| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 4102 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.4–20 m/s |
| Velocity Resolution | 0.1 m/s |
| Velocity Accuracy | ±(0.2 m/s + 2 % of reading) |
| Air Temperature Range | −10 to +50 °C |
| Air Temperature Accuracy | ±0.5 °C |
| Air Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| Relative Humidity Accuracy | ±2.5 %RH (5–95 %RH) |
| Relative Humidity Resolution | 0.1 %RH |
| Operating Environment | −10 to +50 °C, 0–100 %RH |
| Weight | 110 g (incl. batteries and protective cap) |
| Dimensions | 133 × 46 × 25 mm (with protective cap) |
| Protection Rating | IP10 |
| Power Supply | 2 × AAA batteries |
| Battery Life | up to 60 h (backlight off, typical use) |
| Measurement Update Rate | 0.5 s |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3340 |
| Channel Count | 2-channel |
| Compliance | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED alert |
| Software Integration | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Certification | Validated for GxP environments (GLP/GMP-aligned) |
| Power | Battery-operated (included) |
| Mounting | Wall-mountable (included bracket) |
| Calibration | Supplied with traceable calibration protocol |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | testo 830-T4 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Laser Aiming | Dual-point |
| Measurement Frequency | 2 Hz |
| IR Temperature Range | –30 to +400 °C |
| IR Accuracy | ±1.5 °C (–20 to 0 °C), ±2 °C (–30 to –20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| Response Time (IR) | 0.5 s |
| Contact Probe Input | Type K thermocouple (–50 to +500 °C, ±0.5 °C + 0.5 %, resolution 0.1 °C, response time 1.75 s) |
| Display | Backlit LCD |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 0563 0890 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Spectral Range | 7.5–14 µm |
| Detector Type | Uncooled Scanning Focal Plane Array (FPA) |
| Thermal Resolution | 640 × 480 pixels |
| NETD | < 40 mK @ 30 °C |
| Frame Rate | 33 Hz |
| Temperature Range | −30 to +100 °C (standard) |
| optional extended ranges | 0 to +350 °C and 0 to +650 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Handheld, battery-powered thermal imaging system |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0465 |
| Measurement Principle | Non-contact optical reflection (visible/infrared LED) |
| Distance Range | Up to 600 mm |
| Display | Single-line LCD |
| RPM Range | 1–99,999 rpm |
| Accuracy | ±0.02% of reading |
| Resolution | 0.01 rpm (1–99.99 rpm), 0.1 rpm (100–999.9 rpm), 1 rpm (1,000–99,999 rpm) |
| Data Hold | Min/Max/Avg/Last value storage |
| Included Accessories | Protective SoftCase, reflective tape, plastic instrument case, batteries |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3350 |
| Channel Count | Multi-channel |
| Certification | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED indicator (flashing) |
| Software Compatibility | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Included | Wall mount bracket, batteries, calibration certificate |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1052 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-20 to +100 °C), ±1.0 °C (-50 to -20.1 °C), ±1% of reading (+100.1 to +275 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| IP Rating | IP65 |
| Display | Backlit LCD (single-line) |
| Power Supply | LR44 button cell battery (80 h typical life) |
| Dimensions (with standard probe) | 148 × 38 × 195 mm |
| Weight (instrument only, standard probe) | 156 g |
| Response Time t₉₉ | 10 s (standard/long probe in liquid), 15 s (frozen goods probe in frozen meat ≈ 60 s) |
| Compliance | EN 13485, HACCP principles, FDA food safety guidelines |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 0460 |
| Measurement Principle | Non-contact optical reflection method |
| Distance Range | 10–40 cm |
| RPM Range | 100–29,999 rpm |
| Accuracy | ±0.02 % of reading |
| Resolution | 0.1 rpm (100–999.9 rpm), 1 rpm (1,000–29,999 rpm) |
| Response Time | 0.5 s |
| Display | Backlit LCD |
| Power Source | Included battery |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration certificate supplied |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2021 |
| Channel Count | Multi-channel |
| Sensor Type | Integrated capacitive humidity & NTC temperature sensors |
| Humidity Range | 0–100 %RH (non-condensing) |
