- All
- Favorite
- Popular
- Most rated
| Brand | testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 0563 0890 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Spectral Range | 7.5–14 µm |
| Detector Type | Uncooled Scanning Focal Plane Array (FPA) |
| Thermal Resolution | 640 × 480 pixels |
| NETD | < 40 mK @ 30 °C |
| Frame Rate | 33 Hz |
| Temperature Range | −30 to +100 °C (standard) |
| optional extended ranges | 0 to +350 °C and 0 to +650 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Handheld, battery-powered thermal imaging system |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-type not applicable — corrected per technical reality) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (testo Ultra-Pixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 °C to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| IFOV | 3.4 mrad |
| Spatial Resolution (Ultra-Pixel mode) | 2.1 mrad |
| Field of View | 31° × 23° |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | 2.8 GB internal memory |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Video Output | USB 2.0 Micro-B streaming |
| Operating Temp. | −15 °C to +50 °C |
| Storage Temp. | −30 °C to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h (Li-ion, rechargeable) |
| Power Supply | AC adapter included |
| Emission Adjustment | 0.01–1.00 (user-selectable) |
| Software | testo IRSoft (Windows 10/8/7, free download) |
| Compliance | EMC Directive 2014/30/EU, RoHS, CE |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8690 11 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C @ 30 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±3 °C or ±3 % of reading (whichever is greater) |
| Field of View | 34° × 26° |
| Minimum Focus Distance | < 0.5 m (fixed focus) |
| IFOV | 3.68 mrad |
| Display | 3.5" LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity Range | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 550 g |
| Battery Life | 4.0 h |
| Internal Memory | 1.6 GB (>2000 images without SuperResolution) |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Software Compatibility | Windows XP SP3 through Windows 10, USB 2.0 interface |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8722 |
| Detector Type | Uncooled Microbolometer Focal Plane Array (FPA) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480 pixels) |
| Thermal Sensitivity (NETD) | ≤ 0.06 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading |
| Measurement Method | Non-contact infrared radiometry |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| IFOV | 2.3 mrad (standard lens) |
| Field of View | 42° × 30° |
| Minimum Focus Distance | < 0.5 m |
| Visible Light Camera | ≥ 3.1 MP, autofocus, 3.5″ LCD (320 × 240), brightness-adjustable backlight |
| Digital Zoom | 2× / 4× |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Internal Memory | 2.8 GB |
| Connectivity | Bluetooth 4.2, Wi-Fi 802.11 b/g/n, USB 2.0 Micro-B |
| Wireless Compatibility | testo 605i (humidity/temperature), testo 770-3 (clamp meter) |
| Software | testo IRsoft (Windows 10/8/7), testo Thermography App (iOS/Android) |
| Compliance | EMC Directive 2014/30/EU, Radio Equipment Directive 2014/53/EU |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8712 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 240 × 180 pixels |
| SuperResolution (via testo PixelBoost) | 480 × 360 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.09 °C |
| Field of View | 35° × 26° |
| IFOV | 2.6 mrad (standard), 1.6 mrad (with PixelBoost) |
| Frame Rate | 9 Hz |
| Focus | Fixed-focus lens (min. distance < 0.5 m) |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00, with ε-Assist automatic calibration |
| Reflective Temperature Compensation | RTC-assisted |
| Measurement Modes | Hot/Cold Spot Detection, ΔT, Area Avg, Solar Mode |
| Image Output | IR + visible-light overlay (≥3.1 MP digital camera) |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB (BMT, JPEG, PNG, BMP, CSV, XLS) |
| Connectivity | Bluetooth 4.2 + Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 Micro-B |
| Environmental Rating | IP54 |
| Operating Temp. | −15 to +50 °C |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Compliance | RED Directive 2014/53/EU, EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 8832 |
| Detector Type | Uncooled Scanning Focal Plane Array (FPA) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480) |
| Thermal Sensitivity (NETD) | < 0.04 °C |
| Field of View | 30° × 23° (standard lens), 12° × 9° (telephoto lens) |
| Spatial Resolution (IFOV) | 1.7 mrad (standard), 0.7 mrad (telephoto) |
| SuperResolution IFOV | 1.1 mrad / 0.4 mrad |
| Frame Rate | 27 Hz (EU-compliant |
| Temperature Range | –30 °C to +650 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Focus | Manual |
| Measurement Method | Non-contact infrared radiometry |
| Operating Temperature | –15 °C to +50 °C |
| Storage Temperature | –30 °C to +60 °C |
| IP Rating | IP54 |
| Battery Life | ≥ 5 hours |
| Weight | 824 g |
| Dimensions | 171 × 95 × 236 mm |
| Display | 3.5" capacitive touch TFT (320 × 240 QVGA), adjustable backlight |
| Image Formats | .bmt, .jpg, .png, .csv, .xls |
| Data Interface | USB-C, Bluetooth 5.0, WLAN (optional module) |
| Software | testo IRSoft (free PC software), testo Thermography App (iOS/Android) |
| Compliance | RED 2014/53/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS 2011/65/EU + 2015/863, REACH 1907/2006 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8681 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (via testo SuperPixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.10 °C |
| Field of View (FOV) | 31° × 23° |
| Instantaneous Field of View (IFOV) | 3.4 mrad (standard lens) |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00 (with ε-Assist automatic calibration) |
| Reflected Apparent Temperature Compensation | Yes (RTC-assisted) |
| Focus | Fixed-focus optimized for ≥0.5 m |
| Visible Light Camera | ≥3.1 MP, co-registered with IR |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Environmental Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 510 g |
| Dimensions | 219 × 96 × 95 mm |
| Compliance | EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8832 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480) |
| Thermal Sensitivity (NETD) | < 0.04 °C |
| Temperature Range | −30 to +650 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Field of View (Standard Lens) | 30° × 23° |
| IFOV (Standard Lens) | 1.7 mrad |
| Minimum Focus Distance | < 0.1 m |
| Frame Rate | 27 Hz (EU-compliant |
| Display | 3.5" capacitive touchscreen (QVGA, 320 × 240) |
| Image Storage | Internal 2.8 GB memory (.bmt, .jpg, .png, .csv, .xls export) |
| Battery Life | ≥ 5 h |
| IP Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 824 g |
| Compliance | RED 2014/53/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS 2011/65/EU + 2015/863, REACH 1907/2006 |