Empowering Scientific Discovery

Shanghai Xinxin Biotechnology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNAUER
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIJM SingleCore NanoProducer
Instrument TypeMicrofluidic Impingement Jet Homogenizer
Dimensions (W×D×H)900 × 915 × 700 mm
Max. Volumetric Flow Rate1 L/min (6 L/hr)
Max. Operating Pressure95 bar (1378 psi)
Solution Temperature Range4–60 °C
Inlet PortsFour 1/2″ TC fittings
Outlet PortOne 1/2″ TC fitting
Pump Count4
Flowmeter Count4
Valve Count1
Mixer Core Count1
SoftwareCDS (Compliant with 21 CFR Part 11 & GAMP5)
Construction MaterialStainless Steel 1.4301 (AISI 304)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNAUER
OriginGermany
ModelIJM NanoScaler
Instrument TypeMicrofluidic Impingement Jet Mixer
Dimensions (W×D×H)361 × 501 × 603 mm
Max. Flow Rate0.1 L/min
Max. Operating Pressure140 bar
Temperature Range4–60 °C
Inlet1/8″ OD, 2.1 mm ID FEP tubing (UNF 1/4-28, flat-bottom)
Outlet1/16″ OD, 0.5 mm ID PEEK tubing (UNF 10-32, conical thread)
Pump Count3
Flowmeter CountAs required
Valve Count2
Jet Mixer Modules1–5 interchangeable units
SoftwareCDS with optional 21 CFR Part 11 & GAMP5 compliance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNAUER
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCustomized NanoProducers
Instrument TypeMicrofluidic Impingement Jet Homogenizer
Dimensions (W×D×H)Configuration-Dependent
Max Number of IJM Mixers8
Max Number of Pumps16
Max Number of Coriolis Flowmeters16
Inlet Connections2 × Hygienic Clamp (DIN 11851 / ISO 2852)
Outlet Connection1 × Hygienic Clamp
Max Operating Pressure50–70 bar (725–1015 psi)
Flow Temperature Range4–60 °C
SoftwareKNAUER CDS (Compliant with FDA 21 CFR Part 11 & GAMP5)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNAUER
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIJM DuoCore NanoProducer
Instrument TypeMicrofluidic Impingement Jet Homogenizer
Dimensions (W×D×H)1000 × 1290 × 700 mm
Max. Volumetric Flow Rate2 L/min (120 L/hr)
Max. Operating Pressure95 bar (1378 psi)
Solution Temperature Range4–60 °C
Number of Impingement Mixers2
Number of High-Pressure Pumps8
Number of Coriolis Flowmeters8
Number of Valves2
Inlet Portssix 1/2″ TC fittings
Outlet Portstwo 1/2″ TC fittings
Cleaning SystemBack-flush integrated
Frame MaterialStainless Steel 1.4301 (AISI 304)
SoftwareCDS v5.x, compliant with FDA 21 CFR Part 11 and GAMP 5
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0