| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| Temperature Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| CO₂ Control Range & Accuracy | 0–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–95%, ±0.2% |
| Humidity Control | ≥90% RH (natural evaporation, unregulated) |
| Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 550 W |
| Internal Chamber Dimensions | 500 × 500 × 650 mm |
| Standard Accessories | 2 adjustable stainless-steel shelves, HEPA filter, UV sterilization lamp, removable water pan |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95%, ±0.2% |
| CO₂ Range | 0–20%, ±0.1% |
| Temperature Range | RT+5°C to 60°C, ±0.1°C control resolution, ±0.2°C stability |
| Humidity | Natural evaporation via removable water pan, ≥90% RH (unregulated) |
| Capacity | 50 L |
| External Dimensions | 345 × 355 × 410 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 350 W |
| Internal Chamber Material | Electropolished stainless steel (304), electrochemically passivated |
| Filtration | Integrated HEPA filter (H14 class, ≥99.995% @ 0.3 µm) with real-time filter life monitoring |
| Sterilization | Built-in UV-C lamp (254 nm), programmable cycle, full-chamber irradiation including fan blades, sensor surfaces, and humidification pan |
| Gas Control Logic | Adaptive N₂ balancing algorithm ensuring CO₂ + O₂ + N₂ = 100% |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Air-Jacketed Tri-Gas Incubator |
| Model | TGC-80 |
| Temperature Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| CO₂ Control Range & Accuracy | 0–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–95%, ±0.2% |
| Humidity | ≥90% RH (natural evaporation, unregulated) |
| Capacity | 80 L |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 400 W |
| Filtration | Integrated HEPA filter |
| Sterilization | UV lamp system |
| Gas Sensors | IR-based CO₂ sensor |
| Heating | Six-sided air-jacketed heating with door heating |
| Air Circulation | Low-turbulence micro-circulation fan system |
| Safety | Dual-door structure with heated inner glass, multi-level alarm logic (temperature deviation, gas concentration drift, door-open duration, sensor fault) |