Separation/Extraction Equipment
Filter
Showing 241–270 of 366 results
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Miniature Low-Speed Benchtop Centrifuge |
| Model | IKA mini G |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 2000 × g |
| Maximum Capacity | 8 × 2.0 mL |
| Timer Range | 1–99 min (digital LED display) |
| Dimensions (W × D × H) | 155 × 175 × 105 mm |
| Weight | 1.4 kg |
| Power Supply | 24 V DC |
| Motor Input/Output Power | 12 W / 8 W |
| Safety Rating | DIN EN 60529 IP30 |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity Limit | ≤80% |
| Rotor Exchange | Tool-Free |
| Quick-Stop Function | Yes |
| Lid Interlock | Active (operation only with lid closed) |
| Noise Level | <45 dB(A) |
| Rotor Type | Fixed-angle, universal for 0.2–2.0 mL tubes |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | IKA mini G |
| Maximum Rotor Speed | 6000 rpm |
| Relative Centrifugal Force (RCF) | 2000 × g |
| Capacity | 8 × 2.0 mL tubes |
| Max. Kinetic Energy | 20 N·m |
| Motor Input Power | 12 W |
| Motor Output Power | 8 W |
| Speed Accuracy | ±0.05% of set speed |
| Timer Range | 1–99 min (LED display) |
| Continuous Operation | Yes |
| Quick-Stop Function | Yes |
| Automatic Rotor Lock Release on Lid Opening | Yes |
| Safety Lid Lock | Yes |
| Noise Level | 48 dB(A) |
| Dimensions (W×D×H) | 155 × 105 × 175 mm |
| Weight | 1.4 kg |
| Operating Ambient Temperature | 5–40 °C |
| Max. Relative Humidity | 80% RH (non-condensing) |
| Ingress Protection | IP 30 per DIN EN 60529 |
| Voltage Supply | 100–240 V AC, 50/60 Hz |
| DC Internal Supply | 24 V = |
| Current Draw | 500 mA |
| Rotor Compatibility | Fixed-angle rotor for 2.0 mL microtubes only |
| Density Limit for Samples | ≤1.2 kg/dm³ |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EasySPE-E8 |
| Automation Level | Semi-Automatic |
| Channel Count | 8-Channel Parallel |
| Extraction Format | Cartridge-Based SPE |
| Sample Capacity | 8 samples simultaneously |
| Sample Volume Range | 0.1 mL – 10 L |
| Solvent-Wetted Materials | PTFE (Teflon®)-Lined Tubing and Fluid Path |
| Cartridge Compatibility | 1 mL, 3 mL, 6 mL, and 12 mL SPE cartridges |
| Liquid Handling Accuracy | ±2% |
| Dimension (W×D×H) | 400 × 392 × 399 mm |
| Flow Control | Individually calibrated precision peristaltic pumps with real-time pressure stabilization |
| Optional Configurations | Large-volume sampling module |
| Brand | Jingrongyuan |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JRY-L10 |
| Extraction Time Range | 0–9999 min |
| Oscillation Mode | Vertical |
| Simultaneous Extraction Capacity | 10 separatory funnels |
| Oscillation Frequency | 0–350 rpm (infinitely adjustable) |
| Noise Level | <60 dB(A) |
| Oscillation Amplitude | 50 mm |
| Rated Voltage | 220 V, 50 Hz |
| Motor Power | 180 W |
| Net Weight | <30 kg |
| Construction Material | Cold-rolled steel with anti-corrosive epoxy powder coating |
| Compatible Funnel Sizes | 125 mL, 250 mL, 500 mL, 1000 mL |
| Brand | Jintaishi |
|---|---|
| Origin | Hunan, China |
| Model | DL7MS |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 300–7000 rpm |
| Max RCF | 11942 × g |
| Max Capacity | 6 × 2400 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±10 rpm |
| Acceleration/Deceleration | 9-step programmable |
| Noise Level | ≤65 dB(A) at 1 m |
| Power Supply | AC 220 V ±10 %, 50 Hz, 32 A |
| Dimensions (W×D×H) | 870 × 950 × 1000 mm |
| Weight | 580 kg |
| Refrigerant | R404A |
| Drive Motor | Inverter-Controlled Asynchronous Motor |
| Safety Features | Door Interlock, Overspeed Detection, Imbalance Detection, Overtemperature Protection |
| Data Storage | ≥3 months of operational logs, fault records, and user activity with export capability |
| Display | 10-inch full-color capacitive touchscreen |
| Compliance | Designed for GLP-compliant workflows |
