| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE LV100ND POL/DS |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | 12 V–50 W Halogen Lamp (LV-HL50W) with Built-in DC Transformer |
| Brightness | >100 W Equivalent |
| Condenser | LV-CUD Universal Dry Condenser (NA 0.9), Optional Swing-Out Polarizing Condenser |
| Stage | Precision Rotatable Circular Stage (0–360°, 1° graduation, 0.1° vernier reading, 45° click-stop) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (Coarse: 14 mm/rev |
| Fine | 0.1 mm/rev |
| Minimum Readout | 1 µm) |
| Eyepieces | CFI 10×, FOV 22 mm, CM-type with Crosshair & Micrometer Scale |
| Trinocular Tube | P-TT3 for Polarizing Microscopy, Equipped with Bertrand Lens (Focusable & Centerable), Removable Analyzer, Switchable Orthoscopic/Conoscopic Observation, λ/4 Plate & Compensator Slots |
| Analyzer | 360° Rotatable, 0.1° Graduation |
| Objective Turret | Centerable 5-Position Nosepiece with DIN Compensator Slot |
| Polarizers | C-SP Simple Polarizer, One-Touch Swing-Out Polarization Control |
| Objectives | CFI Achromat P 4×, P 10×, LWD P 20×, P 40×, P 100× Oil |
| Dispersion Objectives | CFI Achromat R-DS 10×, CFI Plan Achromat C-DS 10×, CFI Plan Fluor R-DS 40× |
| Compensators | P-CL1/4λ Plate, Quartz Wedge, or Sénarmont Compensator (Insertable into Intermediate Tube) |
| Filter Holder | IF546/12 Interference Filter (Ø45 mm) |
| Power Consumption | 75 W (1.2 A) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE LV100N / E200POL |
| Optical System | CFI60 Infinity-Corrected |
| Eyepieces | Standard 10× (FOV 22 mm), CM-type with 90° crosshair and micrometer scale |
| Basic set | 10× (FOV 20 mm) |
| Tube | Binocular P-TB2 / Trinocular P-TT3 (LV100N) |
| Intermediate Tube | Built-in focusable Bertrand lens (removable from optical path) |
| Analyzer | 360° rotatable dial, minimum angular resolution 0.1° |
| Objective Turret | Fixed 4-position |
| Focus Mechanism | Coarse/fine adjustment — fine drive: 0.2 mm/rev, coarse travel: 37.7 mm/rev |
| minimum step size | 2 µm (left-hand fine knob) |
| Stage | 160 mm circular graduated stage, 1° increments with vernier reading to 0.1° |
| Illumination | Pre-centered 6 V–30 W halogen lamp with continuously variable intensity control |
| Objectives | CFI Achromat P 4×, 10×, LWD P 20×, 40×, 100× Oil (all strain-free, polarized-light optimized) |
| Condenser | Strain-free swing-out condenser |
| Polarizer | Mounted at condenser base |
| Compensators | Standard λ/4 and tint plates |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIM E |
| Resolution (XY) | ~115 nm |
| Resolution (Z, 3D-SIM) | ~300 nm |
| Imaging Speed | ~1 frame/sec |
| Field of View | 66 µm × 66 µm |
| Objective Compatibility | High-NA objectives up to NA 1.49 |
| Modality | Structured Illumination Microscopy (SIM) with integrated confocal capability |
| 3D Reconstruction Modes | Slice and Stack |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-STORM |
| XY Resolution | ~20 nm |
| Z Resolution | ~50 nm |
| Imaging Modes | 2D-STORM (n-STORM, c-STORM), 3D-STORM (n-STORM, c-STORM), 3D-Stack |
| Maximum Field of View | 80 µm × 80 µm |
| Frame Rate | up to 500 Hz |
| Multicolor Capability | up to 3 channels |
| Compatible Lasers | LU-NV Series (405/488/561/647 nm), LUD-H Series (405/488/561/640 nm) |
| Compatible Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope |
| Autofocus System | Perfect Focus System (PFS) with encoder-based motorized XY stage and Piezo Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC oil (NA 1.49), CFI HP Plan Apochromat VC 100X oil (NA 1.40) |
| Camera Options | ORCA-Fusion BT sCMOS (Hamamatsu), iXON Ultra DU-897U EMCCD (Andor) |
| Software | NIS-Elements AR / NIS-Elements C (optional), NIS-A 6D and N-STORM Analysis Module (required) |
| Operating Temperature | 20–25 °C (±0.5 °C) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX with NSPARC |
| Detector Type | NSPARC (Nikon Spatially Resolved Array Photon Counter) |
| Lateral Resolution | 100 nm |
| Axial Resolution | 300 nm |
| Scan Head Options | AX-SHS (Galvo-only), AX-SHR (Galvo + Resonant) |
| Field of View | 25 mm |
| Max Image Resolution | 8192 × 8192 pixels |
| Resonant Scan Speed | up to 720 fps @ 2048 × 16 px |
| Galvo Scan Speed | 10 fps @ 512 × 512 px |
| Pixel Dwell Time Range | 0.2 ms – 10 µs |
| Scan Modes | Unidirectional, Bidirectional, Line Scan, Rolling Average, Line Average |
| Real-time AI Denoising | Denoise.ai integrated |
| Emission Filter Capacity | Up to 7 positions (405/445/488/514/561/594/640 nm) |
| Excitation Compatibility | Multi-laser (405–640 nm) |
| Detector Architecture | SPPC (Single-Pixel Photon Counting) Array |
| Rotation Capability | ±180° image rotation |
| Software Platform | NIS-Elements AR/C |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIMS |
