- All
- Favorite
- Popular
- Most rated
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-A |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (TI2-C-TC-E) supporting 7 positions (ø37 mm × 4, ø39 mm × 3), including LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Stage | Motorized XY stage (TI2-S-SE-E): ±57 mm X, ±36.5 mm Y, max speed 25 mm/s |
| Objective Turret | 6-position motorized nosepiece with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Filter Turret | 6-position motorized filter cube turret (TI2-F-FLT-E) with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp housing |
| Software Integration | Compatible with NIS-Elements AR/VR/CV platforms |
| Environmental Rating | Indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TMC), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Fluorescence Epi-Illumination, Spindle Observation |
| Illumination | High-Brightness White LED Transmitted Light (with Homogenizing Lens), LED Epi-Illumination (up to 4 interchangeable units |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10× (22 mm FOV), 12.5× (16 mm), 15× (14.5 mm) |
| Binocular Tube | Siedentopf-type, interpupillary distance 50–75 mm, tilt angle 35° (standard) or 15–45° (ergonomic) |
| Camera Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-movement |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Objective Turret | 6-position, with DIC prism slots |
| Condenser | Rotating condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Stage Adapters | C-S-HP35 (35 mm dish), C-S-HLP100 (100 mm dish), C-S-HT (Terasaki plates & Ø65 mm dishes), C-S-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide), C-S-HLS (circular slide kit), TC-S-HA (acrylic stage plate) |
| Fluorescence Accessories | Motorized filter cube turret (body-integrated, noise-reduction design) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A |
| Power Consumption | 30 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-E |
| Type | Inverted Research Microscope with Motorized Precision Optomechanics |
| Optical System | CFI60 Infinity-Corrected, Field Number 22 (Eyepiece), Field Number 16 (Camera Port) |
| Intermediate Magnification | 1.0× / 1.5× (field-upgradable to 2.0×) |
| Focus Drive | Motorized coarse/fine focusing, 10 mm travel, minimum step size 0.01 µm (encoder-controlled) |
| Condenser Turret | Motorized 7-position (TI2-C-TC-E), supporting LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Objective Nosepiece | 5-position motorized with Perfect Focus System (PFS) and correction collar control |
| Epi-Fluorescence Filter Turret | 6-position motorized (TI2-F-FLT-E) with integrated shutter |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y), max speed 25 mm/s, magnetic sample holder |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp |
| Software Compatibility | NIS-Elements AR/C/VR, supports FDA 21 CFR Part 11 compliance modules, GLP/GMP audit trail logging |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-U |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (7-position, supports LWD/ELWD/CLWD/HNA/NAMC objectives) |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y, max speed 25 mm/s) |
| Nosepiece | 6-position motorized objective revolver with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Turret | 6-position motorized filter turret with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED) and fiber-coupled epi-fluorescence modules |
| Environmental Rating | 0–40 °C, ≤60% RH (non-condensing), indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TIRF-capable phase), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Spindle Observation, Epifluorescence |
| Illumination | High-Intensity White LED Transmitted Light (with Köhler illumination and built-in fly-eye lens) |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10×/22, 12.5×/16, 15×/14.5 field number |
| Trinocular Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-axis movement (8 mm upward, 3 mm downward travel) |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Nosepiece | 6-position revolver with DIC prism slots |
| Condenser | Multi-position condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Fluorescence Accessories | Motorized filter cube turret (with noise-reduction mechanism) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A, 30 W max |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ji |
| Optical System | CFI Infinity Optics |
| Microscope Type | Inverted Fluorescence Microscope |
| Observation Modes | Brightfield & Epi-Fluorescence |
| Field Number | 25 |
| Camera | 7.8 MP Monochrome CMOS Sensor |
| Bit Depth | 12-bit / 8-bit |
| Max Frame Rate | 18 fps |
| Output Resolution | 2800 × 2800 pixels |
| Focus Drive | Motorized PFS (Perfect Focus System) |
| Focus Travel | ~10 mm |
| Max Focus Speed | 2.5 mm/sec |
| PFS Method | Infrared Projection-Based Focus Maintenance |
| Stage Travel (X/Y) | ±59 mm / ±39.5 mm |
| Max Stage Speed | ~25 mm/sec |
| Objective Turret | 6-position, Motorized |
| Filter Cube Capacity | 6 positions (wide-field compatible) |
| Filter Turret Drive | Motorized |
| Light Source | D-LEDI2 LED Fluorescence Illuminator |
| Illumination | Köhler LED Transmitted Light |
| Interface | USB 3.0 (SuperSpeed), USB-B connector |
| Input Voltage | 100–240 VAC ±10%, 50/60 Hz |
| Power Consumption | 320 W |
| Compliance | UL, CE, RoHS |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (T-PH), Differential Interference Contrast (DIC)-like Relief Contrast, Epifluorescence |
| Illumination | High-Brightness White LED Transmitted Light + Modular LED Epifluorescence (385, 455, 470, 505, 525, 560, 590, 625 nm) |
| Eyepiece Field Number | 22 (10×), 16 (15×), 12.5 (20×) |
| Tube Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Trinocular Port (100/0 or 0/100 beam splitter) |
| Focus Travel | 8.5 mm total (7 mm upward, 1.5 mm downward) |
| Coarse Focus | 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) with Pre-centered and Centerable Phase Contrast Sliders (for 10×, 20×, 40×) and Relief Contrast Sliders (dual-side configuration required) |
| Stage | Fixed Plate Stage (170 × 247 mm) with Acrylic Circular Cover Slip |
| Compatible with Multiple Sample Holders | CS-HP35 (35 mm dish), CS-HLP100 (100 mm dish), CS-HT (Terasaki plate & Ø65 mm dish), CS-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal holder for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide holder), C-S-HLS (circular cover slip kit) |
| Fluorescence Attachment | Motorized Filter Cube Turret (3 positions + brightfield slot), Integrated Noise-Reduction Mechanism, Optional Light Shield |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2 |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including Plan Apochromat Phase), DIC-like Relief Contrast*¹ |
| Fluorescence Capability | Yes (Ts2-FL variant) |
| Illumination | High-Brightness White LED Transmitted Light (with Köhler illumination via built-in fly-eye lens) |
| Eyepiece Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Port Split: 100/0 or 0/100 |
| Focusing Mechanism | Objective Nosepiece Movement (7 mm up / 1.5 mm down), Coarse Focus: 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) |
| Stage | Flat Stage (170 × 247 mm) |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 V AC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
Show next