BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99D1
Measurement Range0–500 mN/m
Resolution0.01 mN/m
Accuracy±0.01 mN/m
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Temperature Sensing Accuracy±0.1 °C
Power SupplyAC 220 ±5 V, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJC2000C1
Instrument TypeBenchtop Laboratory Goniometer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Contact Angle Accuracy±0.1° or ±0.5° (selectable via tangent method)
Sample Stage Dimensions70 mm × 100 mm (fixed)
Maximum Sample Size (L×W×H)≤100 mm × ∞ × 25 mm
Maximum Sample Thickness25 mm
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Pendant Drop Method)0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Measurement ModesStatic contact angle, advancing/receding angle (via syringe infusion/withdrawal), dynamic contact angle, sessile drop, pendant drop, captive bubble
Software Analysis MethodsTangent (3-/4-/5-point), circle/ellipse fitting, Young–Laplace curve fitting, Owens–Wendt two-liquid surface energy model
Imaging Capture ModesSingle-frame freeze, time-lapse (1–3600 s interval), high-speed video (30 fps)
Mechanical Adjustments4-axis manual stage (X/Y/Z + tilt)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJJ2000B2
Measurement Range (Interfacial Tension)1×10⁻⁶ mN/m to 100 mN/m
Resolution0.001 mN/m
Accuracy<2% (100 mN/m to 10⁻² mN/m), <8% (10⁻³ mN/m to 10⁻⁶ mN/m)
Rotational Speed Range2000–10,000 rpm
Speed Stability±0.1%
Temperature Control RangeAmbient to 95 °C
Capillary Inner Diameter2 mm / 4 mm
Contact Angle Range0–180°
Contact Angle Resolution0.01°
Image Magnification50–318 px/mm
Frame RateUp to 30 fps (continuous), programmable interval capture (1–3600 s)
Power Consumption<50 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJJ2000H2
Measurement Range100 to 1×10⁻⁶ mN/m
Resolution0.001 mN/m
Accuracy±0.01 mN/m
Measurement PrincipleImage-based spinning drop analysis — high-speed CCD captures droplet morphology under controlled centrifugal rotation
Temperature Control RangeAmbient to 150 °C
Pressure Rating0.7 MPa
Maximum Rotational Speed14,000 rpm
Speed Control Precision±5 rpm
Heating SystemPID-controlled stainless-steel jacketed heater with Pt100 sensor
Imaging System60 fps monochrome CCD (752 × 480 pixels), motorized XYZ-stage with 0.01 mm resolution, 0.7–4.5× zoom lens
Sample Tube Optionsφ2 mm and φ4 mm quartz capillaries
InterfaceUSB 2.0 or RS232
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99B
Measurement Range0–500 mN/m
Resolution0.01 mN/m
Accuracy±0.05 mN/m
Temperature Display Accuracy±0.1 °C
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Power SupplyAC 220 V ±5%, <150 W
InterfaceRS-232 Serial (requires external PC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJJ2000H
Measurement Range100 to 10⁻⁶ mN/m
Resolution0.001 mN/m
Accuracy±0.01 mN/m
Temperature Control RangeAmbient to 150 °C
Max Operating Pressure0.7 MPa
Motor Speed Range1,000–14,000 rpm
Speed Control Precision±5 rpm
Heating MethodElectric, Pt100 Sensor
Imaging752×480 CCD, 60 fps, LED-illuminated
Sample Tube IDφ2 mm and φ4 mm quartz
InterfaceRS232 or USB 2.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJC2000D1
Instrument TypeBenchtop Laboratory System
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Sample Stage Dimensions70 × 100 mm (expandable)
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Pendant Drop Method)0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Maximum Sample Size70 mm × 100 mm × 25 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
ModelJB04
OriginShanghai, China
Light Source532 nm green laser (20 mW or 50 mW)
Laser Intensity Adjustment1–100% continuous
Objective LensJapanese MS-01 zoom objective, working distance 90 mm, magnification 700–1100 px/mm
Spatial Resolution2 µm
Incident Angle Range45°–60°
Polarization SystemHigh-grade optical prism polarizer
Imaging SensorHigh-sensitivity CCD with electronic shutter
Image AcquisitionCG400 frame grabber card
