- All
- Favorite
- Popular
- Most rated
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Portable Gas Detector |
| Detection Principle | Electrochemical / PID / Catalytic Combustion / Infrared / Thermal Conductivity (configurable per gas) |
| Detection Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–100% LEL (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.1% LEL (0–100% LEL), 0.001% vol (0–99.999% vol) |
| Accuracy | ≤ ±3% FS (higher accuracy optional) |
| Response Time | T90 ≤ 20 s |
| Protection Rating | IP65 |
| Explosion-Proof Certification | Exia II CT4 |
| Dimensions | 178 × 70 × 40 mm |
| Weight | 300 g |
| Battery | 3.7 VDC, 4600 mAh Li-polymer (rechargeable via USB, operational during charging) |
| Operating Temperature | −40 °C to +70 °C |
| Sample Flow Rate | 500 mL/min (integrated pump suction) |
| Data Storage | 100,000 entries (expandable), USB export supported |
| Display | 2.31″ 320×240 color TFT screen with icon-based UI |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 18204.2–2014, GB 12358–2006, JJG 693–2011 |
| Brand | Eranntex |
|---|---|
| Model | DOAS-2000 |
| Detection Principle | UV Differential Optical Absorption Spectroscopy (DOAS) |
| Measurement Range | 0–2 to 0–2000 ppm (configurable) |
| Operating Temperature | −40 °C to +600 °C (standard), up to +1300 °C (custom) |
| Sampling Humidity | 0–99% RH |
| Protection Rating | IP66 (outdoor, explosion-proof optional) |
| Sampling Flow Rate | 4 L/min (standard), up to 10 L/min (optional) |
| Data Storage | 16 GB internal (daily folder-based archiving) |
| Output Signals | 4–20 mA, RS485, dry contact outputs |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions | 700 × 430 × 400 mm (H × W × D) |
| Brand | Eranntex |
|---|---|
| Model | MS500-MEK |
| Detection Principle | Electrochemical (Standard), Optional IR/PID/Catalytic/Thermal Conductivity |
| Gas Measured | Methyl Ethyl Ketone (MEK, C₄H₈O) |
| Display | 2.5" HD Color TFT Screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight & Powerful Water Jet Resistant |
| Explosion Protection | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Operating Temperature | −40 °C to +70 °C |
| Battery | Rechargeable 6000 mAh Polymer Li-ion |
| Runtime | Up to 20 h (typical, single-gas, pump off) |
| Data Storage | 100,000 entries (expandable) |
| Communication | USB, RS232, Bluetooth (optional) |
| Sampling Method | Built-in Pump with >10 m Sampling Distance |
| Filtration | Integrated Water Vapor & Particulate Filter |
| Calibration | Multi-point Target Gas Calibration |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 34004–2017, GB 12358–2006 |
| Alarm Modes | Visual (LED/Screen), Audible (≥85 dB), Vibration, Undervoltage & Fault Indication |
| Units | ppm, mg/m³, %LEL, %Vol (auto-converted via molecular weight input) |
| Humidity & Temp Measurement | Optional Integrated Sensor (±2% RH, ±0.5 °C) |
| Software Support | PC-based Data Analysis Suite with Audit Trail, Export (CSV/XLS), Print & Trend Graphing |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-CL2 |
| Price Range | USD 700 – 1,400 (FOB Shenzhen) |
| Detection Principle | Electrochemical (standard for Cl₂) |
| Measurement Range | 0–10 ppm (default), configurable up to 0–50,000 ppm |
| Resolution | 0.01 ppm (0–10 ppm), 0.1 ppm (0–1,000 ppm) |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Output Signals | 4–20 mA (3-wire/4-wire), RS485 Modbus RTU, relay outputs (2 x SPDT) |
| Enclosure Rating | IP65 |
| Explosion Protection | Exd IIC T6 Gb (CNEx17.3959) |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Power Supply | 12–36 VDC (24 VDC nominal, 1 A min) |
| Dimensions (L×H×W) | 238 × 210 × 90 mm (with beacon), 238 × 152 × 90 mm (without beacon) |
| Weight | 1.8 kg |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PTM600-CL2 |
| Price | USD 1,150 (FOB Guangdong) |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS600-CH2O |
| Detection Principle | Electrochemical Sensor |
| Measurement Ranges | 0–10 ppm, 20 ppm, 50 ppm, 100 ppm, 1000 ppm, 5000 ppm, 100% LEL (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.1% LEL (0–100% LEL), 0.001% Vol (0–99.999% Vol) |
| Repeatability | ≤±1% FS |
| Sampling Method | Built-in pump suction (500 mL/min) |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | –40 °C to +70 °C (optional high-temp sampling probe supports up to 1300 °C flue gas) |
| Temperature Measurement | –40 °C to +70 °C (±0.3 °C accuracy, optional) |
| Humidity Measurement | 0–100% RH (±2% RH accuracy, optional) |
| Ingress Protection | IP67 |
| Explosion Protection | Ex ia II CT4 |
| Battery | 3.7 V DC, 6000 mAh Li-polymer (with overcharge/over-discharge/short-circuit/thermal protection) |
