| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Avanti JXN-30 |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Separation Class | Cellular & Bacterial |
| Maximum Capacity | 4.0 L |
| Maximum Speed | 30,000 rpm |
| Maximum RCF | 110,510 × g |
| Dimensions (W × D × H) | 86.5 cm × 71.0 cm × 87.6 cm |
| Temperature Range | −20 °C to +40 °C |
| Temperature Uniformity (after equilibrium) | ±2 °C |
| Acceleration Profiles | 10 selectable curves |
| Deceleration Profiles | 11 selectable curves |
| Speed Accuracy | ±10 rpm or ±0.15% (whichever is greater) |
| Run Time Range | 1 min to 99 h 59 min (or continuous mode) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti JXN-30 |
| Instrument Type | Floor-Model Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Max RCF | 110,500 × g |
| Max Capacity | 4 L (4 × 1 L rotors) |
| Cooling Range | -10 °C to +40 °C |
| Dimensions (W×D×H) | 86 × 71 × 86 cm |
| Rotor Compatibility | Fixed-angle, swinging-bucket, JLA series ultra-lightweight rotors |
| Drive System | Variable Reluctance Motor |
| Acceleration/Deceleration Rates | 12/13 steps |
| Timer Range | 0:01–99:59 h, Hold mode, ω²t integration |
| Data Storage | 1,000 user-defined protocols, 50 user accounts, real-time run curve logging |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11 audit trail requirements via optional software modules |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F0650 |
| Instrument Type | Benchtop Centrifuge |
| Maximum Capacity | 6 × 50 mL |
| Maximum Speed | 21,000 rpm (with Allegra 64R) |
| Maximum RCF | 41,400 × g (with Allegra 64R) |
| Rotor Type | Fixed-Angle |
| k-Factor | 795 |
| BioC Certification | Not Applicable |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | F1010 |
| Instrument Type | Benchtop Centrifuge Rotor |
| Rotor Type | Fixed-Angle |
| Max Capacity | 10 × 10 mL |
| Max Speed | 26,000 rpm |
| Max RCF | 57,440 × g |
| k-Factor | 500 |
| Compatible Systems | Allegra 64R and Allegra X-30 Series Centrifuges |
| BioC Certification | Not Applicable |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | J6 |
| Maximum RCF | 6,835 × g |
| Maximum Speed | 6,000 rpm |
| Microprocessor Control | Yes |
| Acceleration/Deceleration Rates | 9/9 |
| Programmable Methods | 10 |
| Brushless Drive Motor | Yes |
| Capacity | 6 L (e.g., 12 blood bags, 18 microplates, or 336 RIA tubes) |
| Rotor Compatibility | JS-4.2A, JS-4.2SMA ARIES (auto-balancing within ±50 g), JE-6B & JE-5.0 elutriation rotors |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Microfuge 16 / Microfuge 18 / Microfuge 22R |
| Refrigeration | Yes (Microfuge 22R only) |
| Max RCF | 16,160 × g (Microfuge 16), 18,000 × g (Microfuge 18), 21,920 × g (Microfuge 22R) |
| Max Speed | 14,000 rpm (Microfuge 16), 14,800 rpm (Microfuge 18 & 22R) |
| Capacity | 3 × 1.5 mL (Microfuge 16), 24 × 1.5 mL (Microfuge 18 & 22R) |
| Temperature Range | –20 °C to +40 °C (Microfuge 22R) |
| Noise Level | ≤58 dBA |
| Acceleration/Deceleration Profiles | 10 selectable rates |
| Run Time | Up to 9 h 59 min continuous or short-spin mode |
| Balance Correction Range (ARIES) | ±50 g |
| Rotor Compatibility | 20 interchangeable rotors |
| Motor Type | Brushless DC drive |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Microfuge 16 |
| Centrifuge Type | Benchtop Centrifuge |
| Speed Range | 0–14,800 rpm |
| Max RCF | 16,163 × g |
| Max Capacity | 24 × 2.2 mL |
| Dimensions (W×D×H) | 266 × 266 × 176 mm |
| Rotor Configuration | Fixed-angle rotor with dual-row asymmetric bore geometry |
| Tube Compatibility | 0.2–2.2 mL microtubes |
| Acceleration Time | 13 s (0–14,800 rpm) |
| Deceleration Time | 11 s (14,800 rpm → 0) |
| Motor Type | Brushless induction motor |
