- All
- Favorite
- Popular
- Most rated
| Brand | VAT |
|---|---|
| Origin | Switzerland |
| Model | 54132-GE02 |
| Component Category | Optical Instrument Component |
| Sealing Technology | FLEX VATRING “Hard-to-Hard” Metal Seal |
| Max Bakeout Temperature | 300 °C |
| Cycle Life (Clean Conditions) | >1000 cycles |
| Actuation | Hex-key operated (no torque wrench required) |
| Vacuum Compatibility | UHV and XHV applications |
| Material | Stainless steel (seal ring and body) |
| Brand | VAT |
|---|---|
| Origin | Switzerland |
| Model | 01032-CE01 |
| Leak Rate (Valve Body) | <5×10⁻¹⁰ mbar·L/s |
| Leak Rate (Valve Seat) | <1×10⁻⁹ mbar·L/s |
| Operating Pressure Range | 1×10⁻¹⁰ mbar to 2 bar (abs) |
| Max. Differential Pressure (Gate) | ≤2 bar |
| Max. Differential Pressure (at Opening) | ≤30 mbar |
| Service Life (Cycles to First Maintenance) | 50,000 |
| Valve Body Temp. Limit | ≤250 °C (open), ≤200 °C (closed) |
| Actuator Temp. Limits | Manual ≤250 °C, Pneumatic ≤200 °C, Solenoid ≤50 °C, Position Indicator ≤80 °C |
| Heating/Cooling Rate | ≤50 °C/h |
| Body Material | AISI 304 (1.4301) or AISI 316L (1.4435) |
| Mechanism & Bellows Material | AISI 304 / AISI 316L |
| Seal | Metal Bonnet, FKM (Viton®) Gate Seal |
| Feedthrough | Bellows-Sealed |
| Mounting | Any Orientation |
| Actuation Options | 24 V DC Solenoid (9.0 W single-acting with spring return |
| Position Indication | Visual mechanical indicator + electrical contacts (≤250 V AC / ≤50 V DC, ≤5 A / ≤3 A) |
| Nominal Diameter (DN) | 16, 25, 40, 50 mm |
| Molecular Conductance | 0.10–0.70 L/s (dependent on DN and flange type) |
| Brand | Edwards Vacuum |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YT890Z040 |
| Pump Type | Turbo Molecular Pump |
| Oil-Free Operation | Yes |
| Pumping Speed (N₂) | 2200 L/s |
| Ultimate Pressure | 1×10⁻⁹ mbar |
| Weight | 38 kg |
| Flange | ISO-F 250 / CF 250 |
| Brand | Edwards Vacuum |
|---|---|
| Origin | United Kingdom |
| Model | TP-A |
| Pump Type | Oil-Free Turbomolecular Pump System |
| Base Pressure | ≤5 × 10⁻¹⁰ mbar |
| Pumping Speed (N₂) | 84 L/s |
| Dimensions (W × D × H) | 376 × 279 × 239 mm |
| Weight | 17 kg |
| Drive Power | 300 W |
| Forevacuum Requirement | Integrated Diaphragm Pump |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | GRAPHIX |
| Channel Options | 1-channel, 2-channel, 3-channel |
| Pressure Range | 1×10⁻¹⁰ mbar to 2000 mbar |
| Sensor Compatibility | THERMOVAC TTR, CERAVAC CTR, DU, PENNINGVAC PTR, IONIVAC ITR series active sensors |
| Operating Principle | Digital signal processing of analog or digital outputs from active vacuum sensors |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | IE 514 |
| Measurement Principle | Cold Cathode Ionization |
| Pressure Range | 1 × 10⁻¹² to 1 × 10⁻⁴ mbar |
| Vacuum Flange | CF 40 |
| Compliance | ISO 3567, DIN 28403-1, EN 61000-6-3 |
| Brand | Edwards Vacuum |
|---|---|
| Origin | United Kingdom |
| Model | RV3 |
| Pump Type | Oil-Sealed Rotary Vane Pump |
| Ultimate Vacuum | 2 × 10⁻³ mbar |
| Pumping Speed | 3.3 m³/h |
| Motor Power | 450 W |
| Dimensions (L×W×H) | 430 × 158 × 225 mm |
| Weight | 25 kg |
| Oil Type | Ultragrade PFPE-based lubricant (compatible) |
| Voltage | 115/230 V, 50/60 Hz |
| Brand | Edwards Vacuum |
|---|---|
| Origin | Czech Republic |
| Model | nXDS10i |
| Pump Type | Dry Scroll |
| Pumping Speed | 7–20 m³/h |
| Ultimate Pressure | 0.007 mbar |
| Dimensions (W×D×H) | 432 × 295 × 265 mm |
