Empowering Scientific Discovery

Shanghai Yuanfangti Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVAT
OriginSwitzerland
Model54132-GE02
Component CategoryOptical Instrument Component
Sealing TechnologyFLEX VATRING “Hard-to-Hard” Metal Seal
Max Bakeout Temperature300 °C
Cycle Life (Clean Conditions)>1000 cycles
ActuationHex-key operated (no torque wrench required)
Vacuum CompatibilityUHV and XHV applications
MaterialStainless steel (seal ring and body)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVAT
OriginSwitzerland
Model01032-CE01
Leak Rate (Valve Body)<5×10⁻¹⁰ mbar·L/s
Leak Rate (Valve Seat)<1×10⁻⁹ mbar·L/s
Operating Pressure Range1×10⁻¹⁰ mbar to 2 bar (abs)
Max. Differential Pressure (Gate)≤2 bar
Max. Differential Pressure (at Opening)≤30 mbar
Service Life (Cycles to First Maintenance)50,000
Valve Body Temp. Limit≤250 °C (open), ≤200 °C (closed)
Actuator Temp. LimitsManual ≤250 °C, Pneumatic ≤200 °C, Solenoid ≤50 °C, Position Indicator ≤80 °C
Heating/Cooling Rate≤50 °C/h
Body MaterialAISI 304 (1.4301) or AISI 316L (1.4435)
Mechanism & Bellows MaterialAISI 304 / AISI 316L
SealMetal Bonnet, FKM (Viton®) Gate Seal
FeedthroughBellows-Sealed
MountingAny Orientation
Actuation Options24 V DC Solenoid (9.0 W single-acting with spring return
Position IndicationVisual mechanical indicator + electrical contacts (≤250 V AC / ≤50 V DC, ≤5 A / ≤3 A)
Nominal Diameter (DN)16, 25, 40, 50 mm
Molecular Conductance0.10–0.70 L/s (dependent on DN and flange type)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelYT890Z040
Pump TypeTurbo Molecular Pump
Oil-Free OperationYes
Pumping Speed (N₂)2200 L/s
Ultimate Pressure1×10⁻⁹ mbar
Weight38 kg
FlangeISO-F 250 / CF 250
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginUnited Kingdom
ModelTP-A
Pump TypeOil-Free Turbomolecular Pump System
Base Pressure≤5 × 10⁻¹⁰ mbar
Pumping Speed (N₂)84 L/s
Dimensions (W × D × H)376 × 279 × 239 mm
Weight17 kg
Drive Power300 W
Forevacuum RequirementIntegrated Diaphragm Pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelGRAPHIX
Channel Options1-channel, 2-channel, 3-channel
Pressure Range1×10⁻¹⁰ mbar to 2000 mbar
Sensor CompatibilityTHERMOVAC TTR, CERAVAC CTR, DU, PENNINGVAC PTR, IONIVAC ITR series active sensors
Operating PrincipleDigital signal processing of analog or digital outputs from active vacuum sensors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelIE 514
Measurement PrincipleCold Cathode Ionization
Pressure Range1 × 10⁻¹² to 1 × 10⁻⁴ mbar
Vacuum FlangeCF 40
ComplianceISO 3567, DIN 28403-1, EN 61000-6-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginUnited Kingdom
ModelRV3
Pump TypeOil-Sealed Rotary Vane Pump
Ultimate Vacuum2 × 10⁻³ mbar
Pumping Speed3.3 m³/h
Motor Power450 W
Dimensions (L×W×H)430 × 158 × 225 mm
Weight25 kg
Oil TypeUltragrade PFPE-based lubricant (compatible)
Voltage115/230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginCzech Republic
ModelnXDS10i
Pump TypeDry Scroll
Pumping Speed7–20 m³/h
Ultimate Pressure0.007 mbar
Dimensions (W×D×H)432 × 295 × 265 mm
Weight26 kg