| Lateral Resolution (XY, FWHM) | 86 nm (TIRF-SIM), 115 nm (3D-SIM) |
| Axial Resolution (Z, FWHM) | 269 nm (3D-SIM) |
| Max Imaging Speed | 15 fps (TIRF-SIM/2D-SIM, 2 ms exposure) |
| Reconstruction Image Size | 1024 × 1024 or 2048 × 2048 pixels |
| Imaging Modes | TIRF-SIM, 2D-SIM, 3D-SIM (single-frame & time-series reconstruction) |
| Multicolor Capability | Up to 6 channels, simultaneous dual-color acquisition |
| Compatible Laser Units | LU-NV (std: 405/488/561/640 nm |
| opt | 445 nm), LUD-HV (std: same |
| opt | 445/515 nm), Ziva Light Engine (405/446/476/518/545/637 nm) |
| Compatible Microscope Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope with Perfect Focus System (PFS), encoded motorized XY stage, and piezo-driven Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC Oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC Oil (NA 1.49), CFI SR Plan Apochromat IR 60XC WI (NA 1.27), CFI SR Plan Apochromat IR 60XAC WI (NA 1.27), CFI Plan Apochromat Lambda 60XC (NA 0.95), CFI Plan Apochromat Lambda 40XC (NA 0.95) |
| Camera | ORCA-Fusion BT sCMOS (Hamamatsu Photonics K.K.) |
| Software | NIS-Elements AR (with NIS-A 6D and N-SIM analysis modules required), NIS-Elements C (for AX/AX R confocal systems) |
| Operating Environment | 20–28 °C (±1.5 °C) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE LV100N POL |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | 12 V / 50 W Halogen (Transmitted), Optional 12 V / 100 W Halogen (Reflected) |
| Focus Travel | 30 mm |
| Coarse Focus | 14 mm/rev |
| Fine Focus | 0.1 mm/rev, Minimum Graduation: 1 µm |
| Eyepieces | Widefield 10× (FOV 22 mm), Crosshair & Micrometer Scale |
| Observation Tubes | P-TT3 Trinocular, P-TB2 Binocular with Built-in Bertrand Lens (Removable, Centerable) |
| Analyzer | 360° Rotatable, Graduation: 0.1° |
| Polarizer | Fixed in Condenser Base with Scale |
| Condenser | Stress-Free Swing-Out Type, NA 0.9 Achromat |
| Objective Turret | Centerable Five-Position |
| Stage | Precision Circular Rotatable Stage (0–360°, 1° Increment, Click Stops at 45°), Mechanical XY Stage (35 × 25 mm, Vernier 0.1 mm) |
| Compensator Slots | Intermediate Tube for λ/4 Plate, Full-Wave Plate, Quartz Wedge, Senarmont Compensator |
| Reflected Light | LV-UEPI-N Universal Epi-Illuminator |
| Power Consumption | 75 W (1.2 A) |
| Weight | ~17 kg (Standard Trinocular Configuration) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX R MP |
| Optical System | Infinity-Corrected |
| Frame Type | AX-FNSP (Upright) / AX-FNGP (Gantry) |
| Focus Unit | AX-FN Motorized Coaxial Coarse/Fine Focus |
| Focus Travel | +13 mm / –2 mm |
| Minimum Step Size | 0.02 µm |
| Focal Plane Height | 400 mm above Vibration-Isolation Table |
| Controller | AX-FNCTL Main Controller + AX-FNHC Hub Controller (manages objective focus, transmitted illumination, joystick, motorized epi-fluorescence filter turret, ergonomic motorized quad-port head, DSC zoom port) |
| Scanning | 2K Resolution Resonant Scanner |
| Imaging Mode | Multiphoton Excitation + Confocal Detection |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX / AXR |
| Type | Upright Laser Scanning Confocal Microscope System |
| Optical Architecture | Dual-galvo scanning with resonant scanner option |
| Detection | GaAsP hybrid detectors (HyD) with spectral unmixing capability |
| Objective Compatibility | Nikon CFI Plan Apo λ series, 10×–100×, oil/water/glycerol immersion |
| Laser Lines | 405 nm, 488 nm, 561 nm, 640 nm (standard), optional UV and IR lines |
| Maximum Imaging Speed | Up to 30 fps at 512 × 512 resolution (resonant mode) |
| Z-resolution | < 0.1 µm (with piezo stage and deconvolution) |
| Software Platform | NIS-Elements AR/CV with AI-powered denoising and 3D/4D reconstruction modules |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE LV100N Ci-POL |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | 6 V / 30 W Halogen Lamp with Built-in Transformer |
| Focus Travel | 30 mm (Coarse: 9.33 mm/rev |
| Fine | 0.1 mm/rev |
| Precision | 1 µm increments) |
| Eyepieces | Widefield 10× (22 mm FOV) |
| Trinocular Tube | P-TT3 for Polarization |
| Binocular Tube | P-TB2 |
| Bertrand Lens | Focusing, Removable, Switchable for Conoscopic Observation |
| Analyzer | 360° Rotatable Polarizer, 0.1° Graduation |
| Objective Turret | 5-Position, Centerable, DIN-Standard |
| Stage | Ball-Bearing Rotating Stage (360°, 1° Increment, Lockable) |
| Mechanical XY Translation (35 × 25 mm, Vernier Scale | 0.1 mm) |
| Condenser | Stress-Free Swing-Out Achromat, NA 0.9 |
| Polarizer | Uncalibrated Linear Polarizer |
| Objectives | CFI Achromat P 4×, 10×, LWD 20×, 40×, 100× Oil |
| Accessories | Insertable λ/4 Plate, Full-Wave Plate, Quartz Wedge, Senarmont Compensator |
| Power Consumption | 38 W |
| Weight | ~14 kg (Standard Binocular Configuration) |
Show next