Operating System CompatibilityWindows XP (32-bit), Windows 7 (32-bit)
InterfaceRS232 serial port, native PCI slot required
SoftwareProprietary GUI-based acquisition and analysis software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJC2000E
Instrument TypeBenchtop Laboratory Goniometer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Accuracy±0.1°
Sample Stage Dimensions100 mm × 100 mm
Image Magnification50–318 pixels/mm
Surface/Interfacial Tension Range (Sessile Drop & Pendant Drop Methods)0.01–2000 mN/m
Optical System0.7–4.5× Continuous Zoom Lens with Post-Magnification Optics
Camera InterfaceUSB 3.0 Digital CCD
SoftwarePOWEREACH® V2.11 Image Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99F2
Measurement Range0–999.99 mN/m
Resolution0.01 mN/m
Accuracy±0.1 mN/m
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Temperature Sensing Accuracy±0.1 °C
Power SupplyAC 220 V ±5%, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99F
Measurement Range0–999.99 mN/m
Resolution0.01 mN/m
Accuracy±0.01 mN/m
MethodsDu Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume)
Sampling Cycle1–5 s (plate), 50–200 s (ring)
Z-axis Travel0–30 mm
Z-axis Precision1 µm
Power SupplyAC 220 ±5 V, <150 W
Operating Humidity30–85% RH
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJML04C2
Surface Tension Range0–150 mN/m
Resolution< 0.05 mN/m
Measurement MethodWilhelmy Plate
Trough MaterialPTFE
Trough Dimensions300 mm × 100 mm
Compression RatioUp to 90%
Barrier Speed0.05–3 mm/s
Vertical Deposition Speed0.02–2 mm/s
Operating TemperatureAmbient (with optional external thermostatic bath, ≤65 °C)
Power SupplyAC 220 V ±10%, 50 Hz, <150 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJJ2000B
Measurement Range10⁻⁶ mN/m to 100 mN/m
Resolution0.001 mN/m
Accuracy<2% from 100 mN/m to 10⁻² mN/m
Rotational Speed Range2000–10,000 rpm
Speed Stability±0.1%
Capillary Inner Diameter2 mm / 4 mm
Temperature Control RangeAmbient to 95 °C
CameraUSB 2.0 industrial digital camera, 60 fps
Light Source12 V flat-panel lamp (70 × 19 mm)
Magnification Options1× and 2× T-shaped optical heads
Power Consumption<50 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJK99 Series
Measurement Range0–500 mN/m (JK99F & JK99M: 0–1000 mN/m)
Resolution0.01 mN/m
Accuracy±0.01 mN/m
Measurement MethodsDu Noüy Ring Method & Wilhelmy Plate Method
Sensor TypeImported Japanese load cell (JK99B/C/D), METTLER high-precision balance sensor (JK99M)
Temperature Sensing Accuracy±0.1 °C
Power SupplyAC 220 V ±5 V, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelTX-500C
Measurement Range10⁻⁶–100 mN/m
Temperature Control RangeRT+5 °C to 95 °C
Temperature Display Range0–99.9 °C
Temperature Accuracy±0.1 °C
Image CaptureUSB Digital CCD (60 fps, 752×480 px)
Rotation Speed1,000–10,000 rpm (±5 rpm control accuracy)
Spatial Resolution0.001 mm
Optical Readout Field0–6 mm
InterfaceUSB & RS-232
Heating SystemPID-Controlled Stainless Steel Electric Heater
Sample Tube OptionsHigh-Purity Quartz Tubes (ID: 2 mm, 4 mm, 6 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandPOWEREACH
OriginShanghai, China
ModelJF99A
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleWashburn Capillary Penetration Method
Contact Angle Range0–90° (calculated, relative)
Contact Angle Resolution±0.3°
Pressure Measurement Range0–330 mbar
Pressure Accuracy±0.16 mbar
Quartz Tube DimensionsOD 10 mm / ID 8 mm or ID 6 mm
Sample Particle Size Requirement≤200 mesh (74 µm)
Surface Tension Range0.01–2000 mN/m
Image Magnification0.7×–5× (50–318 pixel/mm)
Stage Size120 × 120 mm
Power Consumption<20 W
Dimensions (W×D×H)295 × 240 × 260 mm]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJC2000P
Instrument TypePortable Video Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Image Resolution1280×1024 pixels
Frame Rate30 fps
Light SourceUniform High-Brightness LED with IR Filtering
Camera1.3-Megapixel USB 2.0 CCD with Real-Time Capture
Power SupplyUSB 2.0 Bus-Powered or External AC 220 V / 50 Hz
