| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Netherlands |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Quattro |
| Configuration | Floor-standing (Conventional High-Performance SEM) |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Vacuum Modes | High Vacuum / Low Vacuum / Environmental SEM (ESEM™) |
| Detector Compatibility | In-lens SE, Solid-state BSE, STEM-in-SEM, Cathodoluminescence (CL), EDS (up to 3 detectors), EBSD, WDS |
| Stage | Motorized 5-axis eucentric stage with ±105° tilt |
| Temperature Range (In-situ) | –165°C to 1400°C (with optional cryo/thermal stages) |
| Software Platform | Thermo Scientific™ Avizo™-integrated SmartSEM™ with Python-based AutoScript API |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Apreo ChemiSEM |
| Quotation | Upon Request |
| Instrument Form Factor | Floor-Standing |
| Electron Source Type | Thermal Field-Emission Gun (TFEG) |
| Microscope Class | Ultra-High-Resolution Field-Emission SEM |
| Secondary Electron Resolution | 0.7 nm @ 30 kV |
| Magnification Range | 29× to 200,000× |
| Accelerating Voltage Range | 200 V – 30 kV |
| Backscattered Electron Resolution | 0.8 nm @ 1 kV |
| Brand | Thermo Fisher |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Axia ChemiSEM |
| Instrument Type | Floor-Standing Conventional SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3 nm @ 30 kV, 8 nm @ 3 kV |
| Accelerating Voltage | 0.2–30 kV |
| Backscattered Electron Imaging Capability | Integrated |
| Elemental Analysis Integration | On-platform EDS (Energy-Dispersive X-ray Spectroscopy) |
| Sample Weight Capacity | Up to 10 kg |
| Automation Level | Fully Automated Beam Alignment, Smart User Guidance, Undo Functionality |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Volumescope 2 |
| Instrument Type | Floor-standing SEM |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Accelerating Voltage | 1.0–30 kV |
| Vacuum Modes | High Vacuum (HiVac) and Low Vacuum (LoVac) with VSDBS detector |
| Z-axis Optical Sectioning Resolution | Up to 10 nm |
| Sample Handling | Automated ultramicrotome integration for seamless transition between conventional SEM and SBFI/AT workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Production |
| Model | Apreo |
| Instrument Type | Floor-Model High-Performance SEM |
| Electron Gun Type | Cold Field Emission (CFEG) |
| Microscope Class | Ultra-High-Resolution Field-Emission SEM |
| Secondary Electron Resolution | 1.0 nm at 1 kV (in-lens detection, no beam deceleration or monochromator) |
| Accelerating Voltage Range | 200 V – 30 kV |
| Backscattered Electron Resolution | ≤1.5 nm at 30 kV (T1 in-lens BSE detector) |
| Chamber Configuration | Triple EDS/WDS port capability |
| Vacuum System | Dual-mode (High Vacuum & Variable Pressure up to 500 Pa) |
| Software Platform | xT User Interface with SmartSCAN™, Drift Compensation Frame Integration (DCFI), and Charge Filtering Algorithms |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Electron Gun Type | Cold Field Emission |
| Model | Prisma E SEM |
| Vacuum Modes | High Vacuum, Low Vacuum, Environmental SEM (ESEM) Mode |
| Sample Chamber Capacity | Up to 18 samples per load |
| Detector Flexibility | Multiple detector options including SE, BSE, EDS, and optional STEM-in-SEM |
| Software Integration | ColorSEM real-time elemental mapping, image navigation, customizable UI with Undo/Redo functionality |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Verios XHR |
| Instrument Type | Floor-standing / Conventional High-Performance SEM |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Accelerating Voltage Range | 1–30 kV |
| Secondary Electron Resolution | <0.7 nm at 1 kV, <0.4 nm at 30 kV (as specified in Thermo Fisher technical documentation) |
| Backscattered Electron Resolution | <1.5 nm at 30 kV |
| Sample Chamber Dimensions | Ø340 mm × H280 mm |
| Maximum Sample Size | 200 mm wafer or 100 mm × 100 mm × 50 mm bulk specimen |
Show next