- All
- Favorite
- Popular
- Most rated
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | A100ISM |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH / ORP, Conductivity, Dissolved Oxygen (DO), Residual Chlorine, Turbidity |
| DO Range | 0.00–20.00 mg/L |
| Turbidity Ranges | 0–20 NTU / 0–400 NTU / 0–4000 NTU (customizable) |
| Temperature Compensation | 0–100 °C (manual or automatic) |
| Output | Isolated 4–20 mA (max. load 500 Ω), independent for measured parameter or temperature |
| Alarm Outputs | 3 relay outputs (3 A / 250 V AC, SPST NO), configurable for high/low limits with adjustable hysteresis |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤7 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm (H × W) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | A20DO-AA1 |
| Instrument Type | Online |
| Measurement Principle | Electrochemical Probe — Clark-type Polarographic |
| Measurement Range | 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Resolution | 0.01 ppm |
| Stability | ≤0.02 ppm/24 h |
| Temperature Compensation | 0–100 °C (Manual / Automatic with PT1000 or NTC10K sensor) |
| Output Signals | Dual isolated 4–20 mA outputs (independently assignable to DO and temperature), max. load 500 Ω |
| Relay Outputs | Two programmable SPST relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm (H × W) |
| Display Language | English / Chinese (user-selectable) |
| Brand | APURE |
|---|---|
| Model | A200ISM |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH / ORP, Conductivity, Dissolved Oxygen (DO), Residual Chlorine, Turbidity |
| DO Range | 0.00–20.00 mg/L |
| Turbidity Ranges | 0–20 NTU / 0–400 NTU / 0–4000 NTU (customizable) |
| Temperature Compensation | 0–100 °C (manual or automatic) |
| Output | Isolated 4–20 mA (max. load 500 Ω), independently assignable to parameter or temperature |
| Relay Outputs | 3 configurable SPDT relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤7 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Dimensions | 144 × 144 × 115 mm (H × W × D) |
| Panel Cutout | 138 × 138 mm |
| Display Language | Chinese (default), switchable to English |
| Enclosure Rating | IP65 (front panel) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | A11PR-AA1 |
| Price | USD 70 (FOB Shanghai) |
| Measurement Range | pH: 0.00–14.00 |
| ORP | −2000 to +2000 mV |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.2 °C |
| Dimensions | 96 mm (H) × 96 mm (W) × 128 mm (D) |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A30CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–100 °C |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions (H×W×D) | 48 × 96 × 110 mm |
| Mounting Cutout | 42 × 90 mm |
| Output | Isolated 4–20 mA (configurable for conductivity, resistivity, or temperature) |
| Relay Output | 1 × SPDT, 3 A / 250 V AC, programmable high/low alarm with adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤15 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AYT-50S |
| Price | USD 420 (FOB Shanghai) |
| Accuracy Class | ±0.5% of reading |
| Measurable Flow Velocity | 0.1–15 m/s |
| Effective Measurement Range | 0.3–10 m/s (at ±0.5% accuracy) |
| Nominal Pipe Diameter | DN10–DN2000 |
| Nominal Pressure Rating | PN0.6–PN6.3 MPa |
| Fluid Temperature Limit | ≤160°C |
| Display | Low-Power LCD with Local Digital Readout |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | KS-600 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Free Chlorine, Turbidity, Temperature |
| Application Scope | Swimming Pools, Secondary Water Supply in Residential Communities, Municipal Water Distribution Networks, Water Treatment Plants, Cooling Water Systems |
| Connectivity | RS485/Modbus RTU, Optional 4G LTE or Ethernet for Cloud Data Upload |
| Compliance Framework | Designed to support GLP-aligned operational logging |
| Brand | Apure |
|---|---|
| Model | RP-3000 |
| Measurement Range | pH 0–14, ORP −1999 to +1999 mV |
| Resolution | 0.01 pH, 1 mV |
| Accuracy | ±0.01 pH, ±1 mV |
| Temperature Compensation | 0–100 °C (manual/automatic with PT1000 sensor) |
| Output | Dual isolated 4–20 mA (pH and ORP configurable) |
| Relay Outputs | 2 SPDT relays (configurable high/low alarm for pH or ORP) |
| Display | 800×480 IPS color LCD |
| Enclosure Rating | IP65 |
| Dimensions | 144×144×115 mm (H×W×D) |
| Power Supply | AC 100–240 V, ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Calibration | Manual 2- or 3-point using standard buffers (pH 4.00, 6.86, 7.00, 9.18, 10.00) |
| Stability | ≤0.02 pH/24 h, ≤3 mV/24 h |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10PR-A |
| Measurement Range | pH 0.00–14.00 |
| ORP | −1999 to +1999 mV |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.01 pH / ±1 mV |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Environmental Operating Range | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA outputs (configurable for pH/ORP and temperature) |
