Synthesis/Reaction Equipment
Filter
Showing 301–330 of 735 results
| Brand | Huayan |
|---|---|
| Origin | Jiangsu, China |
| Model | ML08S-3 |
| Temperature Range | 0–300 °C |
| Pressure Rating | Atmospheric (open-vessel operation) |
| Microwave Power Output | 0–1000 W (non-pulsed continuous & variable-pulse dual mode) |
| Microwave Frequency | 2.45 GHz ±50 MHz |
| Stirring | Integrated magnetic stirring + optional top-mounted mechanical stirring |
| Reaction Cavity Volume | 23 L |
| Temperature Sensor | Pt100 contact probe, accuracy ±1 °C |
| Safety | Microwave choke-sealed top ports, interlocked door, magnetron thermal protection |
| Compliance | Meets GB 4706.21 / GB 10436 (Chinese national standards for microwave leakage <5 mW/cm²) |
| Brand | Huayan |
|---|---|
| Origin | Jiangsu, China |
| Model | MY1500S / MY800S |
| Output Power | 0–1500 W (MY1500S) / 0–800 W (MY800S), continuously adjustable |
| Frequency | 2450 MHz ±50 MHz |
| Waveguide Interface | Standard BJ-26 or BJ-22 |
| Input Voltage | 220 V AC, 50 Hz |
| Cooling | Forced-air or water-cooled (configurable) |
| Safety Compliance | Meets GB 4706.21 & GB 10683 (Chinese National Standards for Microwave Leakage ≤5 mW/cm² at 5 cm) |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Model | HY-BH26FA, HY-BH22FA |
| Frequency | 2450 MHz ±25 MHz |
| Power Handling | 1 kW–15 kW |
| Waveguide Interface | BJ-26 (WR-340), BJ-22 (WR-430) |
| Insertion Loss (Forward) | ≤0.3 dB |
| Isolation | >20 dB |
| VSWR | ≤1.2 |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HF-1L |
| Instrument Classification | Jacketed Glass Reactor |
| Usable Volume | 1 L |
| Vessel Material | Borosilicate Glass (3.3) |
| Operating Pressure Range | Low-Pressure / Vacuum-Compatible |
| Maximum Vacuum Level | −0.095 MPa (absolute) |
| Jacket Inlet/Outlet | Standardized G1/2" Fittings |
| Stirring Drive | Top-Mounted Mechanical Stirrer with Imported Sealed Bearing Assembly |
| Sealing Materials | PTFE + Borosilicate Glass |
| Temperature Monitoring | Integrated Pt100 Sensor Port |
| Vacuum & Temperature Measurement | Optional Digital Dual-Parameter Display Unit |
| Drain Valve | Quick-Release PTFE-Ball Valve with Zero-Dead-Volume Design |
| Condenser Type | Standard All-Glass Dimroth or Coil Condenser (Configurable) |
| Base Frame | 316 Stainless Steel Support with Adjustable Feet |
| Compliance | Designed per GB/T 25187–2010 (Laboratory Glass Reactors), Compatible with ISO 3585 (Borosilicate Glass 3.3 Specifications) |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HX-CF5 |
| Instrument Classification | Jacketed Reactor |
| Usable Volume | Small-scale |
| Construction Material | Borosilicate Glass |
| Operating Pressure | Medium Pressure |
| Capacity | 5 L |
| Vacuum Capability | Not Designed for Vacuum Operation |
| Frequency | 2450 MHz ±50 MHz |
|---|---|
| Power Output | 0–1500 W (non-pulsed continuous & adjustable pulsed modes) |
| Temperature Range | 0–300 °C, accuracy ±1 °C |
| Temperature Sensor | Pt100 contact probe with corrosion-resistant tip |
| Timing Control | 0–900 min, resolution 1 s |
| Reaction Volume | 10–1000 mL |
| Stirring | Dual-mode (magnetic & mechanical, speed continuously adjustable) |
| Safety | Microwave leakage < GB 10436-2008 limit |
| Control System | Industrial PLC + full-color Chinese touchscreen HMI |
| Safety Interlocks | Magnetron overtemperature protection, door interlock, cavity shielding |
| Brand | Hyeyan |
|---|---|
| Origin | Jiangsu, China |
| Model | MG08S-3 |
| Microwave Power | 0–800 W (continuously adjustable) |
| Frequency | 2450 MHz ±50 MHz |
| Aperture Diameter | 28–40 mm |
| Timer Range | 0–900 min |
| Temperature Monitoring | High-precision RTD sensor |
| Cavity Material | Stainless steel |
| Safety Features | Magnetron thermal protection, interlocked door switch, microwave leakage < GB 10436-2008 limit |
| Brand | Hyeyan |
|---|---|
| Model | MY200S |
| Output Type | LY16 Coaxial or BJ26 Waveguide |
| Max. Output Power | 200 W (linearly adjustable) |
| Operating Frequency | 2450 ± 50 MHz |
| Input Voltage | AC 220 V ± 10%, 50 Hz |
| Input Apparent Power | < 500 VA |
| Anode Current | Continuously Adjustable with Overload Protection |
| Housing | Full Aluminum with Powder-Coated Finish |
| Safety | Multi-Level Interlock Protection, Overcurrent Protection, Real-Time Control Logic |