| Rotor Sterilization | Autoclavable (121 °C, 20 min) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm) |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 20,627 × g |
| Maximum Capacity | 36 × 2.0 mL |
| Dimensions (W × D × H) | 31.0 × 42.0 × 27.0 cm |
| Temperature Range | 5–40 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 s to 99 min 59 s (or continuous) |
| Display | Simultaneous rpm and RCF readout |
| Rotor Compatibility | FA361.5 fixed-angle rotor (standard), plus three additional optional rotors |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Microfuge 20 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Maximum RCF | 20,627 × g |
| Maximum Capacity | 36 × 1.5/2.0 mL tubes |
| Temperature Control | Non-refrigerated (Microfuge 20) |
| Rotor Options | 4 interchangeable fixed-angle rotors including biocontainment-certified rotor |
| Dimensions (W×D×H) | 31 × 42 × 27 cm |
| Compliance | Meets IEC 61010-1 safety standards |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Benchtop Refrigerated Centrifuge |
| Model | Microfuge 20R |
| Centrifuge Category | High-Speed Refrigerated Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 20,627 × g |
| Max Capacity | 36 × 2.0 mL |
| Dimensions (W × D × H) | 31 × 66 × 29.1 cm |
| Rotor Type | Fixed-Angle (e.g., FA361.5) |
| Application Scope | Cellular & bacterial pelleting, nucleic acid/protein isolation, subcellular fractionation, phase separation, receptor binding assays, and particulate sedimentation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Microfuge® 16 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Microcentrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Cellular & Bacterial Pelletation |
| Maximum Capacity | 24 × 2.0 mL |
| Maximum Speed | 14,800 rpm |
| Maximum RCF | 16,163 × g |
| Dimensions (W × D × H) | 22.6 cm × 26.6 cm × 17.6 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model Series | Optima L-100XP, L-80XP, L-100K, L-90K |
| Max RCF | 802,400 × g (L-100XP/L-100K), 602,000 × g (L-80XP), 694,000 × g (L-90K) |
| Max Speed | 100,000 rpm (L-100XP/L-100K), 80,000 rpm (L-80XP), 90,000 rpm (L-90K) |
| Temperature Control Accuracy | ±0.3 °C (L-100XP), ±0.5 °C (L-80XP/L-100K/L-90K) |
| Software | eXPert Centrifuge Software (full version) |
| Vacuum System | Oil-free, dehydration-based |
| Motor Drive | Hermetically sealed vacuum drive |
| Safety | Dynamic rotor inertia monitoring, automatic rotor recognition, HEPA-filtered exhaust |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Optima MAX-TL |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Ultracentrifuge (>30,000 rpm) |
| Function | General-purpose ultracentrifugation |
| Configuration | Horizontal rotor compatible |
| Separation Level | Cellular and bacterial subfractionation |
| Maximum Capacity | 40.8 mL |
| Maximum Speed | 120,000 rpm |
| Maximum RCF | 657,000 × g |
| Dimensions (W × D × H) | 73.9 × 61.7 × 39.4 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Desktop Ultracentrifuge |
| Speed Range | Up to 120,000 rpm |
| Maximum RCF | 657,400 × g |
| Maximum Capacity | 8 × 5.1 mL |
| Refrigeration | Yes (Cryogenic Cooling) |
| Rotor Compatibility | Full backward compatibility with Optima TL-series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Safety Certification | BioSafe-compliant design |
| Display | Full-color LCD touchscreen with multilingual UI (including Chinese and English) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-TL |
| Instrument Type | Tabletop Centrifuge |
| Speed Range | Up to 120,000 rpm |
| Max RCF | 657,000 × g |
| Max Capacity | 6 × 85 mL |
| Dimensions (W×D×H) | 61.7 × 73.9 × 34.5 cm |