| Brand | JRY |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JRY-SS |
| Extraction Chamber Capacity | 6 positions |
| Receiver Flask Volume | 500 mL per position |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Channels | 6 |
| Brand | JTONE |
|---|---|
| Origin | Hunan, China |
| Model | JT-SXT-02N / JT-SXT-04N / JT-SXT-06N |
| Extraction Chamber Volume | Not specified |
| Receiver Flask Volume | 500 mL |
| Temperature Range | Ambient +5 °C to 280 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Number of Parallel Extraction Channels | 2 / 4 / 6 |
| Heating Power | 300 W / 500 W / 800 W |
| Sample Capacity per Thimble | 0.5–20 g |
| Extractor Flask Volume | 250 mL (150 mL optional) |
| Power Supply | 220 V ±10 V, 50 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Aseeker-100 |
| Instrument Category | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 11 mL / 22 mL / 33 mL |
| Collection Vial Capacities | 40 mL / 60 mL |
| Solvent Flow Rate | 0.1–50 mL/min |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Gas Supply Requirement | Nitrogen, 0.4–1 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max. Power Consumption | 600 W |
| Dimensions (W×D×H) | 450 mm × 500 mm × 530 mm |
| Weight | 30 kg |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection with automatic shutdown, liquid-level sensing with overflow prevention, integrated post-extraction filtration |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aseeker-200 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 34 mL / 66 mL / 100 mL |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Pump Flow Rate | 0.1–50 mL/min |
| Collection Vial Capacities | 60 mL / 250 mL |
| Gas Supply Requirement | Nitrogen at 0.9–1.2 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.2 kW |
| Dimensions (W×D×H) | 508 mm × 485 mm × 745 mm |
| Weight | 40 kg |
| Wetted Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection, liquid-level sensing, pressure-deficiency alarm, automatic filtration post-extraction, dual-needle purge system to prevent splashing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Aseeker-500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 10 MPa (±0.5 MPa) |
| Extraction Cell Volume | Standard 34 mL (optional: 1, 5, 10, 22, 66, 100 mL) |
| Extraction Time per Sample | 20 min |
| Instrument Dimensions | 800 mm × 738 mm × 685 mm |
| Sample Capacity | 24 extraction cells |
| Collection Vials | Standard 19 × 250 mL or up to 28 × 60 mL + 5 × 250 mL with adapter |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Consumption | ≤1.2 kW |
| Input Voltage | 100–240 VAC ±10 %, 50–60 Hz |
| Solvent Mixing Capability | Up to 4 solvents |
| Cleaning Stations | 2 |
| Weight | 70 kg |
| Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Electronic over-pressure/over-temperature protection, leak detection with automatic shutdown and sequence bypass, external air supply pressure monitoring, infrared liquid-level sensing at collection vials |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GOODSPE-1200 |
| Automation Level | Fully Automatic |
| Channel Count | 1 |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min |
| Solvent Selection | 5 Independent Solvent Channels |
| Sample Capacity | Up to 288 Samples per Unattended Run |
| Sample Loading Volume | 20 mL – 20 L |
| Wetted Materials | PTFE, Borosilicate Glass |
| Valve Type | Non-Metallic 12-Port Rotary Valve |
| Pressure Output | 0–30 psi (0–1.4 bar) |
| Air Injection | Integrated 10 mL Air Syringe |
| Liquid Injection | Integrated 10 mL Liquid Syringe |
| Positioning Accuracy | 0.1 mm |
| Dispensing Accuracy | ≥99% |
| Data Interface | USB |
| Operating Voltage | 100–240 V AC, 50/60 Hz |
| Compliance | EPA Method-Compliant for Aqueous Matrix Analysis (e.g., EPA 508, 525.3, 8270) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GOODSPE-2000 |
