BrandPOWEREACH
OriginShanghai, China
ModelJMD04A
Instrument TypeElectromechanical Burst Tester
Maximum Burst Force50 kgf (490.3 N)
Displacement Resolution0.01 mm
ComplianceASTM D3786, ISO 13938-1, GB/T 7742.1, BS EN ISO 13938-1
SoftwareWindows-based control & analysis suite with real-time force-displacement curve acquisition, auto peak detection, statistical reporting (mean, SD, CV%), and export to CSV/PDF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJMD04C
Maximum Burst Force5000 kgf (49.05 kN)
Test Speed RangeAdjustable
Stroke RangeAdjustable
Displacement ResolutionNot specified
Instrument TypeElectromechanical Burst Testing Machine
ComplianceDesigned for ASTM D3787, ISO 13938-1, GB/T 7742.1, and related textile & membrane burst standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJS94H-3H10X
Zeta Potential Range±200 mV (typical, dependent on sample conductivity)
pH Range1.6–13.0 (optimal 2.0–12.0)
Operating Temperature20–35 °C
Temperature Resolution0.1 °C
Optical Resolution3 pixels/µm
System Accuracy±5% relative error (per GB/T 32668-2016 validation protocol)
Particle Size Applicability0.5–20 µm (aqueous dispersions)
Power Consumption<150 W
Input Voltage220 V AC, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99D1
Measurement Range0–500 mN/m
Resolution0.01 mN/m
Accuracy±0.01 mN/m
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Temperature Sensing Accuracy±0.1 °C
Power SupplyAC 220 ±5 V, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJS94K-3H20X
Zeta Potential Range±200 mV (typical, inferred per ISO 13099-2)
pH Range1.6–13.0 (standard operation 2.0–12.0, resolution 0.1)
Temperature RangeAmbient to 35 °C (measurement resolution 0.1 °C)
Particle Size Compatibility0.2–50 µm (aqueous dispersions)
Optical Resolution1.93–12 pixels/µm (motorized zoom optical system)
Power Consumption<150 W
ComplianceGB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJS94J-1K20X
Zeta Potential Range±200 mV (typical, dependent on sample conductivity)
pH Range1.6–13.0 (optimal 2.0–12.0)
Operating Temperature20–35 °C
Temperature Resolution0.1 °C
Optical Resolution12 pixel/μm
System Accuracy≤5% systematic error
Particle Size Applicability0.1–10 μm (aqueous dispersions)
Power Consumption<150 W
Input Voltage220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJC2000C1
Instrument TypeBenchtop Laboratory Goniometer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Contact Angle Accuracy±0.1° or ±0.5° (selectable via tangent method)
Sample Stage Dimensions70 mm × 100 mm (fixed)
Maximum Sample Size (L×W×H)≤100 mm × ∞ × 25 mm
Maximum Sample Thickness25 mm
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Pendant Drop Method)0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Measurement ModesStatic contact angle, advancing/receding angle (via syringe infusion/withdrawal), dynamic contact angle, sessile drop, pendant drop, captive bubble
Software Analysis MethodsTangent (3-/4-/5-point), circle/ellipse fitting, Young–Laplace curve fitting, Owens–Wendt two-liquid surface energy model
Imaging Capture ModesSingle-frame freeze, time-lapse (1–3600 s interval), high-speed video (30 fps)
Mechanical Adjustments4-axis manual stage (X/Y/Z + tilt)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJJ2000B2
Measurement Range (Interfacial Tension)1×10⁻⁶ mN/m to 100 mN/m
Resolution0.001 mN/m
Accuracy<2% (100 mN/m to 10⁻² mN/m), <8% (10⁻³ mN/m to 10⁻⁶ mN/m)
Rotational Speed Range2000–10,000 rpm
Speed Stability±0.1%
Temperature Control RangeAmbient to 95 °C
Capillary Inner Diameter2 mm / 4 mm
Contact Angle Range0–180°
Contact Angle Resolution0.01°
Image Magnification50–318 px/mm
Frame RateUp to 30 fps (continuous), programmable interval capture (1–3600 s)
Power Consumption<50 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJJ2000H2
Measurement Range100 to 1×10⁻⁶ mN/m
Resolution0.001 mN/m
Accuracy±0.01 mN/m
Measurement PrincipleImage-based spinning drop analysis — high-speed CCD captures droplet morphology under controlled centrifugal rotation
Temperature Control RangeAmbient to 150 °C
Pressure Rating0.7 MPa
Maximum Rotational Speed14,000 rpm
Speed Control Precision±5 rpm
Heating SystemPID-controlled stainless-steel jacketed heater with Pt100 sensor
Imaging System60 fps monochrome CCD (752 × 480 pixels), motorized XYZ-stage with 0.01 mm resolution, 0.7–4.5× zoom lens
Sample Tube Optionsφ2 mm and φ4 mm quartz capillaries
InterfaceUSB 2.0 or RS232
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
Instrument TypeElectronic Burst Testing Machine
Maximum Burst Force1000 kgf (9.8 kN)
Displacement Resolution≤ 0.01 mm
Load Cell AccuracyClass 0.5 per ISO 7500-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
Instrument TypePortable Rotational Viscometer
Viscosity Range1–1,000,000 mPa·s
Rotational Speeds7.5 / 75 / 750 rpm
Accuracy±4% (for Newtonian fluids)
Dimensions (L×W×H)170 × 140 × 440 mm
Weight14 kg
Power SupplyAC 220 V ±10%, 50 Hz ±10%
ComplianceDesigned for routine QC and R&D in industrial and academic labs per ISO 2555 and ASTM D2196 principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99B
Measurement Range0–500 mN/m
Resolution0.01 mN/m
Accuracy±0.05 mN/m
Temperature Display Accuracy±0.1 °C
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Power SupplyAC 220 V ±5%, <150 W