| Weight | 26 kg |
| Motor Power | 280 W |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PTR 90 |
| Measurement Principle | Pirani + Cold Cathode (Penning) |
| Range | 1×10³ to 1×10⁻⁸ mbar |
| Vacuum Port | KF 25, CF 40 |
| Output Interface | RS232 / RS485 (digital), optional analog 0–10 V or 4–20 mA |
| Accuracy | ±30% (1×10⁻⁸–1×10⁻² mbar), ±15% (1×10⁻²–10 mbar) |
| LED Indication | Adaptive pulse-mode pressure display |
| Housing | Compact stainless steel, IP65-rated |
| Brand | Leybold |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D8C |
| Pump Type | Oil-Sealed Rotary Vane Pump |
| Ultimate Vacuum (with gas ballast closed) | 0.3 mbar |
| Pumping Speed (50 Hz) | 8.11 m³/h |
| Pumping Speed (60 Hz) | 9.65 m³/h |
| Inlet/Outlet Port | DN25 KF |
| Noise Level (LpA) | 54–56 dB(A) |
| Motor Power | 550 W (Single-phase 220 V, 50 Hz or Three-phase 380 V, 50/60 Hz) |
| Oil Type | Leybold LVO 130 |
| Oil Capacity | 1.5 L (max), 1.0 L (min) |
| Net Weight (dry) | 32 kg |
| Dimensions (W × D × H) | 260 × 173 × 272 mm |
| Operating Ambient Temperature | 10–40 °C |
| Maximum Allowable Water Vapor Pressure | 30 mbar |
| Gas Ballast Enabled Ultimate Pressure | ~6 × 10⁻² mbar |
| Gas Ballast Disabled Ultimate Pressure | ~3 × 10⁻² mbar |
| Brand | Edwards Vacuum |
|---|---|
| Origin | Germany |
| Model | ELD 500 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode & Pressure Mode |
| Minimum Detectable Leak Rate | 1×10⁻¹² mbar·L/s (vacuum mode) |
| Startup Time | ≤120 s |
| Response Time | <1 s |
| Maximum Inlet Pressure | 1500 Pa |
| Helium Purge Speed | 2.5 L/s |
| Leak Rate Display Range | 1×10⁻³ to 1×10⁻¹³ Pa·m³/s |
| Brand | Edwards Vacuum |
|---|---|
| Origin | United Kingdom |
| Model | TP-D |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Pumping Speed | 300–950 L/s |
| Ultimate Vacuum | 3 × 10⁻¹⁰ mbar |
| External Dimensions | 541 × 476 × 434 mm |
| Weight | ≤165 kg |
| Motor Power | 1000 W |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | DISPLAY |
| Channel Options | 1-Channel or 3-Channel |
| Pressure Range | 10⁻⁹ mbar to 2000 mbar |
| Compatible Sensor Families | THERMOVAC TTR, DU, PENNINGVAC PTR |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiPace 300 |
| Nominal Pumping Speed for N₂ | 260 L/s |
| Protection Rating | IP54 |
| Certifications | UL/CSA, CE, compliant with EN 61000-6-2/-4 and EN 61000-3-2 |
| Integrated Drive Electronics | TC 400 |
| Cooling | Integrated water-cooling system |
| Mounting | Flange-compatible (DN 100 CF/KF optional) |
| Application Class | High and ultra-high vacuum (UHV) systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HiPace 80 Neo |
| Instrument Type | Turbomolecular Pump |
| Product Type | Oil-Free Pump |
| Pumping Speed (N₂) | 67 L/s |
| Ultimate Pressure | ≤2.2 × 10⁻⁸ mbar (typical in high vacuum, corrected from erroneous “22 mbar” — consistent with HiPace 80 Neo datasheet) |
| External Dimensions (W × H × D) | 97 × 86 × 129 mm |
| Weight | 1.7 kg |
| Motor Power Supply | 110 V AC, 50/60 Hz (integrated drive electronics) |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TM 201 |
| Measurement Principle | Piezoresistive + Pirani |
| Range | 1200 to 5.0 × 10⁻⁵ mbar |
| Pressure Interface | KF 16 |
| Relative Pressure Capability | –1060 to +1200 mbar |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing environment |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar / ThermoStar |