| Compliance | Designed for integration into CE-compliant microwave synthesis platforms per IEC 61000-6-3/6-4 and EN 61010-1 |
| Brand | Hyeyan |
|---|---|
| Model | ZDM-1000 |
| Microwave Power | 0–1000 W (continuously adjustable, linear control) |
| Frequency | 2450 MHz ± 50 MHz |
| Input Power | 220 V, 50 Hz |
| Temperature Monitoring Range | 0–500 °C |
| Temp. Control Accuracy | ±1 °C |
| Waveguide Interface | Standard WR-340 (or equivalent) |
| Safety Compliance | Meets GB 10436–2008 (China National Standard for Microwave Leakage Limits) |
| Control Interface | Industrial-grade color touchscreen HMI (Chinese-language UI) |
| Cooling | Forced-air magnetron cooling with thermal interlock |
| Protection Features | Circulator-based isolation, full-reflection tolerance, IR-based real-time temperature feedback, multi-level hardware safety interlocks |
| Brand | Hyeyan |
|---|---|
| Origin | Jiangsu, China |
| Model | ZDM-2B |
| Microwave Frequency | 2450 MHz ± 50 MHz |
| Output Power Range | 0–1500 W (continuous linearly adjustable) |
| Power Control Modes | Continuous mode & programmable pulsed mode |
| Pulse Period & Pulse Width | User-definable via touchscreen interface |
| Temperature Monitoring Range | 0–500 °C |
| Temperature Accuracy | ±1 °C |
| Input Power | 220 V, 50 Hz |
| Waveguide Output | Standard WR-340 |
| Safety Compliance | Meets GB 10436-2008 (China National Standard for Microwave Leakage) |
| Cooling Interface | Reflux port with microwave suppression on multi-mode cavity |
| Stirring Options | Built-in magnetic stirrer (multi-mode cavity) + optional mechanical stirring |
| Tuning System | Terminal tuning & focal point adjustment for single-mode cavity |
| Real-time Diagnostics | Integrated waveguide coupler, crystal detector, and tuner for standing-wave observation and impedance matching |
| Optional Connectivity | RS-485 interface for PC-based control and third-party software integration |
| Brand | Hyway |
|---|---|
| Model | MG08S-2B |
| Origin | Jiangsu, China |
| Microwave Power | 0–900 W (continuous linear adjustment) |
| Frequency | 2450 MHz ±50 MHz |
| Temperature Range | 0–300 °C (±1 °C accuracy) |
| Temperature Sensor | Shielded Pt100 contact probe |
| Timer Range | 0–900 min |
| Cavity Volume | 23 L |
| Reaction Vessel Capacity | 10–1000 mL |
| Stirring | Dual-mode (built-in magnetic + external mechanical, both continuously adjustable) |
| Safety Features | Microwave leakage < GB 10436-2008 limit, interlocked door switch, magnetron overtemperature protection, waveguide-mounted microwave suppressors |
| Inlet/Outlet Ports | Two rear-mounted, wave-suppressed ports for gas/liquid feed or inert atmosphere purging |
| Reflux Interface | Top-mounted standard taper port with integrated microwave suppression |
| Brand | HyYan |
|---|---|
| Origin | Jiangsu, China |
| Model | MC8S-3 |
| Temperature Range | 0–300 °C |
| Pressure Condition | Ambient (Open-Vessel Operation) |
| Microwave Power | 0–1000 W (continuous, linearly adjustable) |
| Microwave Frequency | 2.45 GHz ± 50 MHz |
| Ultrasonic Power | 0–900 W (submersible transducer) |
| Ultrasonic Frequency | 25 kHz (auto-frequency tracking) |
| UV Wavelength | 365 nm |
| UV Power | 250 W |
| Stirring | Adjustable Magnetic Stirring |
| Reaction Volume Capacity | 10–1000 mL |
| Cavity Material | Stainless Steel |
| Safety Compliance | Meets GB 10436 (Chinese Microwave Leakage Standard) |
| Interface | RS-485 (MODBUS RTU), VGA video output, touchscreen HMI |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Double-Jacketed Glass Reactor with Baffle Plate |
| Capacity | 1 L |
| Jacket Type | Dual vacuum-insulated jacket |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Limit (ΔT) | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient pressure |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 22 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Dual-Jacketed Reactor |
| Capacity | 1 L |
| Jacket Type | Dual (inner & outer thermal isolation) |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock ΔT | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 21 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Filtration Reactor |
| Vessel Capacity | 1 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to ambient pressure |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 28 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Dual-Jacketed Baffle-Equipped Reactor |
