| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G10 |
| Measurement Principle | Photosynthetically Active Radiation (PAR) Interception Method |
| Instrument Type | Handheld Portable |
| Spectral Range | 400–700 nm |
| PAR Sensor Resolution | 1 μmol·m⁻²·s⁻¹ |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 0–100% RH |
| Power Supply | Dual 18650 Li-ion Batteries (3500 mAh each) |
| Charging Interface | USB-C, 5 V DC |
| Probe Length | 100 cm |
| Total Unit Length | 128 cm |
| Cable Length (External Sensor) | 2 m |
| Data Storage | 16 GB Internal + Standard SD Card Slot |
| Connectivity | Bluetooth 5.0, Optional Wi-Fi Module |
| Display | High-Brightness Touchscreen with Dual-Language UI (English/Chinese) |
| Auto-Measurement Interval | 1–60 min (up to 999 cycles) |
| GPS Integration | Built-in GNSS Receiver for Georeferenced LAI Mapping |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | IN-XM01 |
| Price | USD 3,500 (FOB) |
| Camera Resolution | 4000 × 3000 |
| Dual-Camera Setup | 50 MP + 12 MP |
| Measurement Accuracy (Spike Count) | ≤ ±3% |
| Live-Field Spike Detection Error | ±1% |
| Thousand-Kernel Weight (TKW) Accuracy | ±2% (calibrated to ≤0.5% residual error) |
| Adjustable Calibration Rod Range | 1000 mm × 1000 mm × (610–1120) mm & 1000 mm × 1000 mm × (1010–1920) mm |
| On-Device Storage | 256 GB |
| Operating System | Android-based UI with touch interface |
| Connectivity | Wi-Fi / 4G LTE |
| Data Export Format | Excel (.xlsx) with embedded GPS timestamps |
| Language Support | English & Chinese (toggleable) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Type | Standard Petri Dishes (90–110 mm diameter), 3M Petrifilm™, Compact Dry™, RIDA™ Filter Membranes, Fluorescent & Non-fluorescent Microbial Colonies |
| Imaging System | Sealed Light-Tight Dark Chamber with Stray-Light Elimination |
| Illumination | Dual-Independent Adjustable Top/Bottom LED Light Sources |
| UV Modules | 254 nm (sterilization & mutagenesis), 366 nm (fluorescence excitation for *E. coli*, GFP, etc.) |
| Camera | 16 MP Full-Color CMOS Sensor |
| Minimum Detectable Colony Size | 0.1 mm |
| Counting Accuracy | ≤ ±10% |
| Display | 15.6″ Touchscreen (1920 × 1080), Windows 10 64-bit OS, 256 GB Internal Storage |
| Software | Integrated Colony Recognition Engine with Multi-Mode Segmentation Algorithms |
| Compliance | Supports GLP-compliant audit trails, user-level access control, immutable PDF reporting, bilingual (EN/CN) UI |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | IN-LeafClear |
| Price | USD 67,000 (FOB) |
| Camera Resolution | 1608 × 1104 |
| Pixel Size | 9 µm × 9 µm |
| Frame Rate | 100 fps |
| Bit Depth | 12-bit |
| Interface | USB 3.0 |
| Lens Focal Length | 12 mm (adjustable) |
| Max Aperture | F/2.8 (adjustable) |
| HFOV | 62.11° |
| VFOV | 44.83° |
| Max Imaging Area | 50 cm × 35 cm |
| Excitation Wavelength | 450 nm (blue LED) |
| Actinic Light | 630 nm (red LED) |
| Far-Red Light | 730 nm |
| Actinic Irradiance Range | 90–1440 µmol/(m²·s) |
| OJIP Duration | 0.1–1.0 s |
| PAM Dark Adaptation | 0–3600 s |
| Saturation Pulse Intensity | 15–100% (450 nm) |
| Fluorescence Dynamic Range | 0–4095 (12-bit) |
| SNR | >100:1 |
| Repeatability (CV) | <3% |
| Linearity (R²) | >0.999 |
| Minimum Sampling Interval | 10 ms (OJIP), 100 ms (PAM) |
| Spatial Resolution | ~0.3 mm/pixel (at 50 cm × 35 cm FOV) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-ZT20 |
| Origin | Shandong, China |
| Manufacturer | COMECAUSE (OEM/ODM Producer) |
| Category | Plant Physiology & Ecology Instruments / Porometers |
| Measurement Principle | Open-path diffusion-based real-time gas exchange analysis |
| Temperature Range (Leaf Chamber) | –20–80 °C |
| Leaf Temperature Sensor | Pt100 platinum resistance thermometer, ±0.2 °C accuracy, 0.1 °C resolution |
| Air Humidity Sensor | Swiss-made digital hygrometer, 0–85% RH, ±1% RH accuracy, 0.1% RH resolution |
| PAR Sensor | Calibrated silicon photodiode with spectral correction filter (400–700 nm), 0–3000 μmol·m⁻²·s⁻¹, <1 μmol·m⁻²·s⁻¹ uncertainty |
| Flow Control | Precision micro-electronic mass flow controller, adjustable 0.2–1.0 L·min⁻¹, 0.0001 L·min⁻¹ resolution, ±0.005 L·min⁻¹ zero drift |
