL/min |
| Solvent Selection Capacity | Up to 8 solvents (standard configuration: 7) |
| Sample Throughput | 12 samples per run |
| Sample Load Volume | 1 mL to unlimited |
| Wetted Materials | Stainless steel (316), PTFE, borosilicate glass |
| Pressure Output Range | 0–30 psi (0–2.07 bar) |
| Input Max | 100 psi (6.9 bar) |
| Valve Type | Non-metallic 12-position rotary valve |
| Syringe Pump Volume | 10 mL per channel |
| Positioning Accuracy | ±0.1 mm |
| Liquid Handling Accuracy | ≥99% |
| Fraction Collection Volumes | Standard 15 mL (customizable) |
| Data Interface | USB |
| Operating System Compatibility | Windows XP/7/8 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Hanuo |
|---|---|
| Model | HN-2008 |
| Ultrasonic Power | 100–1500 W (continuously adjustable) |
| Ultrasonic Frequency | 20–25 kHz |
| Temperature Control Range | −20 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Reaction Volume Capacity | 10–500 mL |
| Probe Diameter Options | 6, 10, 15, 20, 25 mm |
| Magnetic Stirring Speed | 0–1200 rpm |
| Refrigeration System | Imported Tecumseh (USA) compressor, 650 W, 6 L cold bath capacity |
| Heating Power | 300 W |
| Sealed Reaction Vessel Configuration | Multi-port design with gas inlet, liquid addition port, vacuum outlet, and reflux condenser compatibility |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HN-650CT |
| Ultrasonic Power | 650 W |
| Ultrasonic Frequency | 20 kHz |
| Heating Power | Standard |
| Temperature Range | −5 to 100 °C |
| Chamber Capacity | 600 mL |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-650CT |
| Ultrasonic Power Range | 100–3000 W |
| Ultrasonic Frequency | 20 kHz |
| Maximum Heating Power | 2 kW |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume Capacity | 100–5000 mL |
| Brand | Heathrow Scientific |
|---|---|
| Origin | USA |
| Model | Gusto |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 500–12,500 rpm (in 100-rpm increments) |
| RCF Max | 9,800 × g |
| Capacity | 12 × 1.5 mL tubes (compatible with 0.2/0.5/1.5/2.0 mL microtubes) |
| Timer Range | 1 s – 30 min (1-s increment) |
| Dimensions | 203 × 171 × 114 mm |
| Power Input | 100–240 V AC, 50/60 Hz |
| Safety Features | Lid interlock, imbalance detection, automatic rotor stop |
| Noise Level | <55 dB(A) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing Refrigerated Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 18,038 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 650 × 814 × 973 mm |
| Weight | ~219 kg |
| Noise Level | 58 dB(A) |
| Power Supply | 230–240 V, 1~ |
| Power Consumption | 3,800 VA |
| EMC Compliance | EN/IEC 61326-1, Class B |
| Brand | Haiguang Instruments |
|---|---|
| Origin | Beijing, China |
| Model | HGE-300 |
| Extraction Type | Solid-Liquid Extraction |
| Sample Capacity | Up to 24 Positions |
| Solvent Handling | Automated Switching, Blending, and Proportional Mixing of Up to 4 Solvents |
| Sealing Material | TFM (Perfluoroalkoxy) Gaskets |
| Safety Features | Integrated Pneumatic Circuit Protection Against Solvent Corrosion and Backflow |
| Compliance Context | Designed for GLP-compliant laboratories |
| Brand | Hookoins |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 210 °C |
| Pressure Range | 0–20 MPa |
| Extraction Cell Volume | 5–120 mL |
| Extraction Time per Cycle | ≤30 min |
| Dimensions (W×D×H) | 690 × 535–715 mm |
| Sample Throughput | 6 parallel positions |
| Heating Uniformity | Full-wrap 6-channel furnace |
| Control Interface | High-resolution color touchscreen with graphical workflow display |
| Solvent Delivery | Quaternary solvent blending system (4 independent solvent lines) |
| Pump Specifications | 0–100 mL/min, max. 260 bar |
| Integrated Safety | Real-time pressure/temperature monitoring per channel, seal-cycle counter, solvent-level alarm, automatic pressure relief, N₂ purge and solvent flush |
| Online Conditioning | In-line water removal and matrix cleanup modules |
| Collection Vessel Compatibility | 60–250 mL bottles (customizable) |
| Power Requirement | 220 V AC, 50/60 Hz, 1800 W max |
| Operating Environment | 0–35 °C, ≤80% RH |
| N₂ Supply | 6–10 bar inlet pressure |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | G-L |
| Maximum Speed | 15,700 rpm |
| Rotor Capacity | 12 × 1.5/2.0 mL tubes |
| Relative Centrifugal Force (RCF) | 16,500 × g |
| Acceleration Time to Max Speed | 17 s |
| Deceleration Time from Max Speed | 18 s |
| Speed Accuracy | ±100 rpm |
| Speed Deviation | ±2.5% |
| Timer Range | Yes (LED display) |
| Unbalance Detection | Yes |
| Quick-Stop Function | Yes |
| Auto-Lid Opening | Yes |
| Safety Lid Interlock | Yes |
| Noise Level | 55 dB(A) |
| Dimensions (W × D × H) | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Operating Ambient Temperature | +5 to +40 °C |
| Max. Relative Humidity | 80% (non-condensing) |
| Protection Class | IP20 (DIN EN 60529) |
| Power Supply | 220–230 V, 50/60 Hz |
| Input Power | 92 W (operational), 3 W (standby) |
| USB Interface | Yes |
| Display Unit Conversion | rpm ↔ RCF |
| Motor Type | Brushless DC |
| Rotor Material | Anodized aluminum alloy |
| Compliance | CE, IEC 61010-1, IEC 61010-2-020 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Benchtop Centrifuge |
| Speed Range | 800 – 15,700 rpm |
| Max RCF | 16,500 × g |
| Max Capacity | 12 × 1.5/2.0 mL tubes |
| Rotor Compatibility | Fixed-angle rotor (autoclavable at 121 °C, 2 bar) |
| Dimensions (W×D×H) | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Power Supply | 220–230 V / 115 V / 100 V, 50/60 Hz |
| Input Power | 92 W (operational), 18 W (standby) |
| Protection Class | IP20 (DIN EN 60529) |
| Operating Environment | +5 to +40 °C, ≤80% RH |
| Safety Features | Lid interlock, imbalance detection, rapid brake, automatic lid opening |
| Display | LED, 7-segment |
| Control Interface | Membrane keypad with RPM/RCF toggle |
| USB Port | Yes |
| Timer | Yes |
| Rotor Auto-Recognition | No |
| Balance Monitoring | Yes |