| Humidity Accuracy | ±2.0 %RH (20–80 %RH, +25 °C), ±3.0 %RH (<20 or >80 %RH, +25 °C) |
| Annual Drift | ±1.0 %RH |
| Humidity Resolution | 0.1 %RH |
| Temperature Range | −10 to +50 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Data Storage Capacity | 40,000 readings |
| Battery Life | Up to 18 months (4 × AAA alkaline) |
| Power Options | USB-powered (optional external power unit) |
| Enclosure Rating | IP20 |
| Dimensions | 76 × 64 × 22 mm |
| Weight | 94 g |
| Operating Temp. | −10 to +50 °C |
| Wireless Protocol | IEEE 802.11 b/g/n, 802.1X |
| Security | WPA2-Enterprise (EAP-TLS, EAP-TTLS variants), WPA2-Personal (AES), WPA (TKIP), WEP |
| Cloud Upload Interval | 1 min – 24 h (license-dependent) |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1903 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| IP Rating | IP68 |
| Operating Temperature | -50 °C to +140 °C |
| Accuracy | ±0.1 °C (-40 °C to +140 °C), ±0.2 °C (-50 °C to -40 °C) |
| Resolution | 0.01 °C |
| Response Time (t₉₀) | 6 s |
| Probe Length | 775 mm |
| Probe Diameter | 1.5 mm |
| Probe Tip Diameter | 3 mm |
| Memory Capacity | 60,000 data points |
| Battery Life | 2,500 h (10 s cycle at +121 °C) |
| Housing Dimensions | Ø20 × 63 mm |
| Enclosure Material | Stainless steel + PEEK |
| Battery Type | 1/2 AA lithium |
| Storage Temperature | -20 °C to +50 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-type not applicable — corrected per technical reality) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (testo Ultra-Pixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 °C to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| IFOV | 3.4 mrad |
| Spatial Resolution (Ultra-Pixel mode) | 2.1 mrad |
| Field of View | 31° × 23° |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | 2.8 GB internal memory |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Video Output | USB 2.0 Micro-B streaming |
| Operating Temp. | −15 °C to +50 °C |
| Storage Temp. | −30 °C to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h (Li-ion, rechargeable) |
| Power Supply | AC adapter included |
| Emission Adjustment | 0.01–1.00 (user-selectable) |
| Software | testo IRSoft (Windows 10/8/7, free download) |
| Compliance | EMC Directive 2014/30/EU, RoHS, CE |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8690 11 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C @ 30 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±3 °C or ±3 % of reading (whichever is greater) |
| Field of View | 34° × 26° |
| Minimum Focus Distance | < 0.5 m (fixed focus) |
| IFOV | 3.68 mrad |
| Display | 3.5" LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity Range | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 550 g |
| Battery Life | 4.0 h |
| Internal Memory | 1.6 GB (>2000 images without SuperResolution) |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Software Compatibility | Windows XP SP3 through Windows 10, USB 2.0 interface |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 6:1 |
| Temperature Range | -50 to +300 °C |
| Accuracy | ±1.5 °C (-20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| Measurement Speed | 0.5 s per reading |
| Resolution | 0.1 °C |
| Display | Single-line LCD |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| IP Rating | IP67 (with protective sleeve) |
| Compliance | EN 13485 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB |
| Capacity | Simultaneous programming and readout of up to 8 compatible Testo data loggers |
| Software | Not included — sold separately |
| Brand | testo |
|---|---|
| Origin | Germany |
| Pump Type | Two-Stage Rotary Vane |
| Oil Compatibility | ISO VG 46 |
| Ultimate Vacuum | 15 µm Hg |
| Flow Rate | 283 L/min (10 CFM) |
| Weight | 13 kg |
| Operating Temperature | +5 °C to +40 °C |
| Connection Ports | 1/4", 3/8", and 1/2" SAE |
| Radio Range (Bluetooth 5.0) | 30 m |
| Motor Power | Not specified (industrial-grade AC motor) |
| Refrigerant Compatibility | A2L and A3 classes |
| Compliance | CE, RoHS, UL/cUL listed for refrigeration service environments |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1900 |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Operating Temperature | 0 °C to 140 °C |
| Storage Temperature | −20 °C to +50 °C |
| Housing | Stainless Steel & PEEK |
| IP Rating | IP68 |
| Battery | 1/2 AA Lithium |
| Battery Life | 2,500 h (10 s measurement interval at +121 °C) |
| Memory Capacity | 60,000 values |
