- All
- Favorite
- Popular
- Most rated
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | testo 830-T4 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Laser Aiming | Dual-point |
| Measurement Frequency | 2 Hz |
| IR Temperature Range | –30 to +400 °C |
| IR Accuracy | ±1.5 °C (–20 to 0 °C), ±2 °C (–30 to –20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| Response Time (IR) | 0.5 s |
| Contact Probe Input | Type K thermocouple (–50 to +500 °C, ±0.5 °C + 0.5 %, resolution 0.1 °C, response time 1.75 s) |
| Display | Backlit LCD |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 6:1 |
| Temperature Range | -50 to +300 °C |
| Accuracy | ±1.5 °C (-20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| Measurement Speed | 0.5 s per reading |
| Resolution | 0.1 °C |
| Display | Single-line LCD |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| IP Rating | IP67 (with protective sleeve) |
| Compliance | EN 13485 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8352 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –10 to +1500 °C |
| IR Accuracy | ±2.0 °C or ±1 % of reading |
| Optical Resolution | 50:1 |
| Laser Aiming | 4-point visible laser |
| Emissivity Table | 20 pre-stored values |
| Data Storage | 200 measurements |
| Contact Probe Input | Type K thermocouple (–50 to +1000 °C) |
| Display | Backlit dot-matrix LCD |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Battery | 3 × AA (25 h typical, no backlight/laser) |
| Compliance | EN 61326-1:2006 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T4 |
| Instrument Type | Portable |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IR Temperature Range | −50 to +300 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Probe Range | −50 to +230 °C |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Measurement Speed | 0.5 s |
| NTC Measurement Speed | 1.25 s |
| Resolution | 0.1 °C (both modes) |
| Display | Single-line LCD |
| IP Rating | IP67 (with protective sleeve) |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Compliance | EN 13485, HACCP-ready |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 810 |
| Type | Portable Infrared Thermometer |
| Infrared Temperature Range | -30 to +300 °C |
| Air Temperature Range (NTC) | -10 to +50 °C |
| IR Accuracy | ±2.0 °C (-30 to +100 °C), ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C |
| Optical Resolution | 6:1 |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Display | Backlit LCD with ΔT calculation |
| Laser Targeting | Single-point |
| IP Rating | IP40 |
| Weight | 90 g (incl. batteries and protective sleeve) |
| Dimensions | 119 × 46 × 25 mm (with sleeve) |
| Operating Temperature | -10 to +50 °C |
| Battery | 2 × AAA, ~50 h life (backlight off) |
| Response Time | 0.5 s (both channels) |
| Resolution | 0.1 °C (both IR and NTC) |
| Data Functions | Max/Min/Hold |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Portable Infrared Thermometer |
| Temperature Range | -30 to +400 °C |
| Accuracy | ±1.5 °C or ±1.5 % of reading (0.1 to +400 °C) |
| Optical Resolution | 10:1 |
| Response Time | 0.5 s |
| Resolution | 0.1 °C |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Measurement Frequency | 2 Hz |
| Display | Backlit LCD with Max/Min/Hold functions |
| Alarm | Dual user-defined limit thresholds with audible and visual alert |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Housing Material | ABS |
| Power Supply | 9 V alkaline battery |
| Battery Life | Approx. 15 hours |
| Brand | testo |
|---|---|
| Model | 830-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 12:1 |
| Laser Targeting | Dual-point |
| Emissivity Adjustment | Yes |
| Temperature Range (IR) | –30 °C to +400 °C |
| Temperature Range (Contact Probe) | –50 °C to +500 °C |
| IR Accuracy | ±1.5 °C or ±1.5 % of reading (whichever is greater) from 0.1 °C to 400 °C |
| Contact Probe Accuracy | ±0.5 °C + 0.5 % of reading |
| IR Resolution | 0.1 °C |
| Contact Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Response Time | 1.75 s |
| Probe Type | K-type (NiCr–Ni) thermocouple |
| Display | Backlit LCD |
| Alarm Function | Dual user-defined high/low limits with audible and visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Housing Material | ABS |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | –20 °C to +50 °C |
| Storage Temperature | –40 °C to +70 °C |
| Power Supply | 9 V battery (included) |
| Battery Life | ~15 hours |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 830-S1 |
| Type | Portable Infrared Thermometer |
| Housing Material | Anodized Aluminum |
| Laser Targeting | Single-Point |
| Alarm Function | Adjustable Upper/Lower Limit with Audible Alert |
| Measurement Principle | Non-Contact Infrared Pyrometry (8–14 µm Spectral Range) |
| Emissivity Adjustment | Fixed at 0.95 (optimized for common industrial surfaces) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Limit | ≤95 % RH (non-condensing) |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 10 hours continuous use |
| Display | Backlit LCD with hold function |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 0563 8314 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| IR Temperature Range | -30 to +400 °C |
| IR Accuracy | ±1.5 °C (-20 to 0 °C), ±2 °C (-30 to -20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Probe Type | Spring-loaded surface probe (Type K thermocouple, 0602 0393) |
| Contact Range | -50 to +500 °C |
| Contact Accuracy | ±0.5 °C + 0.5 % of reading |
| Contact Resolution | 0.1 °C |
| Contact Response Time | 1.75 s |
| Display | Backlit LCD |
| Laser Aiming | Dual-point |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Alarm Function | Two user-defined limits with audible/visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Dimensions | 190 × 75 × 38 mm |
| Weight | 200 g |
| Power Supply | 9 V battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8351 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –30 to +600 °C |
| IR Accuracy | ±2.5 °C (–30.0 to –20.1 °C), ±1.5 °C (–20.0 to –0.1 °C), ±1.0 °C (0.0 to +99.9 °C), ±1 % of reading (remaining range) |
| Optical Resolution | 50:1 |
| Emissivity Adjustment | 0.10–1.00 (20 preset values stored) |
| Contact Temperature Input | Type K thermocouple (–50 to +600 °C, ±0.5 °C + 0.5 % of reading) |
| Display | Backlit dot-matrix LCD |
| Data Storage | 200 measurement values |
| Interface | USB for PC connectivity |
| Power | 3 × AA batteries (25 h typical runtime, laser & backlight off) |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –30 to +50 °C |
| Compliance | EN 61326-1:2006 (EMC), CE-marked |
Show next