| Data Storage | 100,000 records standard |
| Display | 2.5″ 320×240 color TFT screen |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Weight | 350 g |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | MS104K-C8H10 |
| Instrument Type | Portable Gas Detector |
| Detection Target | Xylene (C₈H₁₀) |
| Detection Principle | PID (Photoionization Detection), Catalytic Combustion, or Thermal Conductivity (selectable) |
| Detection Range | 0–10 ppm / 0–100 ppm (customizable) |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm) |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤30 s |
| Recovery Time | ≤30 s |
| Display | 2.31″ 320×240 Color TFT Screen |
| Data Storage | 100,000 entries (real-time, timed, or alarm-triggered) |
| Power Supply | 3.7 V DC, 2100 mAh Rechargeable Polymer Battery |
| Operating Temp. | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Temp. Measurement (optional) | −40°C to +70°C, ±0.5°C |
| Humidity Measurement (optional) | 0–100% RH, ±3% RH |
| Protection Rating | IP65 |
| Explosion-Proof Certification | Exia II CT4 Ga |
| Dimensions | 130 × 68 × 34 mm (L×W×H) |
| Weight | 200 g |
| Certifications | CMC (China Metrology Accreditation), GB Standard Compliance |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PTM600-N2O |
| Detection Principle | Infrared (IR), Electrochemical (EC), PID, Catalytic Combustion, Thermal Conductivity |
| Detection Range (N₂O) | 0–100 ppm / 0–5000 ppm / 0–100% Vol (IR-based, selectable at order) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 0.001% Vol (0–99.999% Vol) |
| Accuracy | ≤±2% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Sampling Method | Integrated pump suction (800 mL/min) with particulate/moisture filter |
| Display | 3.5″ color TFT LCD (320×240) |
| Operating Temperature | −40°C to +70°C |
| IP Rating | IP66 |
| Explosion Protection | Exia II CT4 (Intrinsically Safe) |
| Battery | 3.7 VDC, 10800 mAh Li-polymer (rechargeable, with overcharge/overdischarge/short-circuit/thermal protection) |
| Data Storage | Standard 100,000 records |
| Communication | Bluetooth v5.0, USB, RS232 (auto-recognizing) |
| Certifications | CMC (China Metrology Accreditation), GB standard-compliant |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS500-SO2 |
| Detection Principle | Electrochemical |
| Measurement Range | 0–10 ppm, 0–100 ppm (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.01 mg/L (0–200% mg/L), 0.1% LEL, 0.01% Vol, 0.001% Vol |
| Repeatability | ≤±2% FS |
| Sampling Method | Built-in suction pump |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 0–100% RH |
| IP Rating | IP66 |
| Explosion Protection | Ex ia IIC T4 Ga |
| Compliance | GB 15322.3–2019, GB 3836.1–2010, GB 3836.4–2010 |
| Battery | 3.7 VDC, 6000 mAh Li-polymer |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Weight | 350 g |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS400-CH4 |
| Pricing | Upon Request |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | LMIC-600-CH3Br |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Range | 0–100 ppm CH₃Br |
| Resolution | 0.01 ppm (0–100 ppm) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA, 3 relay outputs |
| Environmental Rating | IP66, Exd IIC T6 Gb |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Power Supply | 12–36 VDC |
| Display | 2.5″ color LCD |
| Compliance | GB 15322.1–2019, GB 3836.1/2–2010, CMC certification, EMI/EMC compliant |
| Brand | Eranntex |
|---|---|
| Model | MS500-O2 |
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Detection Principle | Electrochemical (standard for O₂), optional IR/PID/catalytic bead/thermal conductivity |
| Detection Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–200% vol (customizable) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.01 mg/L (0–200 mg/L), 0.01% vol |
| Accuracy | ≤±2% FS (higher accuracy available upon customization) |
| Operating Temperature | −40 °C to +70 °C (with ±0.5 °C temperature measurement accuracy, optional) |
| Humidity Measurement | 0–100% RH (±3% RH accuracy, optional) |
| Sampling Method | Integrated pump suction (500 mL/min), extendable sampling distance >10 m |
| Display | 2.5″ 320×240 color TFT screen |
| Data Storage | 100,000 records (expandable) |
| Communication | USB, RS232, Bluetooth (optional) |
| Power Supply | Rechargeable 3.7 V / 6000 mAh Li-polymer battery with overcharge/overdischarge/short-circuit/overtemperature protection |
| Enclosure Rating | IP66 |
| Explosion Protection | Exia II CT4 (intrinsic safety) |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Weight | 350 g |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MIC-500S-NH3 |
| Instrument Type | Online Gas Detector |