| Price Range | USD 14,000–35,000 (FOB Shanghai) |
| Automation Level | Fully Automated |
| Channel Configuration | Single-Channel (Optional Dual-Channel) |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min |
| Solvent Selection Capacity | Up to 12 Solvents via Non-Metallic 12-Port Valve |
| Sample Throughput | 40 Samples per Batch |
| Sample Loading Volume | 1–50 mL |
| Wetted Materials | Borosilicate Glass, PTFE |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GOODSPE-3000 |
| Automation Level | Fully Automated |
| Number of Channels | 4 Parallel Channels |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min per channel |
| Solvent Selection | Up to 5 Pre-Loaded Solvents (Expandable to 10 via Custom 12-Position Non-Metallic Rotary Valve) |
| Sample Capacity | Up to 144 Sequential Samples |
| Sample Loading Volume | 1–50 mL |
| Wetted Materials | PTFE, Borosilicate Glass |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GOODSPE-3000B |
| Automation Level | Fully Automated |
| Channel Configuration | Modular — configurable as 1-, 2-, or 4-channel |
| Extraction Format | Cartridge-based SPE |
| Flow Rate Control | 0–30 mL/min per channel |
| Solvent Reservoirs | 8 independent solvent ports |
| Maximum Sample Capacity | 144 samples (using 1 mL cartridges) |
| Sample Loading Volume | 1–50 mL per run |
| Wetted Materials | PTFE and borosilicate glass |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-6000 |
| Automation Level | Fully Automatic |
| Channel Count | 6 parallel channels |
| Extraction Mode | Column-based and disk-based SPE |
| Flow Rate Control | 0.1–120 mL/min |
| Solvent Selection | Up to 5 independently programmable solvents |
| Sample Capacity | 6 samples simultaneously |
| Sample Load Volume | 20 mL – 20 L |
| Elution Pump | Dual syringe pump (10 mL liquid + 10 mL air) |
| Contact Materials | PTFE and borosilicate glass |
| Pressure Source | Regulated air supply (0–30 psi / 0–1.4 bar output |
| Valve Type | Non-metallic 12-position rotary valve |
| Waste Separation | Dedicated aqueous and organic waste lines |
| Compliance | EPA Method-compliant for water analysis (e.g., EPA 508, 525.3, 537, 8270) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-80 |
| Automation Level | Fully Automatic |
| Number of Channels | 8 |
| Extraction Mode | Column-Based SPE |
| Flow Rate Control Range | 0.01–15 mL/min |
| Solvent Selection | Up to 4 independent solvent lines |
| Sample Capacity | Simultaneous processing of up to 8 samples |
| Sample Loading Volume | 1–30 mL per channel |
| Wetted Materials | Stainless steel (316), PTFE, borosilicate glass, PEEK |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GOODSPE-8600 |
| Automation Level | Fully Automated |
| Number of Channels | 6 (configurable from 2 to 10) |
| SPE Format Compatibility | Cartridge & Disk (Column-Membrane Universal) |
| Flow Rate Range | 0.1–100 mL/min per channel |
| Solvent Selection | 8 independent solvent channels with multi-position valve switching |
| Sample Capacity | Up to 72 samples per batch |
| Sample Loading Volume | 1–80 mL (standard) |
| Elution Fraction Volumes | 20 mL or 80 mL (customizable) |
| Wetting/Soak Function | Yes |
| Sequential Column Stacking (Tandem SPE) | Yes |
| Solvent Contact Materials | PTFE (Teflon®), Borosilicate Glass |
| Waste Management | 3 independent waste lines (organic, aqueous, acidic) |
| Positioning Accuracy | ±0.1 mm |
| Liquid Handling Accuracy | ≥99% |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Software Interface | Windows-based GUI with real-time status monitoring, method error detection, audit-trail-enabled logging, and Wi-Fi connectivity |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SpeedMembrand-10 |
| Automation Level | Fully Automatic |
| Channel Configuration | Multi-channel (1/4/6/8 selectable) |
| Extraction Method | Membrane-based Solid Phase Extraction (SPE) |