Motor Power280 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelPTR 90
Measurement PrinciplePirani + Cold Cathode (Penning)
Range1×10³ to 1×10⁻⁸ mbar
Vacuum PortKF 25, CF 40
Output InterfaceRS232 / RS485 (digital), optional analog 0–10 V or 4–20 mA
Accuracy±30% (1×10⁻⁸–1×10⁻² mbar), ±15% (1×10⁻²–10 mbar)
LED IndicationAdaptive pulse-mode pressure display
HousingCompact stainless steel, IP65-rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelD8C
Pump TypeOil-Sealed Rotary Vane Pump
Ultimate Vacuum (with gas ballast closed)0.3 mbar
Pumping Speed (50 Hz)8.11 m³/h
Pumping Speed (60 Hz)9.65 m³/h
Inlet/Outlet PortDN25 KF
Noise Level (LpA)54–56 dB(A)
Motor Power550 W (Single-phase 220 V, 50 Hz or Three-phase 380 V, 50/60 Hz)
Oil TypeLeybold LVO 130
Oil Capacity1.5 L (max), 1.0 L (min)
Net Weight (dry)32 kg
Dimensions (W × D × H)260 × 173 × 272 mm
Operating Ambient Temperature10–40 °C
Maximum Allowable Water Vapor Pressure30 mbar
Gas Ballast Enabled Ultimate Pressure~6 × 10⁻² mbar
Gas Ballast Disabled Ultimate Pressure~3 × 10⁻² mbar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginGermany
ModelELD 500
Instrument TypePortable
Detection MethodVacuum Mode & Pressure Mode
Minimum Detectable Leak Rate1×10⁻¹² mbar·L/s (vacuum mode)
Startup Time≤120 s
Response Time<1 s
Maximum Inlet Pressure1500 Pa
Helium Purge Speed2.5 L/s
Leak Rate Display Range1×10⁻³ to 1×10⁻¹³ Pa·m³/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginUnited Kingdom
ModelTP-D
Pump TypeOil-Free Turbo Molecular Pump
Pumping Speed300–950 L/s
Ultimate Vacuum3 × 10⁻¹⁰ mbar
External Dimensions541 × 476 × 434 mm
Weight≤165 kg
Motor Power1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelDISPLAY
Channel Options1-Channel or 3-Channel
Pressure Range10⁻⁹ mbar to 2000 mbar
Compatible Sensor FamiliesTHERMOVAC TTR, DU, PENNINGVAC PTR
ComplianceCE, RoHS, EN 61000-6-2/-6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelHiPace 300
Nominal Pumping Speed for N₂260 L/s
Protection RatingIP54
CertificationsUL/CSA, CE, compliant with EN 61000-6-2/-4 and EN 61000-3-2
Integrated Drive ElectronicsTC 400
CoolingIntegrated water-cooling system
MountingFlange-compatible (DN 100 CF/KF optional)
Application ClassHigh and ultra-high vacuum (UHV) systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHiPace 80 Neo
Instrument TypeTurbomolecular Pump
Product TypeOil-Free Pump
Pumping Speed (N₂)67 L/s
Ultimate Pressure≤2.2 × 10⁻⁸ mbar (typical in high vacuum, corrected from erroneous “22 mbar” — consistent with HiPace 80 Neo datasheet)
External Dimensions (W × H × D)97 × 86 × 129 mm
Weight1.7 kg
Motor Power Supply110 V AC, 50/60 Hz (integrated drive electronics)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelTM 201
Measurement PrinciplePiezoresistive + Pirani
Range1200 to 5.0 × 10⁻⁵ mbar
Pressure InterfaceKF 16
Relative Pressure Capability–1060 to +1200 mbar
ComplianceCE, RoHS, ISO 9001 certified manufacturing environment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelOmniStar / ThermoStar
PrincipleQuadrupole Mass Filter
Response Time≤2 s
Mass Range Options1–100 amu, 1–200 amu, 1–300 amu
