Empowering Scientific Discovery

Shanghai Qianxin Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ti2-A
Optical SystemCFI60 Infinity-Corrected
Intermediate Magnification1.0× / 1.5× (field-replaceable to 2.0×)
Focus MechanismMotorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled)
CondenserMotorized turret (TI2-C-TC-E) supporting 7 positions (ø37 mm × 4, ø39 mm × 3), including LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives
StageMotorized XY stage (TI2-S-SE-E): ±57 mm X, ±36.5 mm Y, max speed 25 mm/s
Objective Turret6-position motorized nosepiece with Perfect Focus System (PFS) and DIC compatibility
Epi-Fluorescence Filter Turret6-position motorized filter cube turret (TI2-F-FLT-E) with integrated shutter
IlluminationLED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp housing
Software IntegrationCompatible with NIS-Elements AR/VR/CV platforms
Environmental RatingIndoor use only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ts2R
Optical SystemCFI60 Infinity-Corrected
Observation ModesBrightfield, Phase Contrast (including TMC), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Fluorescence Epi-Illumination, Spindle Observation
IlluminationHigh-Brightness White LED Transmitted Light (with Homogenizing Lens), LED Epi-Illumination (up to 4 interchangeable units
wavelengths385, 455, 470, 505, 525, 590, 625 nm)
Eyepiece Options10× (22 mm FOV), 12.5× (16 mm), 15× (14.5 mm)
Binocular TubeSiedentopf-type, interpupillary distance 50–75 mm, tilt angle 35° (standard) or 15–45° (ergonomic)
Camera Port Split Ratios100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50
Focus MechanismObjective nosepiece-driven Z-movement
coarse focus5.0 mm/rev, fine focus: 0.1 mm/rev
Objective Turret6-position, with DIC prism slots
CondenserRotating condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers
StageFlat stage (260 × 300 mm)
Stage AdaptersC-S-HP35 (35 mm dish), C-S-HLP100 (100 mm dish), C-S-HT (Terasaki plates & Ø65 mm dishes), C-S-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide), C-S-HLS (circular slide kit), TC-S-HA (acrylic stage plate)
Fluorescence AccessoriesMotorized filter cube turret (body-integrated, noise-reduction design)
Dimensions (W×D×H)286 × 466 × 542 mm
Weight~17–18 kg
Power Supply100–240 V AC, <0.65 A
Power Consumption30 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ti2-E
TypeInverted Research Microscope with Motorized Precision Optomechanics
Optical SystemCFI60 Infinity-Corrected, Field Number 22 (Eyepiece), Field Number 16 (Camera Port)
Intermediate Magnification1.0× / 1.5× (field-upgradable to 2.0×)
Focus DriveMotorized coarse/fine focusing, 10 mm travel, minimum step size 0.01 µm (encoder-controlled)
Condenser TurretMotorized 7-position (TI2-C-TC-E), supporting LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives
Objective Nosepiece5-position motorized with Perfect Focus System (PFS) and correction collar control
Epi-Fluorescence Filter Turret6-position motorized (TI2-F-FLT-E) with integrated shutter
StageMotorized XY stage (±57 mm X, ±36.5 mm Y), max speed 25 mm/s, magnetic sample holder
IlluminationLED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp
Software CompatibilityNIS-Elements AR/C/VR, supports FDA 21 CFR Part 11 compliance modules, GLP/GMP audit trail logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ti2-U
Optical SystemCFI60 Infinity-Corrected
Intermediate Magnification1.0× / 1.5× (field-replaceable to 2.0×)
Focus MechanismMotorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled)
CondenserMotorized turret (7-position, supports LWD/ELWD/CLWD/HNA/NAMC objectives)
StageMotorized XY stage (±57 mm X, ±36.5 mm Y, max speed 25 mm/s)
Nosepiece6-position motorized objective revolver with Perfect Focus System (PFS) and DIC compatibility
Epi-Fluorescence Turret6-position motorized filter turret with integrated shutter
IlluminationLED-based transmitted illumination (TI2-D-LHLED) and fiber-coupled epi-fluorescence modules
Environmental Rating0–40 °C, ≤60% RH (non-condensing), indoor use only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ts2R-FL
Optical SystemCFI60 Infinity-Corrected