Dimensions (W×D×H)240 × 200 × 300 mm (incl. handle)
Weight4 kg (incl. liquid reservoir)
Analysis Methodsθ/2 Method, Height Method (3-Point Planar / 4-Point Curved), 5-Point Curve Fitting (Advancing/Receding), Tangent Method
Measurement ModesStatic Contact Angle (Left/Right/Average), Dynamic Contact Angle, Droplet Volume & Diameter Quantification
Image FormatBMP
Video FormatAVI
SoftwareProprietary Image Analysis Suite with Automated Edge Detection and Geometric Fitting Algorithms
ComplianceDesigned for GLP-supporting workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen)
OriginShanghai, China
ModelJK99C
Measurement Range0–500 mN/m
Resolution0.01 mN/m
Accuracy±0.05 mN/m
MethodsPlatinum Ring Method (Du Noüy) & Platinum Plate Method (Wilhelmy Plate)
Temperature Sensing Precision±0.1 °C
Power SupplyAC 220 V ±5%, <150 W
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJJ2000D1
Measurement Range10⁻⁶–100 mN/m
Temperature Control Range5–95 °C (PID electric heating or external water bath)
Temperature Display Accuracy±0.1 °C
Rotational Speed1,000–10,000 rpm (±5 rpm control accuracy)
ImagingUSB-triggered CCD, 60 fps (optional 120 fps)
Spatial Resolution0.001 mm
Sample Tube ID2 mm & 4 mm high-purity quartz
Data OutputExcel-compatible database with time-, speed-, and temperature-stamped records
ComplianceDesigned for GLP-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJMP2000A
Surface Tension Range0–150 mN/m
Resolution< 0.05 mN/m
Measurement MethodWilhelmy Plate
Langmuir Trough Dimensions (Upper Chamber)70 mm × 150 mm × 8 mm (W × L × H)
Max Measurable Area96.6 cm²
Min Measurable Area19.32 cm²
Oscillation Frequency Range (Sinusoidal Mode)0.001–1 Hz
Area Strain Amplitude1–6% (relative to equilibrium area)
Relaxation Step Change5–30% area change in 1–2 s
Sampling Interval150–300 s
Power SupplyAC 220 V ±10%, 50 Hz
Max Power Consumption<150 W
Operating TemperatureAmbient
Operating Humidity30–85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJC2000X1
Instrument TypeBenchtop Dynamic Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.05°
Sample Stage Dimensions400 × 400 mm (Aerospace-Grade Aluminum)
Optical Magnification50–318 pixels/mm (0.7×–5× zoom)
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJC2000Y Series
Sample StageCircular, φ50–φ81 mm diameter, 5–30 mm thickness
Application FocusContact angle measurement on convex spherical lenses (glass & optical resin)
ComplianceDesigned for ISO 19403-2, ASTM D7334, and GB/T 24368-2009 surface wettability testing protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.)
OriginShanghai, China
ModelJC2000C1
Instrument TypeBenchtop Laboratory Contact Angle Measurement System
Measurement ModesStatic & Dynamic Contact Angle, Surface/Interfacial Tension (Sessile Drop & Pendant Drop), Surface Free Energy (Owens-Wendt Method)
Angular Range0–180°
Angular Resolution0.1° or 0.5° (selectable)
Image Magnification50–318 pixels/mm
Sample Stage Dimensions100 × 100 mm²
Vertical Stage Travel20 mm
Manual X/Y Stage Travel60 mm (X), 50 mm (Y)
Lens Translation Range40 mm (Z)
ImagingUSB Digital CCD Camera, 25 fps Real-Time Capture
SoftwareProprietary Image Analysis Suite with Automated Tangent Fitting, Spline Curve Fitting (5-Point), Height-Method Calculation (3-/4-Point), and CMC/Surface Energy Modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPOWEREACH
OriginShanghai, China
ModelJK99M1
Measurement Range0–999.999 mN/m
Resolution0.001 mN/m
Accuracy±0.01 mN/m
MethodsDu Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume)
Sampling Interval1–5 s (Plate), 50–200 s (Ring)
ComplianceGB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999
SensorHigh-precision 0.1 mg electromagnetic balance (METTLER-origin system)
Data Acquisition Rate10 Hz (standard), 50 Hz (optional)
Temperature Sensing Accuracy±0.1 °C
Platform Vertical Travel0–30 mm (standard), up to 100 mm (optional)
Positional Repeatability±0.1 mm (±1 µm with optional sensor)
Power SupplyAC 220 V ±5%, <150 W
Operating Humidity30–85% RH