Empowering Scientific Discovery

Suzhou Aitson Pharmaceutical Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLDS-L2
QuotationUpon Request
Minimum Sample Volume≤30 mL
Pressure Range−1 to 5 bar (with integrated pressure sensors)
Maximum Peristaltic Flow Rate≥2200 mL/min
Weight Measurement Accuracy±0.5% (0–4100 g)
Controlled ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Operation ModeFully Automated PLC-Controlled TFF
Compatible MembranesPES and Cellulose-based Cassettes & Hollow Fiber Modules (MWCO: 5–1000 kDa
Effective Area0.01–0.1 m²)
Software ComplianceFDA 21 CFR Part 11 Audit Trail Enabled
User Access LevelsThree-Tier Password Protection (Operator / Process Engineer / Administrator)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLDS-L1
Price RangeUSD 14,000 – 28,000
Minimum Sample Volume30 mL
Pressure Range−1 to 5 bar
Flow Rate Range1–2200 mL/min
Weight Capacity0–4100 g
Displayed ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Operation ModeManual
Compatible VesselsGlass or Stainless Steel Containers
Membrane FormatsPES or Cellulose-Based Cassettes & Hollow Fiber Modules
MWCO Options5–1000 kDa
Effective Filtration Area0.01–0.1 m²
ComplianceDesigned for GLP-compliant lab-scale process development and tech transfer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAITESEN
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLDS-L2
QuotationUpon Request
Minimum Sample Volume≤30 mL
Pressure Range−1 to 5 bar (with integrated pressure sensors)
Maximum Recirculation Flow Rate≥2200 mL/min
Weight Measurement Accuracy±0.5% (0–4100 g)
Controlled ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Operation ModeFully Automated PLC-Controlled TFF
Compatible MembranesPES and Cellulose-based Cassettes & Hollow Fiber Modules (MWCO: 5–1000 kDa
Effective Filtration Area0.01–0.1 m²)
Software ComplianceFDA 21 CFR Part 11–compliant audit trail, role-based access control (Operator / Process Engineer / Administrator)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLDS-L2
PricingAvailable Upon Request
Minimum Sample Volume30 mL
Pressure Range−1 to 5 bar
Flow Rate Range1–2200 mL/min
Weight Capacity0–4100 g
Measurable ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Operation ModeFully Automated
Compatible VesselsGlass & Stainless Steel Containers
Membrane FormatsPES & Cellulose-Based Cassettes, Hollow Fiber Modules
MWCO Range5–1000 kDa
Effective Membrane Area0.01–0.1 m²
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLDS-L2
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLDS-L1
PricingUpon Request
Minimum Sample Volume≤30 mL
Pressure Range−1 to 5 bar
Max. Permeate Flow Rate≥2200 mL/min
Weight Capacity0–4100 g
Weighing Accuracy±0.5%
Real-time Monitored ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Compatible Membrane FormatsPES & Cellulose-based Cassettes and Hollow Fiber Modules
MWCO Range5–1000 kDa
Effective Filtration Area0.01–0.1 m²
ComplianceFDA 21 CFR Part 11 Audit Trail Ready, Designed for GLP/GMP-adjacent R&D Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAitesen
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLDS-L1
PricingUpon Request
Minimum Sample Volume≤30 mL
Pressure Range−1 to 5 bar
Max Flow Rate≥2200 mL/min
Weight Capacity0–4100 g
Weighing Accuracy±0.5%
Measured ParametersPf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop)
Compatible MembranesPES and Cellulose-based Cassettes & Hollow-Fiber Modules
MWCO Range5–1000 kDa
Effective Membrane Area0.01–0.1 m²
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0