| Output Options | 4–20 mA (2-/3-/4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Relay Outputs (2 × SPDT) |
| Certifications | CMC License, Ex d IIB T6 Gb Explosion Protection Certification |
| Communication | Wired (RS485), LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF up to 5 km) |
| Remote Operation | Infrared remote control (15 m, no-open-cover configuration & calibration) |
| Calibration | Auto-zero tracking, multi-point calibration support, OEM/ODM available |
| Compliance | GB/T 34007–2017, GB 3836.1–2010, GB 3836.2–2010, JJG 555–1996 |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS600-C2H₆ |
| Detection Gas | Ethane (C₂H₆) |
| Detection Range | 0–100% LEL |
| Resolution | 0.1% LEL (0–100% LEL) |
| Detection Principle | Catalytic Combustion (for C₂H₆), Optional IR/PID/EC/Thermal Conductivity |
| Accuracy | ≤±1% FS |
| Linearity | ≤±1% |
| Repeatability | ≤±1% |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Display | 2.5" 320×240 TFT color screen |
| Sampling Method | Built-in suction pump (500 mL/min) |
| Protection Rating | IP67 |
| Explosion Protection | Ex ia II CT4 |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +85°C |
| Humidity Range | 0–99% RH (with integrated particulate/moisture filter) |
| Battery | 3.7 V DC, 6000 mAh Li-polymer (overcharge/over-discharge/short-circuit/thermal protection) |
| Data Storage | 100,000 records standard |
| Communication | USB (data & charging), RS232, Bluetooth, GPRS (optional) |
| Weight | 350 g |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Brand | Eranntex |
|---|---|
| Model | MS104K-AsH₃ |
| Detection Principle | Electrochemical / Catalytic Combustion / Infrared (configurable) |
| Detection Range | 0–10 ppm or 0–100 ppm AsH₃ (customizable) |
| Resolution | 0.01 ppm (AsH₃), 0.1% LEL, 0.01% Vol |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤30 s |
| Recovery Time | ≤30 s |
| Display | 2.31″ 320×240 color TFT screen |
| Data Storage | 100,000 entries (timestamped, configurable storage modes) |
| Battery | 3.7 V DC, 2100 mAh Li-polymer |
| Operating Temp. | −40 °C to +70 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| IP Rating | IP65 |
| Explosion Protection | Exia II CT4 Ga |
| Dimensions | 130 × 68 × 34 mm |
| Weight | 200 g |
| Certifications | CPA Type Approval (China), GB Standard Compliance |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-300-H2 |
| Hydrogen Generation Principle | Electrochemical & Thermal Conductivity |
| Output Flow Rate | 600 mL/min |
| Output Pressure | 0–100 ppm (Note: This is a typographical inconsistency in source |
| Hydrogen Purity | 99.99% |
| Power Consumption | 100 W |
| Detection Principle (Transmitter) | Electrochemical & Thermal Conductivity |
| Measurement Range | 0–100 ppm / 0–1000 ppm / 0–50,000 ppm / 0–100% LEL / 0–99.99% vol (configurable) |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.01% vol |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤30 s |
| Operating Temperature | −40°C to +70°C |
| Humidity Range | 10–95% RH (non-condensing) |
| Output Signals | 4–20 mA (3-wire), RS485 Modbus RTU, optional 0–5 V / 0–10 V / 1–5 V |
| Explosion Protection | Ex d IIC T6 Gb (Certificate No.: CNEx17.3959) |
| IP Rating | IP65 |
| Dimensions (L×H×W) | 203×180×65 mm (without beacon) |
| Weight | 1.0 kg |
| Brand | Eranntex |
|---|---|
| Model | PTM600-HBr |
| Detection Principle | Electrochemical (standard), Optional IR/PID/TC/Catalytic Combustion |
| Detection Range | 0.001 ppm to 99.999 %Vol (auto-ranging, specified at order) |
| Resolution | 0.001 ppm (low-range), 0.001 %Vol (high-range) |
| Display | 3.5-inch HD color TFT screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight, powerful water jet resistant |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb), CMC Certified |
| Sampling Method | Built-in explosion-proof diaphragm pump with integrated hydrophobic particulate filter |
| Sampling Distance | >10 m (with standard sampling hose) |
| Data Storage | Standard 100,000 records (expandable via SD card or USB mass storage) |
| Communication Interfaces | USB 2.0, RS232, Bluetooth 5.0 |
| Power Supply | 10,800 mAh Li-polymer battery (rechargeable via USB, supports hot-swap operation) |
| Operating Temperature | −40 °C to +70 °C (instrument) |
| Environmental Compensation | Integrated capacitive digital temperature/humidity sensor (optional) with real-time sensor compensation |
| Alarm Types | Dual-level (low/high), range, TWA, STEL |
| Calibration | Multi-point span calibration, zero auto-tracking, calibration log with timestamp and operator ID |
| Compliance | Meets GB/T 34004–2017, JJG 693–2011, ISO 16000-25, ASTM D6792, and supports 21 CFR Part 11 audit trail when used with compliant host software |
Show next