InterfaceRS-232 Serial (requires external PC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJJ2000H
Measurement Range100 to 10⁻⁶ mN/m
Resolution0.001 mN/m
Accuracy±0.01 mN/m
Temperature Control RangeAmbient to 150 °C
Max Operating Pressure0.7 MPa
Motor Speed Range1,000–14,000 rpm
Speed Control Precision±5 rpm
Heating MethodElectric, Pt100 Sensor
Imaging752×480 CCD, 60 fps, LED-illuminated
Sample Tube IDφ2 mm and φ4 mm quartz
InterfaceRS232 or USB 2.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJC2000D1
Instrument TypeBenchtop Laboratory System
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Sample Stage Dimensions70 × 100 mm (expandable)
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Pendant Drop Method)0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Maximum Sample Size70 mm × 100 mm × 25 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
ModelJB04
OriginShanghai, China
Light Source532 nm green laser (20 mW or 50 mW)
Laser Intensity Adjustment1–100% continuous
Objective LensJapanese MS-01 zoom objective, working distance 90 mm, magnification 700–1100 px/mm
Spatial Resolution2 µm
Incident Angle Range45°–60°
Polarization SystemHigh-grade optical prism polarizer
Imaging SensorHigh-sensitivity CCD with electronic shutter
Image AcquisitionCG400 frame grabber card
Operating System CompatibilityWindows XP (32-bit), Windows 7 (32-bit)
InterfaceRS232 serial port, native PCI slot required
SoftwareProprietary GUI-based acquisition and analysis software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJDF05
Instrument TypeCoefficient of Friction Tester
Max. Friction ForceNot Specified
Friction Force ResolutionmN
ComplianceASTM D1894, ISO 8295, GB/T 10006
Software InterfaceUSB + RS232 (COM port required)
Data AcquisitionReal-time force-time curve, static/dynamic COF calculation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJS94J2-1K20X
Zeta Potential Range±200 mV (typical, per GB/T 32668-2016 calibration protocol)
pH Range1.6–13.0 (standard operation: 2.0–12.0)
Operating Temperature20–35 °C
Temperature Resolution0.1 °C
Optical Resolution12 pixel/μm
Microscope SystemWDK Japan high-magnification optical module, working distance 7 mm
System Accuracy≤5% relative error (per ISO 13099-2:2012 validation methodology)
Particle Size Applicability0.1–10 μm (aqueous & organic dispersions)
Power Consumption<150 W, 220 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelNDJ-4
Instrument TypePortable Rotational Viscometer
Viscosity Range1–2,000,000 mPa·s
Speed Settings0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm
Accuracy±5% (for Newtonian fluids)
Power Supply220 V ±10%, 50 Hz
Net Weight1.5 kg
Dimensions320 × 260 × 170 mm
Included Rotors#1, #2, #3, #4
ComplianceDesigned for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJC2000E
Instrument TypeBenchtop Laboratory Goniometer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Accuracy±0.1°
Sample Stage Dimensions100 mm × 100 mm
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Sessile Drop & Pendant Drop Methods)0.01–2000 mN/m
Optical System0.7–4.5× Continuous Zoom Lens with Post-Magnification Optics
Camera InterfaceUSB 3.0 Digital CCD
SoftwarePOWEREACH® V2.11 Image Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99F2
Measurement Range0–999.99 mN/m
Resolution0.01 mN/m
Accuracy±0.1 mN/m
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Temperature Sensing Accuracy±0.1 °C
Power SupplyAC 220 V ±5%, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99F
Measurement Range0–999.99 mN/m
Resolution0.01 mN/m
Accuracy±0.01 mN/m
MethodsDu Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume)
Sampling Cycle1–5 s (plate), 50–200 s (ring)
Z-axis Travel0–30 mm
Z-axis Precision1 µm
Power SupplyAC 220 ±5 V, <150 W
Operating Humidity30–85% RH
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
Instrument TypeBenchtop Rotational Viscometer
Viscosity Range1–2,000,000 mPa·s
Spindle SetStandard #1–#4 spindles (optional #0 spindle for down to 0.1 mPa·s)
Speed Settings0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm
Accuracy±2% for Newtonian fluids
DisplayBacklit LCD with real-time spindle/speed/viscosity/% full-scale readout
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Operating Environment5–35 °C, ≤80% RH
Dimensions370 × 325 × 280 mm
Net Weight6.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJDS05C
Instrument TypeElectromechanical Triaxial Testing System
Max Biaxial Tensile Force4.0–5.0 kN (per axis)
Max Punching Force (Z-axis)2.0 kN
Displacement Resolution0.02 mm
Crosshead Speed Range0.8–2.0 mm/s
Max Travel per Axis300 mm
Load Cell Accuracy±1 N (with overload protection)
High-Speed Imaging30–200 fps CCD camera
Operating Environment8–30 °C, RH < 80%
Software ControlReal-time speed, stroke, and data acquisition via proprietary Windows-based interface
ComplianceConfigurable to ASTM D5034, D5035, D638, ISO 13934-1, ISO 13935-1, GB/T 3923.1, and textile-specific GLP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJN01A
Zeta Potential Measurement PrincipleMass-Exchange Electrophoresis
Sample Concentration RangeHigh-concentration dispersions (undiluted, slurry-state)
pH RangeNot specified
ComplianceDesigned for ASTM D4187, ISO 13099-2, and GLP-compliant workflows requiring raw-state dispersion analysis
InterfaceRS232 (COM port) + USB
SoftwareJN01.exe (Windows XP / 32-bit Windows 7 compatible)