Inlet Capillary TemperatureUp to 350 °C
Inlet MaterialStainless Steel (OmniStar) or Fused Silica (ThermoStar)
Pumping SystemMVP dry diaphragm pump + HiPace turbomolecular pump
SoftwarePV MassSpec (qualitative & quantitative analysis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINFICON
OriginGermany
ModelCDG045D (1 Torr and 100 Torr full-scale options)
Vacuum FlangeKF 16
Measurement PrincipleCeramic Diaphragm Capacitance
Pressure Range5 × 10⁻² Torr to 1000 Torr (full-scale selectable: 1 Torr or 100 Torr)
Operating Temperature45 °C (thermally stabilized)
Output Signal0–10 V DC, gas-independent linear analog output
ComplianceCE, UL 61010-1, EN 61326-1, SEMI S2/S8, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS/Stanford Research Systems
OriginUSA
ModelRGA1-100amu, RGA1-200amu, RGA1-300amu
Mass Range1–100 amu / 1–200 amu / 1–300 amu
Resolution<0.5 amu (FWHM)
Detection Limit5 × 10⁻¹⁴ Torr (with EM detector)
Sensitivity2 × 10⁻⁴ A/Torr (Faraday cup)
Dynamic Range6 decades
Response Time1–2 s
Detector OptionsFaraday Cup (standard), Electron Multiplier (optional)
Operating Pressure Range10⁻⁴ Torr to UHV (FC)
Max. Probe Temperature70 °C
Max. Bakeout Temperature300 °C (probe only, ECU excluded)
InterfaceRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelTTR 101
Measurement PrincipleCombined Pirani + Capacitive Diaphragm
Range5×10⁻⁵ – 1500 mbar
Vacuum PortKF 16
ComplianceCE, RoHS, ISO 9001-manufactured design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelPKR 251
Measurement PrinciplePirani + Cold Cathode
Range5×10⁻⁹ to 1000 hPa
Vacuum InterfacesKF 25, CF 40, KF 40
Accuracy±30% (1×10⁻⁸ to 100 hPa)
Repeatability±5%
Operating Temperature5–55 °C
Bakeout Temperatureup to 150 °C
Power Supply15.0–30.0 V DC
Max. Power Consumption~2 W
Output Signal0–10.5 V analog voltage
Weight~700 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelHiCube 80 Eco
Pump TypeOil-Free Turbo-Molecular Pump System
Ultimate Pressure<1×10⁻⁸ Pa (without gas ballast)
Pumping Speed (N₂)67 L/s at DN 63 CF-F inlet
Pre-vacuum PumpMVP 015-2 multi-stage diaphragm pump
Forepump Speed1 m³/h (16.67 L/min, N₂)
Ultimate Forepressure<1×10⁻² Pa
CoolingConvection-cooled (standard)
Power Supply100–240 V AC, 50/60 Hz
Max. Power Consumption170 W
Sound Pressure Level≤50 dB(A)
Inlet FlangeDN 63 CF-F
Outlet FlangeG 1/8"
Dimensions (W×D×H)352 × 301 × 302 mm
Weight13.5 kg
ComplianceCE, RoHS, ISO 9001 certified
Control InterfaceIntegrated digital controller with status LEDs and RS-232/USB option
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeybold
OriginGermany
ModelPHOENIX Quadro
Instrument TypePortable
Detection MethodVacuum Mode
Minimum Detectable Leak Rate5 × 10⁻¹² mbar·L/s
Startup Time≤ 2 min
Response Time< 1 s
Maximum Inlet Pressure1500 Pa
Helium Purge Speed3.1 L/s
Leak Rate Display Range1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdwards Vacuum
OriginUnited Kingdom
ModelAPG 200
Measurement PrinciplePirani Thermal Conductivity
Pressure Range1 × 10⁻⁴ to 1 × 10⁴ mbar
Vacuum InterfaceKF 16 (ISO-KF)
ComplianceCE, RoHS, UKCA
Show next