| Capacity | 5 L |
| Jacket Type | Dual (inner heating/cooling jacket + outer vacuum insulation layer) |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Limit (ΔT) | 60 °C |
| Pressure Range | 666 Pa (0.5 mbar) to atmospheric pressure |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 28 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Dual-Jacketed Reactor |
| Capacity | 5 L |
| Jacket Configuration | Dual (inner heating/cooling jacket + outer vacuum insulation jacket) |
| Operating Temperature Range | −90 °C to +230 °C |
| Maximum Thermal Shock ΔT | 60 °C |
| Operating Pressure Range | 666 Pa (0.5 mbar) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Max Stirring Speed | 800 rpm |
| Footprint | 380 mm × 380 mm |
| Height | 1206 mm |
| Net Weight | 28 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Filter Reactor |
| Vessel Capacity | 5 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to atmospheric |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 33 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Pressurized Filtration Reactor |
| Vessel Capacity | 5 L |
| Construction | Single-layer borosilicate glass 3.3 vessel |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Pressure Rating | Full vacuum to 0.2 MPaG (2 barg) |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 × 2, SQG 24/40 × 4) |
| Maximum Stirring Speed | 200 rpm |
| Dimensions (W × D × H) | 455 mm × 432 mm × 1206 mm |
| Weight | 39 kg |
| Modular Configuration | Integrated filtration & drying capability |
| Sealing System | Reinforced magnetic or mechanical shaft seal with leak-proof base design |
| Filtration Base | Removable, pressure-rated sintered frit or filter plate assembly |
| Accessories Included | Pt100 temperature probe, analog pressure gauge, pressure relief valve, quick-connect fluid ports with integrated shut-off valves, PTFE/FFKM-sealed discharge valve |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | AG! 1L Pressure Filtration Reactor |
| Vessel Capacity | 1 L (Note: corrected from misleading “5L” in description |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | Full Vacuum to 0.2 MPa (2 bar(g)) |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (2 × SQG 29/42, 4 × SQG 24/40) |
| Max Stirring Speed | 200 rpm |
| Dimensions (W×D×H) | 455 mm × 432 mm × 1206 mm |
| Net Weight | 33 kg |
| Compliance | Designed per DIN 7080, EN ISO 15500-1, and CE Machinery Directive 2006/42/EC |
| Software Interface | None (standalone mechanical/electromechanical system) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 1000 Advanced |
| Reactor Type | Jacketed Glass Reactor |
| Usable Volume | 1 L |
| Operating Pressure Range | Low-pressure / Vacuum-compatible |
| Vacuum Level | 3 mbar |
| Construction Material | Borosilicate Glass 3.3 |
| Temperature Range | –50 °C to +200 °C |
| Stirrer Motor | EUROSTAR 100 control (Max. Torque: 100 N·cm) |
| Stirring Shaft Seal | High-integrity vacuum-rated mechanical seal |
| Vessel Fixation | DN 100 flange with FEP-coated O-ring |
| Lid Ports | 1 × NS 29/32 central, 2 × NS 29/32 lateral, 1 × NS 14/23 auxiliary |
| Drain System | LT 5.40 quick-drain module with valved thermal bath fluid lines |
| Control Interface | RS232 and USB |
| Software Integration | labworldsoft® 6 (optional external automation) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Advanced Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN 100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Bottom Valve | Spring-loaded PTFE-coated glass valve |
| Lid Ports | 1 × NS 29/32 central, 2 × NS 29/32 side, 1 × NS 14/23 |
| Stirrer | EUROSTAR 100 control with keyless chuck, integrated timer, overload protection & temperature input |
| Agitator Blade | PTFE-coated helical impeller |
| Seal Type | High-vacuum mechanical seal rated to 25 mbar |
| Software Control | labworldsoft® 6 (RS-232 optional) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Reactor |
| Model | EasySyn 1000 Starter |
| Vessel Capacity | 1 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Temperature Range | –50 °C to +200 °C |
| Maximum Vacuum | 3 mbar |
| Working Pressure | Low-pressure (up to 2 bar gauge, per IKA specification) |
| Stirring Torque | 60 N·cm |
| Flange Standard | DN 100 |
| Port Configuration | 1 × NS 29/32 (central), 2 × NS 29/32 (lateral), 1 × NS 14/23 |