| Measurement Interval | 1 s to 24 h |
| Dimensions | Ø22 mm × 83 mm |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-Type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time t₉₉ | 10 s (in water) |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 3164 |
| Detection Sensitivity | <3 g/year (per EN 14624:2012) |
| Detectable Refrigerants | R134a, R22, R404A, H₂, CFCs, HCFCs, HFCs (NH₃ requires optional probe) |
| Operating Temperature | -20 °C to +50 °C |
| Relative Humidity Range | 20–80 % RH |
| Response Time | <1 s |
| Warm-up Time | <50 s |
| Weight | 348 g |
| Dimensions (L×W×H) | 190 × 57 × 42 mm |
| Gooseneck Length | 370 mm |
| Battery | Integrated NiMH pack (6 cells), ~6 h continuous operation |
| Storage Temperature | -25 °C to +70 °C |
| Alarm Type | Visual (LED color shift: green → red) and audible (adjustable tone) |
| Compliance | EN 14624:2012 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1752 |
| Channel Count | Dual-channel (1 built-in + 1 external NTC) |
| Measurement Range (Built-in) | −35 °C to +55 °C |
| Measurement Range (External, via NTC probe) | −40 °C to +120 °C |
| Accuracy (Built-in) | ±0.5 °C (−35 °C to +55 °C), ±1 digit |
| Accuracy (External) | ±0.3 °C (−40 °C to +120 °C), ±1 digit |
| Resolution | 0.1 °C |
| Memory Capacity | 1,000,000 readings |
| Logging Interval | 10 s – 24 h |
| Battery Life | Up to 3 years (15-min interval, +25 °C) |
| Power Supply | 3 × AAA alkaline batteries |
| IP Rating | IP65 |
| Dimensions | 89 × 53 × 27 mm |
| Weight | 130 g |
| Compliance | DIN EN 12830, HACCP-certified, EU EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 4251 |
| Measuring Range (Air Velocity) | 0–20 m/s |
| Measuring Range (Temperature) | –20 to +70 °C |
| Accuracy (Velocity) | ±(0.03 m/s + 5% of reading) |
| Accuracy (NTC Temp) | ±0.5 °C (0–60 °C), ±0.7 °C (remaining range) |
| Resolution (Velocity) | 0.01 m/s |
| Resolution (Temp) | 0.1 °C |
| Telescopic Probe Length | 820 mm |
| Probe Diameter | 7.5 mm |
| Weight | 285 g |
| Dimensions (L×W×H) | 182 × 64 × 40 mm |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –40 to +70 °C |
| Power Supply | 9 V battery |
| Battery Life | ~20 h |
| Housing Material | ABS |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2034 |
| Channel Count | Single-channel |
| Temperature Range | −30 to +50 °C |
| Temp. Accuracy | ±0.5 °C |
| Temp. Resolution | 0.1 °C |
| RH Range | 0 to 100 %RH |
| RH Accuracy | ±2 %RH |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 2 × 10,000 measurements |
| IP Rating | IP30 |
| Dimensions | 115 × 82 × 31 mm |
| Weight | 250 g |
| Power Supply | 4 × AA batteries (typical battery life: 24 months at +25 °C, 15-min interval) |
| Wireless Protocol | Wi-Fi (MQTT), supports WEP/WPA/WPA2/WPA2 Enterprise encryption |
| Time Sync | SNTP-capable |
| Operating Temperature | −30 to +50 °C |
| Storage Temperature (no battery) | −40 to +70 °C |
| Cloud Communication Interval | Basic license: fixed 15 min |
| Advanced license | adjustable from 1 min to 24 h |
| Measurement Interval | Basic: fixed 15 min |
| Advanced | adjustable from 1 min to 24 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3521 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measurable Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 4170 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | +0.3 to +20 m/s |
| Accuracy | ±(0.1 m/s + 1.5 % of reading) |
| Operating Temperature | 0 to +50 °C |
| Operating Humidity | 0 to 95 % RH (non-condensing) |
| Temperature Measurement Range | 0 to +50 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Air Volume Flow Range | 0 to 99,999 m³/h (dependent on duct area or accessory configuration) |
| Weight | 230 g |
| Dimensions | 277 × 105 × 45 mm |
| Housing Material | ABS |
| Power Supply | 9 V battery |
| Battery Life | up to 50 h |
| Storage Temperature | −40 to +70 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8352 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –10 to +1500 °C |
| IR Accuracy | ±2.0 °C or ±1 % of reading |
| Optical Resolution | 50:1 |
| Laser Aiming | 4-point visible laser |
| Emissivity Table | 20 pre-stored values |
| Data Storage | 200 measurements |
| Contact Probe Input | Type K thermocouple (–50 to +1000 °C) |
| Display | Backlit dot-matrix LCD |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Battery | 3 × AA (25 h typical, no backlight/laser) |
| Compliance | EN 61326-1:2006 |