| Relay Outputs | Two programmable SPST relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Stability | ≤0.02 pH/24 h |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | Apure |
|---|---|
| Model | KS-500 |
| Origin | Shanghai, China |
| Manufacturer | Apure (Shanghai) Co., Ltd. |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH (0.01–14.00), Conductivity (0.01–30,000 µS/cm), Turbidity (0.001–4000 NTU), Dissolved Oxygen (0.01–20.0 mg/L), Free Chlorine (0.05–20 mg/L), Temperature (0.1–100.0 °C) |
| Output Interfaces | 2× RS485 (MODBUS RTU), 1× RS232 or DTU option |
| Sample Flow Rate | 400–600 mL/min |
| Inlet/Outlet | G1/2 BSP |
| Dimensions | 1470 × 500 × 400 mm |
| Weight | ~45 kg |
| Operating Sample Temperature | 5–40 °C |
| Power Supply | 100–240 VAC |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | A20CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | −30 °C to +150 °C (manual or automatic with PT1000/NTC10K sensor) |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions | 144 mm (H) × 144 mm (W) × 115 mm (D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Environmental Operating Conditions | 0–60 °C, ≤85% RH (non-condensing) |
| Mounting Cutout | 138 mm × 138 mm |
| Analog Outputs | Two isolated 4–20 mA outputs (conductivity/resistivity and temperature, max. load 500 Ω) |
| Relay Outputs | Two SPDT relays (3 A / 250 V AC, NO contact), configurable for high/low alarm with adjustable hysteresis |
| Display Language | Switchable between Chinese and English |
| Password Protection | User-accessible configuration lock |
| Menu Navigation | Context-sensitive on-screen prompts |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | S-730 |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–30 g/L |
| Display | LCD |
| Units | g/L, mg/L, NTU |
| Resolution | 0.001 g/L or 1 mg/L |
| Accuracy | ±1.0% FS |
| Repeatability | ±1.0% FS |
| Ambient Temperature | −20 to +60 °C |
| Relative Humidity | (65 ± 20)% |
| Analog Output | 4–20 mA (750 Ω load) |
| Alarm Output | Dual SPDT relays |
| Digital Output | RS485 (optional) |
| Power Supply | AC 220 V ±10% or DC 24 V |
| Housing Material | SS316 |
| Process Temp. Range | 0–60 °C |
| Max. Pressure Rating | 1.0 MPa |
| Process Connection | 3/4″ NPT |
| IP Rating | IP68 |
| Installation Options | Immersion bracket or inline pipe insertion |
| Standard Cable | Shielded, 10 m |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | A20CL-AA1 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | Free Residual Chlorine |
| Range Options | 0–20 ppm / 0.0–20.0 ppm / 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Resolution | 0.01 ppm |
| Stability | ≤0.02 ppm/24 h |
| Temperature Compensation | 0–100 °C (PT1000, NTC10K, or Manual) |
| Output Signals | Dual Isolated 4–20 mA (Chlorine & Temperature, max. load 500 Ω) |
| Relay Outputs | 3 Programmable SPDT Relays (3 A / 250 V AC, NO contact, adjustable hysteresis) |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤7 W |
| Operating Environment | 0–50 °C, ≤85% RH |
| Enclosure Dimensions | 144 × 144 × 115 mm (H × W × D) |
| Panel Cutout | 138 × 138 mm |
| Ingress Protection | IP65 |
| User Interface | Bilingual (Chinese/English), Menu-Driven Navigation |
| Security | Password-Protected Configuration Access |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A10TR-AA1 |
| Price | USD 195 (FOB Shanghai) |
| Instrument Type | Online Turbidimeter |
| Measurement Ranges | 0–20 NTU, 0–400 NTU, 0–4000 NTU (custom ranges available) |
| Resolution | 0.01 NTU |
| Operating Temperature | 0–60 °C |
| Accuracy | ±1.0 % FS |
| Temperature Compensation | 0–100 °C (manual or automatic) |
| Output Signals | Isolated 4–20 mA (max. load 500 Ω), assignable to turbidity or temperature |
| Relay Outputs | 3 × SPDT relays (3 A / 250 V AC, NO contact), programmable high/low alarm thresholds with adjustable hysteresis |
| Power Supply | AC 220 V ±10 % / 50–60 Hz or DC 24 V ±10 % |
| Power Consumption | ≤7 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Environmental Rating | IP65 front panel |
| Relative Humidity | ≤85 % RH (non-condensing) |
| Brand | APURE |
|---|---|
| Model | A20PR-AA1 |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Output | Isolated 4–20 mA (dual optional), RS-485 Modbus RTU (optional) |
| Relay Outputs | 2 configurable SPDT relays (3 A/250 VAC), including self-cleaning function |
| Power Supply | AC 220 V or DC 24 V |
| Enclosure Dimensions | 144 × 144 × 115 mm (H × W × D) |
| Panel Cutout | 138 × 138 mm |
| Stability | ≤0.02 pH/24 h |
| Operating Environment | 0–60 °C |
| Power Consumption | ≤5 W |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | A30PR-AA1 |
| Price | USD 55 (FOB) |
| pH Range | 0.00–14.00 |
| ORP Range | −1999 to +1999 mV |
| pH Resolution | 0.01 |
| ORP Resolution | 1 mV |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±1 mV |
| Temperature Compensation | 0–100 °C (Manual / Automatic with PT1000 or NTC10K sensor) |