| Flow Rate Range | 0–200 mL/min |
| Sample Volume Capacity | >2 L |
| Available Membrane Diameters | 47 mm, 50 mm, 90 mm |
| Compatibility | Designed for integration with KEZHE’s fully automated SPE systems |
| Material in Contact with Solvents | Chemically resistant polymer housing and fluidic path (e.g., PTFE, PEEK, or equivalent inert materials per standard SPE accessory design) |
| Structural Flexibility | Modular channel expansion/reduction capability |
| Dual-mode Support | Compatible with both cartridge-based and disk-type membrane SPE formats |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPSE Series |
| Instrument Type | Solid-Phase Extraction (SPE) / Pressurized Liquid Extraction (PLE) |
| Temperature Range | 0–50 °C |
| Pressure Range | Up to 10 MPa |
| Extraction Cell Volume | 10–100 mL (standard configuration supports 100 mL cells) |
| Flow Rate | Up to 100 mL/min |
| Dimensions (W × D × H) | 500 × 600 × 650 mm |
| Sample Capacity | 6 positions (modular |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PrepElite-GV |
| Automation Level | Fully Automated |
| Channel Configuration | Multi-channel |
| Extraction Mode | Column-based Solid Phase Extraction (SPE) |
| Flow Rate Control | Intelligent Precision Flow Control (0.1–100 mL/min) |
| Compatible Eluents | Multiple Organic Solvents (e.g., Methanol, Acetonitrile, Dichloromethane, Hexane) |
| Sample Capacity | Up to 96 Samples per Batch |
| Sample Loading Volume | 0.1–1000 mL (method-dependent) |
| Wetted Materials | Chemically Resistant Components (PTFE, 316L Stainless Steel) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PrepElite-SV |
| Automation Level | Fully Automatic |
| Channel Configuration | Multi-channel (up to 24-position SPE + dual-concentration modules) |
| Extraction Mode | Column-based Solid Phase Extraction (SPE) |
| Flow Rate Control | 0–120 mL/min (programmable, pressure-stabilized) |
| Solvent Selection | 8 independent solvent reservoirs with auto-switching capability |
| Sample Capacity | 124 positions (compatible with 12×10 rack + optional expansion) |
| Sample Loading Volume | 1–6 mL per vial |
| Wetted Materials | Borosilicate glass, PTFE, and chemically inert stainless steel (316L) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | Sepaths UP |
| Automation Level | Fully Automated |
| Channel Count | Multi-Channel |
| Extraction Type | Membrane-Based SPE |
| Flow Rate Control | 0–120 mL/min |
| Solvent Selection | 8 Independent Solvent Lines |
| Sample Capacity | Up to 12 Samples Simultaneously |
| Sample Loading Volume | 1–20 mL |
| Wetted Materials | PTFE and Stainless Steel |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LX-105 |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (≤ 6,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Maximum Capacity | 4 × 250 mL |
| Maximum Speed | 5,500 rpm |
| Maximum RCF | 4,800 × g |
| Speed Accuracy | ±20 rpm |
| Timer Range | 1 s – 99 h 59 min 59 s (including continuous and short-spin modes) |
| Drive System | High-Torque Brushless DC Inverter Motor |
| Control Interface | 7-inch LCD Touchscreen |
| Rotor Recognition | Not Supported |
| Acceleration/Deceleration | Programmable Ramp Rates |
| Vibration Damping | Integrated Passive Damping System |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 0.45 kW |
| Net Weight | 40.5 kg |
| Dimensions (L×W×H) | 450 × 565 × 365 mm |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LX-116 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 22,500 × g |
| Speed Accuracy | ±20 rpm |
| Timer Range | 1 s – 99 h 59 min 59 s (including continuous and short-spin modes) |
| Drive System | High-Torque Brushless DC Inverter Motor |
| Control System | Microprocessor-Based PWM Speed Control |
| Display | 7-inch Wide-View IPS LCD Touchscreen |
| Door Safety | Mechanical Interlock Lock |