| Sealing Material | FEP-coated O-ring |
| Valve Material | PTFE-lined bottom discharge valve |
| Stirrer Material | PTFE-coated helical impeller |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH, ≤2000 m altitude |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Starter Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 °C to +200 °C |
| Ultimate Vacuum | 3 mbar |
| Max. Stirring Torque | 60 N·cm |
| Flange Size | DN100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Jacketed Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Type | Overhead Digital Motor (EUROSTAR 60 digital) |
| Sealing | Chemically Resistant FEP-Coated O-Ring & High-Vacuum Shaft Seal |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 2000 Advanced |
| Reactor Type | Jacketed Glass Reactor |
| Usable Volume | 2 L |
| Operating Pressure Range | Low-pressure (up to 25 mbar vacuum) |
| Ultimate Vacuum | 3 mbar |
| Temperature Range | –50 °C to +200 °C |
| Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Motor | EUROSTAR 100 control, max. torque 150 N·cm |
| Stirring Shaft Seal | High-vacuum PTFE-sealed |
| Vessel Fixation | DN 150 clamp system with FEP-coated O-ring |
| Port Configuration | 1 × NS 29/32 central port, 2 × NS 29/32 side ports, 1 × NS 14/23 auxiliary port |
| Drain System | LT 5.40 quick-drain unit with integrated valves and thermostatic hose connections |
| Control Interface | RS232 and USB |
| Software Compatibility | labworldsoft® 6 (optional external automation) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 2000 Advanced Reactor System |
| Rated Volume | 2 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 400 mL |
| Operating Temperature Range | −50 to 200 °C |
| Ultimate Vacuum | 3 mbar (process vacuum), up to 25 mbar (seal rating) |
| Max. Stirring Torque | 100 N·cm |
| Flange Size | DN 150 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Material | Borosilicate Glass 3.3 (DIN ISO 3585), FEP-coated O-rings, PTFE-coated impeller, stainless steel frame |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EasySyn 2000 Starter |
| Reaction Vessel Capacity | 2 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Pressure Range | Low-pressure / Vacuum-compatible |
| Ultimate Vacuum | 3 mbar |
| Temperature Range | –50 °C to +200 °C |
| Stirring Torque | 60 N·cm |
| Flange Size | DN 150 |
| Port Configuration | 1 × NS 29/32 (center), 2 × NS 29/32, 1 × NS 14/23 |
| Sealing | FEP-coated O-ring |
| Discharge Valve | Spring-loaded PTFE-lined glass valve |
| Stirrer Shaft Seal | High-integrity vacuum-rated mechanical seal |
| Stirrer Type | PTFE-coated helical impeller |
| Stand Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Overall Dimensions (W × H × D) | 500 × 1050 × 580 mm |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH, ≤2000 m altitude |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 2000 Starter Reactor System |
| Rated Volume | 2 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 400 mL |
| Operating Temperature Range | −50 °C to +200 °C |
| Ultimate Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Max. Stirring Torque | 60 N·cm |
| Flange Size | DN 150 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Jacketed Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Type | Overhead Digital Motor (EUROSTAR 60 digital) |
| Sealing | High-performance FEP-coated O-ring & vacuum-rated mechanical shaft seal |
| Temperature Interface | Integrated Pt100 sensor port |
| Standard Ports | 1 × NS 29/32 central, 2 × NS 29/32 side, 1 × NS 14/23 auxiliary |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 500 Advanced |
| Vessel Capacity | 0.5 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Temperature Range | −50 °C to 200 °C |
| Maximum Vacuum | 3 mbar |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Stirrer | EUROSTAR 100 control (100 N·cm max torque) |
| Interface | RS232, USB |
| Compliance | CE, ISO 9001, GLP-supporting architecture |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 500 Advanced Reactor System |
| Rated Volume | 0.5 L |
| Minimum Usable Volume | 30 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Stirrer Type | Overhead EUROSTAR 100 control |
| Sealing | High-vacuum PTFE/FEP-coated shaft seal |
| Bottom Valve | Spring-loaded glass-safe discharge valve |
| Control Software | labworldsoft® 6 (RS232-controlled) |