| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEEB140 |
| Hardness Scales | HL, HB, HRB, HRC, HV, HS |
| Display | Full Chinese LCD Menu Interface |
| Printer | Built-in High-Speed Thermal Printer |
| Environmental Rating | Vibration-Resistant, Shock-Resistant, EMI-Immune |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 16859, ASTM A956 (Leeb Method) |
| Data Traceability | On-device Printout with Timestamp & Sample ID Support |
| Power Supply | Rechargeable Li-ion Battery |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | TH520 |
| Testing Direction | Vertical |
| Maximum Test Height | 400 mm |
| Applicable Standards | ASTM E18, ISO 6508, JIS Z 2245 |
| Hardness Scales | HRA, HRB, HRC, HRD, HRF, HRG, HRH, HRR, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T |
| Load Application | Automatic motorized loading with dual-scale force system (major/minor loads) |
| Indenter Types | Diamond cone (120°, 0.2 mm tip radius) and hardened steel ball (1/16", 1/8", 1/4", 1/2") |
| Measurement Repeatability | ≤ ±0.5 HR under standardized conditions |
| Compliance | GLP-ready architecture with audit-trail-capable software interface |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U2 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ASTM A1038, ISO 17643, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 98 MHz |
| Resolution | 1 HV |
| Repeatability | ±1.5 HV (under controlled conditions) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥2,000 readings |
| Interface | USB-C, Bluetooth 5.0 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Leeb810A |
| Type | Shore A Hardness Tester |
| Display | Digital LCD |
| Application Scope | Rigid Plastics, Hard Rubbers, Coatings, and Polymer-Based Industrial Materials |
| Compliance | ASTM D2240, ISO 7619-1, ISO 868 |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBRV-187.5 |
| Type | Combined Brinell, Rockwell & Vickers Hardness Tester |
| Drive | Motorized Load Application |
| Compliance | ASTM E10, ASTM E18, ASTM E92, ISO 6506, ISO 6508, ISO 6507 |
| Application Scope | Ferrous & Non-ferrous Metals, Heat-Treated Surfaces, Thin Hardened Sheets, Cast Iron, Carbides, Annealed & Tempered Steels |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U3 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 17673, ASTM A1038, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 10 MHz |
| Resolution | 1 HV |
| Repeatability | ≤ ±1.5 HV (per ISO 17673) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥ 12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥ 2,000 readings with timestamp, location tag (optional GPS), and operator ID |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | U918 |
| Compliance | DIN 50159-1:2008, ASTM A1038-2005, JB/T 9377-2010, JJG 654-2013, GB/T 34205-2017 |
| Calibration Modes | 10-point factory calibration, single-point elastic modulus compensation, multi-point direct hardness calibration (HRC, HRB, HRA, HB, HV5) |
| Display | 3.5″ color LCD with real-time statistics (min/max/avg/count/timestamp) |
| Indentation Size | <20 µm diameter (requires >200× optical magnification for visualization) |
| Measurement Time | ≤2 s per test |
| Battery | 3.6 V / 3000 mAh Li-ion, up to 15 h operation |
| Data Storage | 50 test sets + 10 calibration profiles |
| Connectivity | Bluetooth printer support (optional), USB-C PC data export |
| Test Orientation | Omnidirectional (±5° tolerance from perpendicular) |
| Hardness Scales | HV, HRC, HRA, HRB, HB (directly calibrated, no conversion tables required) |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-150 |
| Type | Portable Shear-Pin Operated Brinell Hardness Tester |
| Force Application | Mechanical Screw-Driven & Hammer-Impact Dual Mode |
| Hardness Scale | HBW (Brinell Hardness Number, tungsten carbide ball indenter) |
| Indentation Measurement | Optical Readout via Integrated Eyepiece Microscope |
| Compliance | Designed per ISO 6506-1, ASTM E10, and JIS Z 2243 standards |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBS-3000 |
| Hardness Scale | HBW (Brinell, tungsten carbide ball indenter) |
| Test Force Range | 187.5 kgf to 3000 kgf (standard Brinell load range per ISO 6506-1) |
| Indenter | 10 mm hardened steel or tungsten carbide ball |
| Optical Measurement System | High-magnification eyepiece with calibrated scale or digital image capture (optional) |
| Display | Large LCD screen with real-time test parameter and result visualization |
| Data Output | RS-232 or USB interface for printer or PC connectivity |
| Compliance | Designed to meet ISO 6506-1, ASTM E10, and JIS Z 2243 requirements |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-750 |
| Applicable Standard | ASTM E110, GB/T 4285 |
| Test Force | 750 kgf (fixed) |
| Force Application Method | Manual lever-driven hydraulic system with pressure-relief control valve |
| Indentation Hold Equivalent | 10–15 s via 3–4 repeated pressure peaks to 750 kgf |
| Mounting Method | Permanent magnet base for ferromagnetic substrates |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | MHVSX-50 |
| Loading Method | Electromechanical Closed-Loop Force Control |
| Indentation Measurement | Dual-axis Encoder-equipped Eyepiece (D1/D2) |
| Display | 7-inch High-Sensitivity Touchscreen GUI |
| Optical System | High-Resolution Metallurgical Objective Lens with 10-Step Adjustable LED Illumination |
| Data Output | USB Export to Excel (.xlsx) |
| Hardness Conversion | Vickers (HV), Brinell (HB), Rockwell (HRB/HRC) |
| Compliance | ASTM E92, ISO 6507-1, JIS Z 2244 |
| Automation | Fully Automated Turret Positioning, Motorized Indenter/Objective Switching, Auto-Focus Optional |
| Software Interface | PC Communication via Optional RS-232/USB Protocol with Audit Trail Support |