| Vibration Damping | Specialized Passive Damping System |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 0.38 kW |
| Net Weight | 27.5 kg |
| Dimensions (L×W×H) | 360 × 460 × 335 mm |
| Brand | LuoXiangYi / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DDL-5M |
| Centrifuge Type | Benchtop Refrigerated Centrifuge |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 3780 × g |
| Maximum Capacity | 4 × 750 mL |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1–99 min |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 650 × 710 × 1100 mm |
| Net Weight | 170 kg |
| Refrigerant | R404a |
| Power Supply | AC 220 V, 50 Hz, 20 A |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | CSC-12S |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000 rpm |
| Max RCF | 21,250 × g |
| Sample Capacity | Standard 1″ and 1.5″ core plugs |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Ramp/Brake Profiles | 10 programmable curves |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 5 kW |
| Dimensions (L×W×H) | 710 mm × 840 mm × 1200 mm |
| Net Weight | 290 kg |
| Refrigerant | R404a (non-ozone-depleting) |
| Compliance | FDA-registered, GMP-compliant sealing (food-grade silicone monolithic gasket) |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6M |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Rotor Configuration | Horizontal (Swinging-Bucket) |
| Maximum Capacity | 6 × 1200 mL |
| Max Speed | 6,000 rpm |
| Max RCF | 6,680 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Control Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Time Setting | 1 min – 99 h 59 min |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 30 A |
| Dimensions (L×W×H) | 710 mm × 840 mm × 1200 mm |
| Net Weight | 320 kg |
| Refrigerant | R404a (non-ozone-depleting) |
| Motor | High-torque AC frequency-controlled motor |
| Safety Features | Electronic door lock, overspeed/overtemperature/unbalance detection, automatic fault alarm |
| Acceleration/Deceleration Profiles | 10 programmable ramp curves |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DL-8M |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 8,000 rpm |
| Max RCF | 11,260 × g |
| Max Capacity | 6 × 2,400 mL (14,400 mL total) |
| Temperature Range | –20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min |
| Refrigerant | R404a (non-ozone-depleting) |
| Noise Level | <70 dB(A) |
| Power Supply | AC 380 V, 50 Hz, 40 A |
| Dimensions (L×W×H) | 900 mm × 1000 mm × 1300 mm |
| Compliance | CE-marked per IEC 61010-1 |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | H14.5M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–14,500 rpm |
| Max RCF | 14,000 × g |
| Max Capacity | 12 × 1.5 mL or 12 × 2.2 mL (angular rotor) |
| Rotor Options | Aluminum angular rotor (sealed, autoclavable), 0.2 mL 8-tube strip rotor (4 × 8 positions, max 6,000 rpm / 2,140 × g) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 20 s – 99 min |
| Acceleration/Deceleration Time | ≤12 s (0 → max / max → 0) |
| Noise Level | <50 dB(A) |
| Dimensions (W×D×H) | 230 × 270 × 155 mm |
| Net Weight | 4.8 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 100 W |
| Temperature Rise | ≤10 °C after 30 min at maximum speed |
| Safety Certification | CE compliant |
| Rotor Material | Anodized aluminum with hermetic sealing |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TD-4K |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | Up to 4,000 rpm |
| Max RCF | 900 × g |
| Capacity | 6 × (1.5 mL / 0.5 mL / 0.2 mL) tubes |
| Noise Level | <48 dB(A) |
| Dimensions (L×W×H) | 189 mm × 161 mm × 122 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | ~1.0 kg |
| Rotor Type | Fixed-angle rotor |
| Target Applications | Cellular and bacterial pelleting, microsample clarification, PCR tube spinning, quick spin-down of column-based kits |