- All
- Favorite
- Popular
- Most rated
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Model | BP-105D-X-SUS |
| Body Material | SUS316 & PTFE (Teflon) |
| Actuation | 5-Port Pneumatic |
| Operating Pressure | 0.4–0.5 MPa (4–5 kgf/cm²) |
| Max Inlet Pressure | 0.5 MPa |
| Minimum Dispense Volume | 0.01 mL |
| Kv Value | 3.42 L/min |
| Weight | ~420 g |
| Fluid Compatibility | Low-to-medium viscosity liquids, solvents, aqueous solutions, silicones, epoxies, RTV rubbers, pharmaceutical excipients |
| Wetted Parts | SUS316 stainless steel + PTFE diaphragm & seals |
| Maintenance Design | Bag-Nut assembly for tool-free diaphragm replacement |
| Mounting | 360° rotatable body with adjustable tubing orientation |
| Brand | AEMIC |
|---|---|
| Model | AE-1136D |
| Origin | Japan |
| Measurement Principle | Ratio-based comparative resistance measurement against external reference thermistor |
| Temperature Compensation | Automatic thermoelectric EMF cancellation |
| Measurement Speed | Ultra-high-speed (7-class sorting capability) |
| Output | Percentage deviation from reference standard (%) |
| Compliance | Designed for industrial QC environments |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | ADVANTEC (TAMASAKI, Kyoto, Japan) |
|---|---|
| Origin | Japan |
| Model | CCP-10-E1D |
| Nominal Pore Size | 10 µm |
| Effective Filtration Area | 550 cm² |
| Max Operating Pressure | 0.39 MPa @ 25°C |
| Max Operating Temperature | 60°C |
| Construction Material | Polypropylene (Melt-Blown) |
| Dimensions | Ø77 mm × 102 mm (L) |
| Inlet/Outlet | 1/4" NPT Male |
| Packaging | 85 × 85 × 130 mm, 180 g |
| Brand | AEMIC |
|---|---|
| Origin | Japan |
| Model | AE-1152D |
| Measurement Principle | 4-Terminal Kelvin (DC) |
| Basic Accuracy | ±(0.01% rdg + 1 μΩ) on 1 mΩ range |
| Minimum Resolution | 10 nΩ |
| Measurement Ranges | 0.0000 mΩ to 1.5000 kΩ |
| Test Currents | 3 A (1 mΩ), 1 A (10 mΩ), 100 mA (100 mΩ–10 Ω), 10 mA (100 Ω–1 kΩ), 1 mA (1 kΩ) |
| Open-Circuit Voltage | ≤5 V |
| Sampling Rate | 2–10 Hz (free-run) |
| Interfaces | Standard GPIB/RS-232C/Centronics (one optional interface built-in) |
| Comparator Outputs | Open-collector (max 40 V, 100 mA) for LO/GO/HI, CONT-E, EOC |
| Operating Environment | 5–40°C, ≤85% RH |
| Power Supply | AC 85–265 V, 50–60 Hz, ~60 VA |
| Dimensions | 333 W × 99 H × 300 D mm (excl. protrusions) |
| Weight | ~3 kg |
| Compliance | CE-marked |
| Brand | ADCMT (formerly Advantest) |
|---|---|
| Model | 8230E |
| Sensor | 82313B |
| Measurement Range | Up to 200 mW |
| Wavelength Calibration | 650 nm / 780 nm (CD/DVD standard) |
| Resolution | 0.01 dB (4½-digit) |
| Interface | Standard USB |
| Sensor Form Factor | Cylindrical |
| Compliance | Designed for CD/DVD manufacturing line testing |
| Origin | Japan |
| Sensor Stability | Optimized for long-term stability in 400 nm band |
| Wavelength Correction | 1 nm step sensitivity correction (optional for select sensors) |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPC-201N12 |
| Drive Method | Manual |
| Measurement Range | ±200.0 Pa |
| Display Resolution | 0.1 Pa |
| Accuracy | ±0.1% FS ±1 digit |
| Temperature Drift | ±0.12% FS/°C |
| Display Update Interval | 0.1 s |
| Analog Output | 1–5 V (fully scalable) |
| Warm-up Time | 10 min |
| Sensor Type | Silicon Diaphragm |
| Compatible Media | Non-corrosive and mildly corrosive gases |
| Overpressure Limit | 10 kPa |
| Static Pressure Range | 30 kPa |
| Operating Ambient Temperature | 0–45°C (40°C max with AC adapter) |
| Dimensions | 96 × 96 × 141 mm (W × H × D) |
| Weight | 0.9 kg (excl. AC adapter) |
| Pressure Port | Φ8 mm hose barb (convertible to PT1/4 internal thread) |
| Power Supply | DC 12 V ±10% via included AC adapter (AC 100 V input, 10 W consumption) |
| Standard Functions | Hi/Go/Lo contact outputs (AC 250 V, 2 A), contact hysteresis setting (0–20 digits), moving average time setting (0–20 s), analog output scaling, zero-hold external signal input (dry contact) |
Show next