Suspended Solids Analyzer
Filter
Showing 31–45 of 45 results
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PSS-200 |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Photometry (Turbidimetric Absorption at 850 nm) |
| Range | 0–1000 mg/L |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ ±2% FS |
| Resolution | 0.01 mg/L |
| Power Supply | Rechargeable Lithium-ion Battery |
| Weight | 500 g |
| Dimensions | 80 × 230 × 55 mm |
| Optical System | Narrow-band Interference Filter + Imported Long-life LED Light Source |
| Data Storage | 20 Calibration Curves + 199 Measurement Records |
| Interface | USB 2.0 |
| Enclosure Rating | IP65 |
| Housing Material | Molded ABS Polymer |
| Data Protection | Auto-Save with Power-Fail Backup |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TSS-200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Range | 0–1000 mg/L |
| Accuracy | ≤ ±3% FS |
| Repeatability | ≤ ±2% FS |
| Resolution | 0.01 mg/L |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC (220 ±10%) V, 50 Hz |
| Light Source | Imported high-intensity LED (100,000-hour lifetime) |
| Optical System | Narrow-band interference filter |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | 20 built-in calibration curves + 400 measurement records (non-volatile memory) |
| Connectivity | USB port for data export |
| Optional | Thermal printer support |
| Housing Material | Molded ABS with corrosion resistance |
| Microcontroller | 16-bit low-power MCU |
| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Model | 6B-50SS (V9) |
| Measurement Range | 0–200 mg/L |
| Accuracy | ≤ ±10% |
| Repeatability | ≤ ±5% |
| Measurement Time | 1 minute per sample |
| Calibration Curves | 5 user-configurable curves |
| Data Storage Capacity | 5,000,000 measurement records |
| Light Source | Cold LED with Narrow-band Interference Filter (Lifetime ≥ 100,000 hours) |
| Display | Large-backlit LCD with Chinese GUI |
| Connectivity | Optional thermal printer interface (not standard) |
| Brand | TUNE VOLT |
|---|---|
| Model | TW-5258 |
| Origin | Beijing, China |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Range | 0–1000 mg/L |
| Minimum Resolution | 0.01 mg/L |
| Accuracy | ≤ ±2% F.S. |
| Repeatability | ≤ 3% |
| Optical Drift | < 0.002 A in 20 min |
| Dimensions (with printer) | 340 mm × 250 mm × 130 mm |
| Dimensions (without printer) | 266 mm × 200 mm × 130 mm |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 0.5 Hz |
| Weight | 4 kg |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SS |
| Quotation | Upon Request |
| Instrument Type | Laboratory |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | PC-2200/2300 |
| Particle Size Range | 0.5–100 µm |
| Dimensions | 120 × 355 × 114 mm |
| Weight | 2.7 kg |
| Power Supply | 230 VAC / 50 Hz |
| Sample Vial ID | 15–60 mm inner diameter |
| Vial Material | Optically clear, scratch-free borosilicate glass |
| Calibration Standards | NIST-traceable, argon-sealed polystyrene microsphere suspensions (3 vials), certified stability >10 years |
| Software | SuperCount (real-time particle count, mean diameter, mass distribution, % distribution, standard deviation, TSS estimation) |
| Brand | YST Environmental |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–5000 mg/L (extendable to 0–50000 mg/L) |
| Measurement Principle | Dual-beam infrared scattering and transmission hybrid optics |
| Output Signals | 4–20 mA analog output, RS485 digital interface (HJ 212 protocol compliant) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | −10 °C to +55 °C |
| Ingress Protection | IP68 |
| Installation Options | Submersible or flow-through configurations |
| Cleaning Mechanism | Integrated air-pulse auto-cleaning system |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–500 / 0–1000 / 0–5000 mg/L (field-selectable) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Output Signals | 4–20 mA analog, RS485 digital |
