- All
- Favorite
- Popular
- Most rated
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Model 300S |
| Detection Principle | Evaporative Light Scattering |
| Compatible Systems | HPLC (Analytical & Preparative) |
| Wavelength Range | 195–600 nm |
| Optical Configuration | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Light Source for Detection | 650 nm Near-Infrared Laser (<5 mW, FCC Class I Eye-Safe) |
| Detector Element | Sealed, Large-Area Silicon Photodiode with Integrated High-Gain Amplifier |
| Minimum Detectable Mass | 100 pg Glucopyranoside (Micro-HPLC, 2 µL direct injection, peak width at 10% height: 3 s) |
| Dynamic Range (Normal Gain) | 3 decades |
| Dynamic Range (Extended Mode) | 4–4.5 decades |
| Mobile Phase Flow Rate Compatibility | Up to 5 mL/min |
| Carrier Gas | Nitrogen or other inert gas |
| