Fiber Analyzer
Filter
Showing all 22 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A220 |
| Pricing | Available Upon Request |
| Sample Capacity | 24 positions |
| Throughput | ≥96 samples per day |
| Operating Temperature | 100 °C |
| Power Supply | 220 V, 50/60 Hz, 1500 W |
| Weight | 20 kg (45 lbs) |
| Filter Bag Pore Size | 30 µm |
| Chemical Resistance | Compatible with 75% sulfuric acid and neutral/basic detergents |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FBS6 |
| Price Range | USD 2,700 – 6,800 (FOB Hamburg) |
| Heating Capacity | 1 position |
| Sample Throughput | 6 samples per run |
| Max Temperature | 425 °C |
| Power Supply | 230 V AC, 50–60 Hz |
| Power Consumption | 450 W |
| Dimensions (W×D×H) | 250 × 230 × 600 mm |
| Net Weight | 12 kg |
| Method Principle | Filter Bag-Based Acid-Base Digestion per AOAC 962.09 and ISO 6865 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | FT12 |
| Price Range | USD 25,000 – 50,000 |
| Sample Capacity | 1–12 samples per batch |
| Heating System | Crystalline ceramic heater |
| Programmable Methods | 10 |
| Reagent Dispensing | Automated acid/alkali/water/waste handling |
| Filtration | Pneumatically controlled FibreBag® filtration |
| Safety Features | Closed-system operation, audible/visual error alerts |
| Cooling Water Requirement | 5 L/min (on-demand) |
| Power Supply | 230 V AC, 50 Hz |
| Power Consumption | 1900 W |
| Dimensions | 330 × 650 × 860 mm |
| Weight | 42 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | F2000 |
| Sample Capacity | 24+ positions per batch |
| Temperature Control Accuracy | ±0.1°C |
| Repeatability | ≤0.5% RSD |
| Daily Throughput | ≥96 samples (4 batches) |
| Power Supply | AC 220±10 V, 50±1 Hz |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 520 × 450 × 510 mm |
| Net Weight | 52 kg |
| Compliance | GB/T 6434-2006, GB/T 20805-2006, GB/T 20806-2006, GB/T 5515-2008, GB/T 8310-2013, GB/T 5009.10-2003 |
| Brand | Hanon |
|---|---|
| Model | F800 |
| Origin | Shandong, China |
| Type | Semi-Automatic Fiber Analyzer |
| Compliance | GB/T 5515, GB/T 6434 |
| Sample Capacity | 6 samples/batch |
| Sample Weight Range | 0.5–3 g |
| Detection Range | 0.1–100% |
| Repeatability | ≤0.4% (for crude fiber <10%), ≤1% (for crude fiber ≥10%) |
| Heating Method | Integrated Infrared Heating |
| Preheating Time (Distilled Water) | 10–12 min |
| Boiling Time | 13–15 min |
| Rated Power | 2.2 kW |
| Voltage/Frequency | 220 VAC ±10%, 50 Hz |
| Dimensions | 776 × 476 × 644 mm |
| Optional Accessory | F800-B Cold Extraction Unit |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-CXW |
| Price | USD 3,500 (FOB Qingdao) |
| Detection Range | 0–100% |
| Sample Mass | 0.5–3.0 g |
| Batch Capacity | 6 samples |
| Temperature Control Accuracy | ±0.1 °C |
| Repeatability | ≤0.4% (crude fiber <10%) |
| Heating Element | Semi-circular silicon carbide heater |
| Display | 7-inch color TFT touchscreen |
| Liquid Delivery | Programmable, fully automated acid/alkali reagent injection |
| Filtration System | High-suction corrosion-resistant diaphragm pump with integrated back-blow function |
| Safety Features | Overflow prevention logic, dry-run protection, external reagent preheating reservoir |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Total Power | 1500 W (main unit) + 1200 W (digestion block) |
| Dimensions (W×D×H) | 620 × 440 × 655 mm |
| Weight | 45 kg |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-CXW |
| Detection Range | 0–100% |
| Sample Weight | 0.5–3.0 g |
| Batch Capacity | 6 samples |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Element | Semi-circular Silicon Carbide Heater |
| Repeatability | ≤0.4% (crude fiber <10%), ≤1% (crude fiber ≥10%) |
| Display | 7-inch Color Touchscreen |
| Liquid Delivery | Programmable Automatic Dispensing |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Total Power | 1500 W (main unit) + 1200 W (anti-dry-boil digestion vessel) |
| Dimensions | 620 × 440 × 655 mm |
| Weight | 45 kg |
| Brand | OPISIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FB-120 |
| Price | Upon Request |
| Capacity | 6 samples per batch |
| Dimensions (W×H×D) | 655 × 325 × 475 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % RH |
| Voltage | 190–240 VAC, 50–60 Hz |
| Max. Power Consumption | 2000 W |
| Fiber Method | Crude Fiber (CF) per Weende and AOAC/ISO-compliant protocols |
| Hydrolysis Compatibility | Samples with fat content 0.1–100 %, sample mass 0.5–3 g |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-300 |
| Sample Capacity | 27 per batch |
| Throughput | 108 CF / 135 NDF / 162 ADF samples per day |
| Sample Mass Range | 0.1–2.0 g |
| Measurement Range | 0–100% |
| Repeatability | ≤ 0.5% |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Color LCD touchscreen with bilingual (EN/CN) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Safety Systems | Dual liquid-level sensors, real-time temperature & pressure monitoring, mechanical pressure relief valve, lid interlock sensor |
| Software Integration | LabConnect LIMS-ready, optional balance & barcode scanner interface |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 720 × 650 × 780 mm |
| Weight | 85 kg |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-310 |
| Sample Capacity | 27 per batch |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Repeatability | ≤0.5% RSD |
| Measurement Range | 0–100% |
| Display | Color LCD touchscreen with bilingual (English/Chinese) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Reagent Ports | 4 independent external connections (acid, base, neutral detergent, acid detergent) + dedicated amylase reservoir |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | F20 |
| Pricing | Available Upon Request |
| Measurement Principle | Acid-Base Digestion per National Standards (GB/T 6434, GB/T 5515, GB/T 10378, GB 5009.10) |
| Filtration Technology | Disposable Filter Bag System (Standard Pore Size: 25 µm |
| Optional | 15 µm or 10 µm) |
| Batch Capacity | 1–30 samples/batch |
| Daily Throughput | 90–180 samples |
| Temperature Range | Ambient to 100 °C |
| Sample Mass per Bag | 0.1–5.0 g |
| Temperature Control Accuracy | ±0.1 °C |
| Stirring Mechanism | Patented Intermittent Agitation (15 rpm, 1-min cycle) |
| Repeatability | ≤0.5% RSD |
| Power Supply | AC 220 V / 50 Hz |
| Safety Design | High-pressure sealed digestion chamber, no cooling water required, no internal glass components, lab-bench compatible (no fume hood needed) |
| Brand | Sonnen |
|---|---|
| Model | F22 |
| Application | Crude Fiber, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Acid Detergent Lignin (ADL), and Insoluble Dietary Fiber analysis |
| Principle | Standardized acid-base digestion (AOAC 978.10, AOAC 2002.04, ISO 13906, GB/T 6434–2022) |
| Filtration Technology | 25 µm pore-size filter bags (optional 15 µm or 10 µm) |
| Batch Capacity | 30 samples per run |
| Temperature Range | Ambient to 100 °C |
| Sample Mass per Bag | 0.1–5.0 g |
| Repeatability | ≤0.5% RSD |
| Temperature Control Accuracy | ±0.1 °C |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 373 × 500 × 450 mm |
| Weight | 25 kg |
| Safety | High-pressure sealed digestion chamber, no cooling water required, no glass components, operational in standard lab environment without fume hood |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | CXC-06 |
| Price | USD 1,300 (FOB) |
| Sample Capacity | 6 samples per run |
| Repeatability Error | ≤0.4% absolute (for crude fiber content <10%) |
| Total Digestion & Filtration Time | ~100 min (acid digestion: 40 min |
| alkaline digestion | 40 min |
| filtration & washing | ~20 min) |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 2800 W |
| Cooling Water Requirement | inlet water temperature <20 °C |
| Dimensions (W×D×H) | 670 mm × 450 mm × 670 mm |
| Net Weight | 30 kg |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CXC-06 |
| Power | 2800 W |
| Voltage/Frequency | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 670 × 450 × 670 mm |
| Weight | 30 kg |
| Sample Capacity | 6 samples per run |
| Analyte | Crude fiber content in feed, grain, forage, food, and agricultural products |
| Digestion Time | ~100 min per batch (acid digestion: 40 min |
| alkaline digestion | 40 min |
| filtration & washing | ~20 min) |
| Repeatability | ≤0.4% absolute error for samples with crude fiber <10% |
| Cooling Water Requirement | Inlet water temperature <20 °C |
| Compliance Basis | AOAC 962.09, ISO 5498:2022, GB/T 6434–2006 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SLQ-6 |
| Sample Capacity | 6 positions |
| Sample Mass Range | 0.5–3 g |
| Measurement Range | 0–100% (w/w) |
| Accuracy | Relative deviation ≤4%, Parallel deviation ≤0.4% |
| Total Cycle Time | ≤90 min (acid digestion: 30 min, alkaline digestion: 30 min, filtration & rinsing: ~30 min) |
| Heating System | Six independent semi-spherical ceramic heating elements with individual temperature control per crucible |
| Temperature Range | Ambient to 400 °C |
| Sealing Mechanism | Dual-layer PTFE isolation gasket (top and bottom) |
| Rated Power | 2 kW |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 570 × 470 × 750 mm |
| Weight | 30 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE ADVANCE |
| Application Standards | AOAC, AACC, ISO 6865, ISO 13906, ASTM D2974, EN ISO 12151 |
| Automation Level | Fully Automated Acid/Alkali Digestion, Filtration, Washing, and Residue Drying |
| Reagent Handling | Auto-dosing of H₂SO₄, NaOH, α-amylase, protease, ethanol, acetone, and antifoaming agent |
| Filtration System | Pressure-assisted vacuum filtration with programmable air-backflush |
| Control Interface | 7″ capacitive touchscreen (graphical UI, multilingual support) |
| Connectivity | Ethernet and Wi-Fi enabled for VELP Ermes Cloud Platform integration |
| Data Integrity | Audit trail, user access levels, electronic signatures compliant with FDA 21 CFR Part 11 requirements |
| Throughput | Up to 6 samples per run (batch mode), optional 24-position carousel for unattended operation |
| Safety Compliance | CE, UL/CSA certified, integrated fume extraction interface |
| Sample Capacity | 0.5–3.0 g (dry weight), compatible with standard Gooch crucibles or fiber bags (ANKOM-style) |
| Drying Module | Integrated infrared drying unit (60–150 °C, ±1 °C accuracy) |
| Waste Management | Dual-compartment acid/alkali waste collection with level sensors |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE ADVANCE |
| Sample Capacity | 6 positions |
| Throughput | up to 36 samples/day (Crude Fiber/Wende method), up to 60 samples/day (NDF/ADF/ADL) |
| Sample Mass | 0.5–3 g |
| Measurement Range | 0.1–100% fiber content |
| Repeatability | ±1% (at 5–30% fiber level) |
| Display | 7" color touchscreen |
| Reagent Delivery | Fully automated, pre-heated, precision dosing |
| Digestion Waste Handling | Integrated automatic collection |
| Safety | Closed-system reagent containment, no operator exposure to hot chemicals or fumes |
| Connectivity | LAN, USB (3×), Wi-Fi adapter optional |
| Power Supply | 230 V / 50–60 Hz |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 735 × 420 × 666 mm |
| Weight | 57 kg |
| Water Consumption | 1.0 L/min |
| Method Library | 5 pre-installed standard methods (ISO, AOAC, GB) + 30 customizable methods |
| Barcode Scanner Support | Yes |
| Balance Integration | Yes |
| Cloud Platform Compatibility | Via LAN or USB Wi-Fi adapter |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE |
| Sample Capacity | 6 positions (independent operation per sample) |
| Measurement Principle | Gravimetric difference method after sequential acid/alkali digestion (AOAC 978.10, ISO 5498, ISO 6865, EN ISO 13906) |
| Repeatability (RSD) | ±1% |
| Sample Mass Range | 0.5–3 g |
| Reagent Preheating Units | Dual independent RC2 heaters (RT to 370 °C) |
| Filtration & Backflush | Integrated air pump with three-way valve control |
| Waste Handling | Precision peristaltic pump for residue collection and effluent evacuation |
| Safety System | Self-diagnostic routine with audible/visual alarm timer |
| Construction | Stainless steel housing with chemical-resistant coating |
| Display | LCD interface with programmable time (0–99 min) and temperature settings |
| Power | 1200 W |
| Ambient Operating Temperature Control | Electronic PID regulation |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE6/3 |
| Sample Capacity | 6 positions per batch |
| Sample Mass Range | 0.5–3.0 g |
| Repeatability | ≤ ±1% |
| Measurement Range | 0–99% |
| Digestion Time | 0–100 min |
| Backflush Air Pressure | 3–8 bar |
| Backflush Pressure Accuracy | ≤ 1 bar |
| Preheating Unit Temperature Control | Ambient to 370 °C |
| Reagent Preheating | Dual independent 2-position heating zones |
| Fluid Handling | Integrated peristaltic pump for reagent drainage |
| Operation Mode | Single or sequential extraction (boiling, rinsing, filtration) under programmable control |
| Safety | Integrated alarm timer |
| Construction | Epoxy-coated steel frame for chemical and mechanical resistance |
| Valve System | Automated rotary valve for precise solvent routing |
| Fluid Separation | Dedicated inlets/outlets for reagents and cooling water |
| Sample Processing | In-situ digestion—no manual transfer required |
| Brand | Xianjian |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SLQ-200 |
| Pricing | Upon Request |
| Principle | Acid-Alkali Digestion (AOAC 962.09 / ISO 5498 / GB/T 6434) |
| Sample Capacity | 1–6 samples per run |
| Sample Mass Range | 0.5–3.0 g |
| Measurement Range | 0–100% crude fiber |
| Repeatability | ≤0.4% RSD |
| Total Cycle Time | ≤90 min |
| Heating Method | Semi-circular Silicon Carbide Heaters (Individually Controllable) |
| Temperature Control | Manual/Automatic Dual Mode, 0–200 °C |
| Heating Power Adjustment | Continuously Variable |
| Sealing System | Dual PTFE Isolation Gasket (Top & Bottom) |
| Liquid Delivery | Pressure-Driven Injection (vs. gravity-fed) |
| Reagent Preheating | Automatic Thermostatic Control with Over-Temperature Protection |
| Corrosion Resistance | Certified for H₂SO₄, NaOH, acetone, and other standard digestion solvents |
| Display | 4.3-inch HD Capacitive Touchscreen |
| Filtration System | High-Flow Vacuum Filtration with Chemically Resistant Components |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Rated Power | 1600 W (main unit), 1350 W (anti-dry-boil digestion vessel) |
| Dimensions (W×D×H) | 560 × 460 × 660 mm |
| Net Weight | 45 kg |
| Brand | Xianjian |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | SLQ-6A |
| Pricing | Available Upon Request |
| Measurement Principle | Acid-Alkali Sequential Digestion (AOAC 978.10 / ISO 5498 / GB/T 6434) |
| Sample Throughput | 1–6 samples per run |
| Sample Mass Range | 0.5–3.0 g |
| Measuring Range | 0.00–99.99% (dry basis) |
| Repeatability | ≤0.4% RSD |
| Total Cycle Time | ≤90 min |
| Heating System | Individual Semi-Circular Silicon Carbide Heaters (Independent Temperature Control per Vessel) |
| Sealing Mechanism | Dual PTFE Isolation Gasket (Top & Bottom) |
| Liquid Delivery | Pressurized Injection System |
| Reagent Preheating | Automatic PID-Controlled Constant-Temperature Heating with Over-Temperature Protection |
| Chemical Resistance | Full Compatibility with 1.25 M H₂SO₄, 1.25 M NaOH, Acetone, and Neutral Solvents |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Rated Power | 1600 W (Main Unit), 1350 W (Anti-Dry-Boil Digestion Module) |
| Dimensions (W×D×H) | 560 × 460 × 660 mm |
| Net Weight | 45 kg |
| Compliance | Designed to support AOAC Official Method 978.10, ISO 5498:2022, and GB/T 6434–2007 workflows |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-CXW |
| Price | USD 3,500 (FOB Qingdao) |