| Rotors Compatibility | Full interchangeability with Optima TL series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Safety Features | Integrated HEPA filtration, biosafety-certified rotors and tubes |
| Display | Touchscreen LCD with bilingual (English/Chinese) UI support |
| Application Scope | Subcellular fractionation, virus purification, lipoprotein isolation, macromolecular sedimentation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Benchtop Ultracentrifuge |
| Speed Range | Up to 150,000 rpm |
| Max RCF | 1,019,400 × g |
| Max Capacity | 194.4 mL |
| Sample Volume Range | 0.175–194.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Compliance | Designed for GLP/GMP environments with electronic audit trail support |
| Rotor Types | Fixed-angle, swinging-bucket, vertical, near-vertical |
| Safety | Integrated biosafety features including optional HEPA aerosol containment |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-XP |
| Centrifuge Type | Benchtop Ultracentrifuge |
| Maximum Speed | 150,000 rpm |
| Maximum RCF | 1,019,000 × g |
| Maximum Capacity | 6 × 32.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Sample Volume Range | 0.175–194 mL |
| Operating Temperature Range | 0–40 °C |
| Noise Level | <55 dBA (typical at 150,000 rpm) |
| Interface Language | English / Chinese selectable |
| Security Compliance | User authentication, electronic audit trail, FDA 21 CFR Part 11–ready software architecture |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 rpm |
| Max RCF | 802,400 / 694,000 × g |
| Max Capacity | 1.5 L |
| Temperature Range | 0–40 °C (1 °C increment) |
| Temp Accuracy | ±0.5 °C |
| Acceleration Profiles | 10 selectable |
| Deceleration Profiles | 11 selectable (including coast-down) |
| Speed Control Resolution | ±2.00 rpm (≥1,000 rpm) |
| Runtime | up to 999 h 59 min |
| Noise Level | <51 dBA |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, ISO 13485 certified, GLP/GMP-compatible design |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Drive System | Refrigerated Brushless Induction Motor |
| Temperature Control | 0–40 °C (±0.5 °C) |
| Power Supply | 180–264 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Acoustic Noise Level | <51 dBA |
| Standby Power Consumption | <60 W |
| Compliance | ISO 13485, IEC 61010-1, FDA 21 CFR Part 11 (software-enabled audit trail), GLP/GMP-ready configuration options |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Optima XPN |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Class | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Primary Function | Analytical & Preparative Ultracentrifugation |
| Typical Configuration | Fixed-angle Rotor System |
| Separation Target | Subcellular Organelles, Viruses, Macromolecular Complexes |
| Maximum Capacity | 1.5 L |
| Max Speed Options | 100,000 / 90,000 / 80,000 rpm |
| Max RCF | 802,000 × g / 694,000 × g / 548,300 × g |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 / 80,000 rpm |
| Maximum RCF | 802,000 / 694,000 / 548,300 × g |
| Maximum Capacity | 1.5 L |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical, near-vertical, and zonal rotors |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Safety Compliance | Meets IEC 61010-1, UL 61010-1, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Cooling | Refrigerated (2–30 °C) |
| Display | 15-inch capacitive touchscreen |
| Voltage Range | 180–264 VAC (auto-sensing) |
| Power Consumption (standby) | <60 W |
| Noise Level | <51 dBA |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP traceability features, ISO 13485-aligned design |
| Software | eXPert Centrifuge Software v5.x |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | ProteomeLab™ XL-A/XL-I |
| Instrument Type | Floor-standing Analytical Ultracentrifuge |
