| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LipoSofast |
| Sample Volume per Cycle | 1 mL (2 × 500 µL syringes) |
| Minimum Sample Volume | 0.1 mL |
| Residual Volume | 0 µL |
| Available Polycarbonate (PC) Membrane Pore Sizes | 50, 100, 200, 400, and 800 nm |
| Temperature Compatibility | Water-bath compatible for thermal control (e.g., 4–40 °C) |
| Weight | < 2 kg |
| Construction | Borosilicate glass syringes, stainless steel housing, chemically resistant seals |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | High-Pressure Homogenizer |
| Structural Design | Modular Pump Head |
| Valve Material | SAF2507 Super Duplex Stainless Steel |
| Pressure Regulation | Manual & Pneumatic |
| Control Interface | Touchscreen Panel |
| Data Logging | Real-Time Pressure Monitoring & Exportable Records |
| Safety Features | Adjustable Pressure Limit with Audible/Visual Alarm |
| Optional Modules | Variable-Frequency Flow Control, Automated Pressurization, PLC Integration, Temperature Control, Multi-Stage Homogenization, Closed-Loop Circulation, Pre-Processing Unit |
| Flow Rate Range | 80–2000 L/h |
| Maximum Operating Pressure | 1500 bar (standard), 1000 bar (high-flow configurations) |
| Compliance | Designed for GMP-aligned process development and scale-up per ISO 22411, ASTM E2456, and USP <1119> guidelines |
| Brand | Aitesen |
|---|---|
| Model | HPEx-L1 |
| Type | Manual Liposome Extrusion Device |
| Sample Volume Range | 0.1–1.0 mL per run |
| Residual Volume | 0 mL |
| Polycarbonate (PC) Membrane Diameter | 19 mm |
| Available Membrane Pore Sizes | 50 nm, 100 nm, 200 nm, 400 nm, 800 nm |
| Temperature Compatibility | Water-bath compatible (ambient to 60 °C) |
| Weight | <2 kg |
| Cleaning | Fully disassemblable |
| Brand | Aitesen |
|---|---|
| Model | TBX001 |
| Instrument Type | High-Pressure Extruder |
| Dimensions (W×D×H) | 80 × 140 × 60 mm |
| Sample Volume Range | 0–10 mL |
| Maximum Operating Pressure | 1000 psi |
| Final Particle Size Range | 50–1000 nm |
| Polydispersity Index (PDI) | <0.1 achievable |
| Operating Temperature Range | 5–75 °C |
| Maximum Lipid Concentration | 200 mg/mL |
| Construction Materials | 316L stainless steel body, polycarbonate (PC) track-etched membranes, FDA-compliant PU/PTFE seals |
| Temperature Control | Jacketed with external recirculating chiller |
| Compliance | Designed for GMP-compliant cleanroom use |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | RSS-L1 |
| Type | Benchtop Sterilizer |
| Max Temperature | 0–150 °C (±0.1 °C) |
| Chamber Volume Capacity | 10–2000 mL |
| Max Working Pressure | 0.3 MPa |
| Total Power | 7.5 kW |
| Sample Capacity | 1–10 vessels |
| Temperature Sensors | ≥3 independent RTD probes |
| Output Parameters | Temperature, Pressure, F₀, Time, Rotation Speed, Steam Flow (where applicable) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Extru25-20 |
| Instrument Type | High-Pressure Pneumatic Extruder |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Sample Volume Range | 0–20 mL |
| Maximum Operating Pressure | 25 MPa |
| Final Particle Size Range | 50–1000 nm |
| Maximum Product Concentration | 200 mg/mL |
| Operating Temperature Range | 5–80 °C |
| Construction Material | SS316L |
| Membrane Diameter | 25 mm |
| Power Source | Compressed Nitrogen Gas |
| Residual Volume | < 10 µL |
| Temperature Control | Integrated Jacketed Chamber with External Circulator Compatibility |
| Regulatory Compliance | All elastomeric components (O-rings, gaskets) FDA-compliant per 21 CFR §177.2600 |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | HPH-L2 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 545 × 755 × 494 mm |
| Maximum Pressure | 2000 bar |
| Maximum Feed Particle Size | 500 µm |
| Flow Rate | 5–15 L/h |
| Minimum Sample Volume | 15 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 1.5 kW |
| Material of Wetted Parts | SAF2507 Super Duplex Stainless Steel |
| Compliance | Manufactured per EU Machinery Directive 98/37/EC (MD) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPE-L1 |
| Instrument Type | High-Pressure Microfluidic Emulsification System |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Flow Rate Range | 0.1–200 mL/min |
| Pressure Range | 0–25 MPa |
| Temperature Control Range | 4–100 °C |
| Flow Accuracy | ≤ ±1% |
| Flow Repeatability | ≤ 1% |
| Pressure Pulsation | ≤ 0.1 MPa |
| Pressure Accuracy | ≤ 0.1 MPa |
| Minimum Channel Width | 20 µm |
| Particle Size Output | <100 nm |
| Polydispersity Index (PDI) | <0.1 |
| Brand | Aitesen |
|---|---|
| Model | TLEx-100 |
| Type | Nitrogen-Driven Membrane Extrusion System |
| Max. Sample Volume | 100 mL |
| Dimensions (W×D×H) | 80 × 140 × 60 mm |
| Construction Materials | SS316L Support/Filter Plates, Polycarbonate (PC) Track-Etched Membranes, FDA-Certified PU/PTFE Seals |
| Temperature Control | Jacketed Heating (up to 70 °C) |
| Pressure Source | Regulated Compressed Nitrogen |
| Sterilization Compatibility | Autoclavable Components (121 °C, 20 min) |
| Compliance | GMP-Aligned Design, Suitable for ISO Class 5–7 Cleanrooms |
| Particle Size Output | Typically <100 nm, PDI <0.1 (with appropriate membrane pore size and cycling protocol) |
| Brand | Aitesen |
|---|---|
| Model | OLExS-Pd |
| Instrument Type | Microfluidic Extrusion System |
| Processing Volume | 100–5000 mL |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Origin | Jiangsu, China |
| Supplier Type | Authorized Distributor |
| Regulatory Classification | Domestic Laboratory-Grade Equipment |
| Brand | AITSEN |
|---|---|
| Model | HPH-L3 |
| Type | High-Pressure Piston-Type Homogenizer |
| Construction | Modular Pump Head Design |
| Wetted Materials | SAF2507 Super Duplex Stainless Steel |
| Maximum Operating Pressure | 1800 bar |
| Flow Rate Range | 10–40 L/h |
| Minimum Sample Volume | 30 mL |
| Dimensions (W×D×H) | 658 × 868 × 920 mm |
| Weight | 280 kg |
| Noise Level | ≤65 dB(A) |
| Power Supply | 5.5 kW |
| Compliance | Manufactured per EU Machinery Directive 98/37/EC (MD) |
| Sterilization & Cleaning | CIP-Compatible, Autoclavable Components |
| Control Interface | Touchscreen HMI with Real-Time Pressure Monitoring, Data Logging, and Export (CSV/Excel) |
| Optional Systems | Frequency-Controlled Flow Regulation, Pneumatic/Automatic Pressure Actuation, PLC-Based Process Logic Control, Jacketed Temperature Control, Multi-Stage Homogenization, Closed-Loop Recirculation, Pre-Conditioning Module |