| Principle | Quadrupole Mass Filter |
| Response Time | ≤2 s |
| Mass Range Options | 1–100 amu, 1–200 amu, 1–300 amu |
| Inlet Capillary Temperature | Up to 350 °C |
| Inlet Material | Stainless Steel (OmniStar) or Fused Silica (ThermoStar) |
| Pumping System | MVP dry diaphragm pump + HiPace turbomolecular pump |
| Software | PV MassSpec (qualitative & quantitative analysis) |
| Brand | INFICON |
|---|---|
| Origin | Germany |
| Model | CDG045D (1 Torr and 100 Torr full-scale options) |
| Vacuum Flange | KF 16 |
| Measurement Principle | Ceramic Diaphragm Capacitance |
| Pressure Range | 5 × 10⁻² Torr to 1000 Torr (full-scale selectable: 1 Torr or 100 Torr) |
| Operating Temperature | 45 °C (thermally stabilized) |
| Output Signal | 0–10 V DC, gas-independent linear analog output |
| Compliance | CE, UL 61010-1, EN 61326-1, SEMI S2/S8, RoHS |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | RGA1-100amu, RGA1-200amu, RGA1-300amu |
| Mass Range | 1–100 amu / 1–200 amu / 1–300 amu |
| Resolution | <0.5 amu (FWHM) |
| Detection Limit | 5 × 10⁻¹⁴ Torr (with EM detector) |
| Sensitivity | 2 × 10⁻⁴ A/Torr (Faraday cup) |
| Dynamic Range | 6 decades |
| Response Time | 1–2 s |
| Detector Options | Faraday Cup (standard), Electron Multiplier (optional) |
| Operating Pressure Range | 10⁻⁴ Torr to UHV (FC) |
| Max. Probe Temperature | 70 °C |
| Max. Bakeout Temperature | 300 °C (probe only, ECU excluded) |
| Interface | RS-232 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 101 |
| Measurement Principle | Combined Pirani + Capacitive Diaphragm |
| Range | 5×10⁻⁵ – 1500 mbar |
| Vacuum Port | KF 16 |
| Compliance | CE, RoHS, ISO 9001-manufactured design |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 251 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa |
| Vacuum Interfaces | KF 25, CF 40, KF 40 |
| Accuracy | ±30% (1×10⁻⁸ to 100 hPa) |
| Repeatability | ±5% |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | up to 150 °C |
| Power Supply | 15.0–30.0 V DC |
| Max. Power Consumption | ~2 W |
| Output Signal | 0–10.5 V analog voltage |
| Weight | ~700 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiCube 80 Eco |
| Pump Type | Oil-Free Turbo-Molecular Pump System |
| Ultimate Pressure | <1×10⁻⁸ Pa (without gas ballast) |
| Pumping Speed (N₂) | 67 L/s at DN 63 CF-F inlet |
| Pre-vacuum Pump | MVP 015-2 multi-stage diaphragm pump |
| Forepump Speed | 1 m³/h (16.67 L/min, N₂) |
| Ultimate Forepressure | <1×10⁻² Pa |
| Cooling | Convection-cooled (standard) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max. Power Consumption | 170 W |
| Sound Pressure Level | ≤50 dB(A) |
| Inlet Flange | DN 63 CF-F |
| Outlet Flange | G 1/8" |
| Dimensions (W×D×H) | 352 × 301 × 302 mm |
| Weight | 13.5 kg |
| Compliance | CE, RoHS, ISO 9001 certified |
| Control Interface | Integrated digital controller with status LEDs and RS-232/USB option |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PHOENIX Quadro |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s |
| Startup Time | ≤ 2 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 1500 Pa |
| Helium Purge Speed | 3.1 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Edwards Vacuum |
|---|---|
| Origin | United Kingdom |
| Model | APG 200 |
| Measurement Principle | Pirani Thermal Conductivity |
| Pressure Range | 1 × 10⁻⁴ to 1 × 10⁴ mbar |
| Vacuum Interface | KF 16 (ISO-KF) |
| Compliance | CE, RoHS, UKCA |