Observation ModesBrightfield, Phase Contrast (including TIRF-capable phase), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Spindle Observation, Epifluorescence
IlluminationHigh-Intensity White LED Transmitted Light (with Köhler illumination and built-in fly-eye lens)
wavelengths385, 455, 470, 505, 525, 590, 625 nm)
Eyepiece Options10×/22, 12.5×/16, 15×/14.5 field number
Trinocular Port Split Ratios100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50
Focus MechanismObjective nosepiece-driven Z-axis movement (8 mm upward, 3 mm downward travel)
coarse focus5.0 mm/rev, fine focus: 0.1 mm/rev
Nosepiece6-position revolver with DIC prism slots
CondenserMulti-position condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers
StageFlat stage (260 × 300 mm)
Fluorescence AccessoriesMotorized filter cube turret (with noise-reduction mechanism)
Dimensions (W×D×H)286 × 466 × 542 mm
Weight~17–18 kg
Power Supply100–240 V AC, <0.65 A, 30 W max
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ji
Optical SystemCFI Infinity Optics
Microscope TypeInverted Fluorescence Microscope
Observation ModesBrightfield & Epi-Fluorescence
Field Number25
Camera7.8 MP Monochrome CMOS Sensor
Bit Depth12-bit / 8-bit
Max Frame Rate18 fps
Output Resolution2800 × 2800 pixels
Focus DriveMotorized PFS (Perfect Focus System)
Focus Travel~10 mm
Max Focus Speed2.5 mm/sec
PFS MethodInfrared Projection-Based Focus Maintenance
Stage Travel (X/Y)±59 mm / ±39.5 mm
Max Stage Speed~25 mm/sec
Objective Turret6-position, Motorized
Filter Cube Capacity6 positions (wide-field compatible)
Filter Turret DriveMotorized
Light SourceD-LEDI2 LED Fluorescence Illuminator
IlluminationKöhler LED Transmitted Light
InterfaceUSB 3.0 (SuperSpeed), USB-B connector
Input Voltage100–240 VAC ±10%, 50/60 Hz
Power Consumption320 W
ComplianceUL, CE, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ts2-FL
Optical SystemCFI60 Infinity-Corrected
Observation ModesBrightfield, Phase Contrast (T-PH), Differential Interference Contrast (DIC)-like Relief Contrast, Epifluorescence
IlluminationHigh-Brightness White LED Transmitted Light + Modular LED Epifluorescence (385, 455, 470, 505, 525, 560, 590, 625 nm)
Eyepiece Field Number22 (10×), 16 (15×), 12.5 (20×)
Tube Angle45°, Interpupillary Distance: 50–75 mm (Siedentopf), Trinocular Port (100/0 or 0/100 beam splitter)
Focus Travel8.5 mm total (7 mm upward, 1.5 mm downward)
Coarse Focus37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque
Objective Turret5-Position
CondenserELWD (NA 0.3, WD 75 mm) with Pre-centered and Centerable Phase Contrast Sliders (for 10×, 20×, 40×) and Relief Contrast Sliders (dual-side configuration required)
StageFixed Plate Stage (170 × 247 mm) with Acrylic Circular Cover Slip
Compatible with Multiple Sample HoldersCS-HP35 (35 mm dish), CS-HLP100 (100 mm dish), CS-HT (Terasaki plate & Ø65 mm dish), CS-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal holder for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide holder), C-S-HLS (circular cover slip kit)
Fluorescence AttachmentMotorized Filter Cube Turret (3 positions + brightfield slot), Integrated Noise-Reduction Mechanism, Optional Light Shield
Dimensions (W×D×H)236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL)
Weight~13 kg (Ts2), ~14.5 kg (Ts2-FL)
Power Supply100–240 VAC ±10%, 50/60 Hz, 0.35 A
Power Consumption15 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNikon
OriginJapan
ModelECLIPSE Ts2
Optical SystemCFI60 Infinity-Corrected
Observation ModesBrightfield, Phase Contrast (including Plan Apochromat Phase), DIC-like Relief Contrast*¹
Fluorescence CapabilityYes (Ts2-FL variant)
IlluminationHigh-Brightness White LED Transmitted Light (with Köhler illumination via built-in fly-eye lens)
Eyepiece Angle45°, Interpupillary Distance: 50–75 mm (Siedentopf), Port Split: 100/0 or 0/100
Focusing MechanismObjective Nosepiece Movement (7 mm up / 1.5 mm down), Coarse Focus: 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque
Objective Turret5-Position
CondenserELWD (NA 0.3, WD 75 mm)
StageFlat Stage (170 × 247 mm)
Dimensions (W×D×H)236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL)
Weight~13 kg (Ts2), ~14.5 kg (Ts2-FL)
Power Supply100–240 V AC ±10%, 50/60 Hz, 0.35 A
Power Consumption15 W