| Speed Range | Up to 70,000 rpm |
| Maximum RCF | 601,000 × g |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Detection Systems | UV-Vis (XL-A: 190–800 nm) or Interference Optics (XL-I) |
| Sample Capacity | Up to 21 cells simultaneously |
| Vacuum System | High-efficiency dehydration-type |
| Power Consumption | 3.4 kW/h |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Safety Features | Dynamic rotor inertia monitoring, hermetic vacuum drive, HEPA-filtered exhaust |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr CUS 2 |
| Pricing | Available Upon Request |
| Material | Borosilicate Glass (Compliant with ISO 9377-2) |
| Configuration | Dual-Column Parallel Setup |
| Weight | ~3 kg |
| Dimensions (W×D×H) | ~23 × 27 × 50 cm |
| Included Components | Support Stand, Two 100 mL Graduated Collection Flasks, Two Purification Columns (Part No. 2804800203), Two Dropping Funnels, Two Kuderna-Danish Concentration Vessels |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ET2 |
| Price | Upon Request |
| Dimensions (W×H×L) | 14.0 × 10.0 × 27.0 cm (unit only) |
| Weight | ~17 kg |
| Voltage | 220 V / 50 Hz |
| Max. Power Output | 2200 W |
| Load Type | Resistive (Ohmic), 4-pole threaded connector |
| Sensor | PT100, 3-wire configuration, via 3-pole screw terminal |
| Control Principle | PID with anti-drift compensation |
| Temp. Range | 20–450 °C |
| Temp. Accuracy | ±1 K |
| Time Range | 1–999 min (±1 min), continuous heating mode enabled |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr EX1000 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KEX Compact Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Rating | 450 W |
| Weight | ~7.5 kg |
| Dimensions (W×D×H) | ~23 × 33 × 71.5 cm (KEX 30) / ~23 × 33 × 80 cm (KEX 100) |
| Extraction Vessel Capacity | 30–500 mL |
| Sample Throughput | 1 sample per unit (compact configuration) |
| Condenser Interface | Standard threaded joint (compatible with Weibull/Stoldt acid hydrolysis units) |
| Drain Valve | Integrated piston valve for post-extraction solvent transfer |
| Cooling Requirement | Compatible with UK 12/400 recirculating chiller (380 W) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr KSMA |
| Pricing | Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Consumption | 450 W |
| Weight | approx. 6 kg |
| Dimensions (W × D × H) | approx. 230 × 330 × 800 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr R-Series Multi-Sample Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Configuration Options | 4-position & 6-position variants |
| Solvent Reservoir Capacity | 100 mL, 250 mL, or 300 mL per extraction chamber |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Power Consumption | 1140 W (4-position), 2160 W (6-position) |
| Current Rating | 8 A / 16 A (230 V), 10 A / 20 A (115 V) |
| Net Weight | ~15.1 kg (4-position), ~19.8 kg (6-position) |
| Dimensions (W×D×H) | ~530 × 320 × 740 mm (4-position), ~760 × 320 × 740 mm (6-position) |
| Condenser Cooling | Dual-path分流 water jacket with independent flow control per channel |
| Heating Control | Individual PID-regulated heating blocks per sample position |
| Safety Features | Overtemperature cutoff, solvent vapor containment design, drip-resistant condenser interface |
| Compliance | Designed in accordance with DIN EN ISO 14555 and AOAC Official Method 991.36 for fat determination |
| Brand | Beifen Sanpu |
|---|---|
| Model | SXT-6 |
| Channels | 6 |
| Extraction Flask Volume | 250 mL per channel |
| Sample Capacity | 0–5 g per channel |
| Temperature Control Range | Ambient +5 °C to 100 °C |
| Heating Power | 800 W |
| Power Supply | 220 V ±10 V, 50 Hz |
| Dimensions (W×D×H) | 725 × 230 × 740 mm |
| Weight | 25 kg |
| Compliance | GB 5512–1985 |