| Stability | ≤0.02 pH/24 h |
| Output | Isolated 4–20 mA (max. load 500 Ω) |
| Relay Output | 1 × SPDT, 3 A / 250 V AC (configurable high/low alarm with adjustable hysteresis) |
| Display | Custom segment LCD |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤15 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Dimensions (H×W×D) | 48×96×110 mm |
| Panel Cutout | 42×90 mm |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–100 °C (manual or automatic with PT1000/NTC10K sensor) |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions | 96 × 96 × 132 mm (H×W×D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA (conductivity/resistivity + temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Enclosure Rating | IP65 front panel |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | Apure |
|---|---|
| Model | A10CD-A / A10CD-S |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–60 °C |
| Resolution | 0.01 µS/cm |
| Output | Dual isolated 4–20 mA (conductivity/resistivity & temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Temperature Compensation | Automatic (PT1000 or NTC10K) or Manual |
| Display Language | Switchable between Chinese and English |
| Environmental Rating | 0–60 °C ambient, ≤85% RH non-condensing |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | A10CL-AA1 |
| Instrument Type | Online Controller |
| Measurement Parameter | Free Residual Chlorine |
| Measurement Range | 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Resolution | 0.01 ppm |
| Stability | ≤0.02 ppm/24 h |
| Temperature Compensation | 0–100 °C (Manual / PT1000 / NTC10K) |
| Output Signal | Isolated 4–20 mA (Max Load: 500 Ω) |
| Alarm Output | Dual SPDT Relays (3 A / 250 V AC, NO contact) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Dimensions (H×W×D) | 96×96×132 mm |
| Panel Cutout | 92.5×92.5 mm |
| Ingress Protection | IP65 |
| Brand | APURE |
|---|---|
| Model | A10PR-SA1-CCEP |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | pH 0.00–14.00 |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | 0–100 °C (Manual / PT1000 / NTC10K) |
| Output | Isolated 4–20 mA (pH or temperature selectable) |
| Communication | MODBUS RTU (RS-485) |
| Relay Outputs | 2 × SPDT, 3 A / 250 V AC, programmable high/low setpoints with adjustable hysteresis |
| Power Supply | AC 220 V, ≤7 W |
| Dimensions | 96 mm (H) × 96 mm (W) × 132 mm (D) |
| Panel Cutout | 92.5 mm × 92.5 mm |
| Operating Environment | 0–50 °C, ≤85% RH (non-condensing) |
| Data Logging | Real-time pH trend + 30-event relay alarm history |
| User Interface | Dual-language (Chinese/English), menu-guided navigation |
| Security | Password-protected configuration access |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KS-300 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, Dissolved Oxygen (DO), Conductivity, Temperature (derived from sensor fusion architecture) |
| Output Interface | 4–20 mA analog output, RS-485 Modbus RTU protocol |
| Power Supply | 12–24 VDC |
| IP Rating | IP67 enclosure |
| Operating Temperature Range | 0–50 °C |
| Sensor Mounting | Submersible or flow-through cell compatible |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RW-60 |
| Output Signal | 4–20 mA analog + RS485 Modbus RTU digital |
| Display | Backlit LCD with bilingual (English/Chinese) UI |
| Power Supply | 24 VDC ±15% |
| Environmental Rating | IP66 |
| Operating Temperature | –10 to 60 °C |
| Temperature Compensation | Automatic, high-precision thermistor-based |
| Relay Outputs | 2 configurable SPDT relays (max. 5 A @ 250 VAC) |
| Measurement Principle | Time-of-Flight (ToF) ultrasonic echo detection |
| Typical Range | 0.3 to 6.0 m (adjustable via software) |
| Repeatability | ±1 mm |
| Response Time | < 2 s (configurable) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TS-620 |
| Price | USD 685 (FOB Shanghai) |
| Product Type | Online |
| Measurement Range | Low-Turbidity Mode (0–0.5 NTU & 5–400 NTU) |
| Resolution | 0.01 NTU (low-turbidity), 0.1 NTU (high-turbidity) |
| Operating Temperature (Transmitter) | –20 to +55 °C |
| Accuracy | ±5% FS |
| Enclosure Rating | Transmitter IP65 |
| Process Pressure (Submersible) | ≤0.3 MPa |
| Output | 4–20 mA (4-wire, max. load 750 Ω) |
| Relay Outputs | 2 programmable SPDT relays (AC230 V, 2 A) |
| Digital Interface | RS485 with Modbus RTU protocol |
| Humidity | ≤85% RH (non-condensing) |
| Brand | APURE |
|---|---|
| Model | BT-280 |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±1% FS ±1 digit |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Output | Isolated 4–20 mA (configurable for pH, ORP, or temperature |
| Relay Outputs | 2 SPST relays (3 A / 250 VAC, NO contact |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Dimensions | 96 × 96 × 110 mm (H × W × D) |
| panel cutout | 91 × 91 mm |
| Operating Environment | 0–50 °C |
| Stability | ≤0.1 pH/24 h |
Show next