| Power Supply | AC 220 V ±10% @ 50/60 Hz or DC 24 V ±10% |
| Installation | Submersible |
| Probe IP Rating | IP68 |
| Enclosure IP Rating | IP65 |
| Compliance | Designed for continuous in-situ SS monitoring per ISO 7027 (turbidity correlation), ASTM D3977, and EPA Method 160.1 principles |
| Brand | YST (Dalian Yist Instrument Co., Ltd.) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Infrared Dual-Scatter Optical Detection |
| Range | 0–5000 mg/L (extendable to 0–20,000 mg/L) |
| Accuracy | ±2% FS (0–100 mg/L), ±5% FS (100–5000 mg/L) |
| Output | RS485 with Modbus RTU Protocol |
| Power Supply | DC 12–24 V, <50 mA avg. |
| Operating Temperature | −5 to +50 °C |
| Humidity | <85% RH (non-condensing) |
| Enclosure Rating | IP68 |
| Housing Material | 316 Stainless Steel + Polyoxymethylene (POM) |
| Brand | YST (Dalian Yist Environmental Technology Co., Ltd.) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Infrared Scattering (880 nm) |
| Range | 0–50,000 mg/L (multi-range configurable) |
| Power Supply | DC 12–24 V, <50 mA avg. |
| Output Signals | 4–20 mA analog, RS485 digital (Modbus RTU) |
| Sensor IP Rating | IP68 |
| Host IP Rating | IP65 |
| Sensor Operating Temp. | −10 to 60 °C |
| Host Operating Temp. | 0 to 50 °C |
| Installation Options | Top-mount, side-mount, submersible |
| Sensor Material | 316 stainless steel |
| Housing Material | POM engineering plastic |
| Brand | YST (Dalian Yist Environmental Technology) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–20,000 mg/L |
| Accuracy | ≤ ±2% FS |
| Output Signal | 4–20 mA DC |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Ingress Protection | IP65 |
| Installation Options | Immersion or Flow-Through |
| Brand | Dalian YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–50 g/L (activated sludge), 0–400 g/L (silica) |
| Units | mg/L / ppm selectable |
| Accuracy | ±1–2% FS |
| Repeatability | ±1–2% |
| Operating Temp. | 0–50 °C |
| Max. Pressure | ≤10 bar |
| Flow Rate | 0.3–3 m/s |
| Output | 4–20 mA isolated |
| Communication | Modbus RTU/ASCII |
| Enclosure Rating | Transmitter IP65, Sensor IP68 |
| Power Supply | AC 220 V or DC 24 V |
| Weight | 6 kg |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–5000 mg/L SS, 0–80.0 °C |
| Accuracy | ±1.5% FS (SS), ±0.3 °C (Temp) |
| Resolution | 1 mg/L (SS), 0.1 °C (Temp) |
| Output | 4–20 mA & RS485 MODBUS RTU |
| Power Supply | 85–265 VAC ±10%, 50 ±1 Hz, ≤3 W |
| IP Rating | IP65 |
| Installation | Panel-mount / Wall-mount / In-line pipe mount |
| Operating Environment | −10 to +60 °C, ≤90% RH, non-corrosive, no strong magnetic field |
| Compliance | HJ 212–2017 (China Emission Monitoring Data Transmission Standard) |
| Brand | YST Instrument (Dalian) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Transmittance-Scattering Hybrid Optical Method |
| Range | 0–5000 mg/L |
| Accuracy | ≤±2% FS |
| Resolution | 1 mg/L |
| Response Time (T90) | ≤10 s |
| Operating Temp. (Sensor) | −10–80 °C |
| Operating Temp. (Transmitter) | 0–50 °C |
| Humidity | ≤90% RH (non-condensing) |
| pH Compatibility | 2–12 |
| Output Signals | Isolated 4–20 mA analog + RS485 digital (Modbus RTU) |
| Power Supply | AC 220 V ±10% 50/60 Hz or DC 24 V ±10% |
| Enclosure Rating | Sensor IP68, Transmitter IP65 |
| Cleaning | Integrated Automatic Wiper System |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–2000 NTU / 0–500 mg/L (switchable) |
| Accuracy | ±1.5% FS |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz or DC 24 V ±10% (optional) |
| Output Signal | 4–20 mA isolated (load < 750 Ω) |
| Ingress Protection | IP65 |
| Operating Temperature | 0–60 °C |
| Data Logging | 1 month @ 5-min intervals (non-volatile memory, 10-year data retention after power loss) |
| Installation | Flow-through sensor |
| Compliance | HJ 212–2017 protocol support for environmental monitoring platform integration |