Empowering Scientific Discovery

Shanghai Xianjian Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXianjian
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHYP-304
QuotationUpon Request
Temperature Control RangeAmbient to 600 °C
Temperature Accuracy±1 °C
Heating Rate30 °C/min (average)
Number of Digestion Positions4
Digestion Tube Capacity250 mL
Nitrogen Determination Range0.1–240.0 mg N
Cycle Time45 min/batch
Display2.5-inch Blue LCD (simultaneous real-time temperature & hold time with countdown timer)
Heating ElementCeramic Core Heater
Insulation MethodSplit Air-Channel Thermal Isolation
Exhaust Sealing MaterialPolytetrafluoroethylene (PTFE)
Safety FeaturesProgrammable Upper-Temperature Limit with Auto-Cut-off and Audible Alarm
Control ModesDual-mode programmable ramping — linear and curve-based heating profiles
Rated Power1200 W
Voltage/Frequency220 V ±10%, 50–60 Hz
Dimensions (W×D×H)440 × 310 × 190 mm
Net Weight11 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXianjian
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Measurement Range0.1–240.0 mg N per sample
Distillation Time3–8 min per sample
AccuracyRelative Error ≤ 0.3%
RepeatabilityParallel Difference ≤ 0.2%
Sample Weight Capacity≤ 8.0 g (solid), ≤ 30.0 mL (liquid)
Nitrogen Recovery Rate≥ 99.5%
Power Consumption1700 W
Dimensions (L×W×H)580 × 430 × 750 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXianjian
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSLQ-200
PricingUpon Request
PrincipleAcid-Alkali Digestion (AOAC 962.09 / ISO 5498 / GB/T 6434)
Sample Capacity1–6 samples per run
Sample Mass Range0.5–3.0 g
Measurement Range0–100% crude fiber
Repeatability≤0.4% RSD
Total Cycle Time≤90 min
Heating MethodSemi-circular Silicon Carbide Heaters (Individually Controllable)
Temperature ControlManual/Automatic Dual Mode, 0–200 °C
Heating Power AdjustmentContinuously Variable
Sealing SystemDual PTFE Isolation Gasket (Top & Bottom)
Liquid DeliveryPressure-Driven Injection (vs. gravity-fed)
Reagent PreheatingAutomatic Thermostatic Control with Over-Temperature Protection
Corrosion ResistanceCertified for H₂SO₄, NaOH, acetone, and other standard digestion solvents
Display4.3-inch HD Capacitive Touchscreen
Filtration SystemHigh-Flow Vacuum Filtration with Chemically Resistant Components
Power Supply220 V ±10%, 50–60 Hz
Rated Power1600 W (main unit), 1350 W (anti-dry-boil digestion vessel)
Dimensions (W×D×H)560 × 460 × 660 mm
Net Weight45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXianjian
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of ManufactureDomestic (China)
ModelSLQ-6A
PricingAvailable Upon Request
Measurement PrincipleAcid-Alkali Sequential Digestion (AOAC 978.10 / ISO 5498 / GB/T 6434)
Sample Throughput1–6 samples per run
Sample Mass Range0.5–3.0 g
Measuring Range0.00–99.99% (dry basis)
Repeatability≤0.4% RSD
Total Cycle Time≤90 min
Heating SystemIndividual Semi-Circular Silicon Carbide Heaters (Independent Temperature Control per Vessel)
Sealing MechanismDual PTFE Isolation Gasket (Top & Bottom)
Liquid DeliveryPressurized Injection System
Reagent PreheatingAutomatic PID-Controlled Constant-Temperature Heating with Over-Temperature Protection
Chemical ResistanceFull Compatibility with 1.25 M H₂SO₄, 1.25 M NaOH, Acetone, and Neutral Solvents
Power Supply220 V ±10%, 50–60 Hz
Rated Power1600 W (Main Unit), 1350 W (Anti-Dry-Boil Digestion Module)
Dimensions (W×D×H)560 × 460 × 660 mm
Net Weight45 kg
ComplianceDesigned to support AOAC Official Method 978.10, ISO 5498:2022, and GB/T 6434–2007 workflows