| Transpiration Rate (Tr) | mmol H₂O·m⁻²·s⁻¹ (±1–5% typical uncertainty) |
| Stomatal Conductance (Gs) | mol H₂O·m⁻²·s⁻¹ (±5–10% typical uncertainty) |
| Stomatal Resistance (Rs) | s·m⁻¹ |
| Display | 3.5″ TFT color LCD, 800×480 pixels |
| Data Storage | 16 GB internal flash memory (expandable to 32 GB) |
| Power | Rechargeable 8.4 V DC Li-ion battery, ≥20 h continuous operation (no external light source) |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (main unit only) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | IN-FT300 |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–300 W |
| Sample Volume Capacity | 0.1–300 mL (with interchangeable titanium alloy probes) |
| Pulse Control Resolution | 0.1 s (on/off/total time) |
| Temperature Monitoring Range | 0–99.9 °C (contact-type sensor) |
| Display | 10.1″ HD capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Transducer Housing | Aerospace-grade magnesium-aluminum alloy |
| Data Storage | 256 programmable protocols |
| Compliance | CE-marked design principles |
| Brand | COMECAUSE |
|---|---|
| Model | IN.GH2 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range (CO₂) | 0–3000 µmol/mol (ppm) |
| CO₂ Sensor | Dual-wavelength NDIR |
| Temperature Control | Integrated Peltier-based thermal stabilization |
| Pressure Compensation | Built-in barometric sensor (30–110 kPa) |
| PAR Sensor | Calibrated silicon photodiode with cosine-corrected optical filter |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288 (quad-core, 1.88 GHz) |
| Memory | 1 GB RAM / 16 GB ROM |
| Battery | 8000 mAh Li-ion (10–12 h field operation) |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.2, USB 2.0, USB-C charging |
| Data Export | CSV via USB flash drive (plug-and-play), wireless upload to cloud platform |
| Compliance | Designed for GLP-aligned field and lab use |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YMJ-A |
| Width Range | 0–155 mm |
| Length Range | 0–2000 mm |
| Area Unit | cm² |
| Resolution | 0.01 cm² |
| Measurement Accuracy | ±2% |
| Data Storage Capacity | 5000 sets |
| Power Supply | Built-in 3200 mAh Li-ion battery + removable 1400 mAh external battery |
| Display | LCD with microcontroller interface |
| Calibration | User-accessible internal calibration module |
| Interface | Type-C (data export only on YMJ-B/G variants) |
| Compliance | Designed for field-deployable plant phenotyping in accordance with ISO 11769 (Plant biology — Terminology for leaf morphometric parameters), ASTM E2918-22 (Standard Guide for Field Data Collection in Plant Science Studies) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G200 |
| Principle | Digital Image Analysis |
| Form Factor | Portable |
| Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–2000 µmol·m⁻²·s⁻¹ |
| Imaging Resolution | 2592 × 1944 |
| Field of View | 100° (Zenith: 0°–75° in 10 zones |
| Azimuth | 360° in 10 zones) |
| Display | 10-inch color touchscreen |
| Onboard Storage | 20 GB |
| Data Transmission | 4G LTE |
| Power Supply | 200 W solar panel + 130 Ah gel battery (AC 220 V optional) |
| Operating Temperature | −10 °C to +55 °C |
| Deployment Radius | Up to 30 m from host unit |
| Minimum Sampling Interval | 1 hour |
| Cloud Platform | Proprietary agricultural data center with role-based access and CSV export |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | IN-G30 |
| Principle | Hemispherical Image Analysis |
| Type | Portable |
| Spectral Range | 400–700 nm |
| Lens FOV | 180° (Fisheye) |
| Resolution | 2592 × 1944 |
| PAR Measurement Range | 0–3000 μmol·m⁻²·s⁻¹ |
| Operating Temperature | −10°C to 55°C |
| Relative Humidity | ≤85% RH |
| Weight | 500 g |
| Interface | USB |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Range | 0–4.99 MPa (0–49.9 bar) |
| Accuracy | ±0.01 MPa |
| Display | 4.3″ Color LCD Touchscreen |
| Pressure Chamber Volume | 4 L, Rated Pressure: 12 MPa |
| Data Storage | Up to 9,999 records |
| Power Supply | Rechargeable Battery (24 h @ max brightness) |
| Dimensions (Instrument Box) | 520 × 330 × 206 mm |
| Dimensions (Pressure Chamber Box) | 530 × 420 × 206 mm |
| Net Weight | ~12 kg per box |
| Units | MPa / bar selectable |
| Compliance | Designed for GLP-aligned field and lab use |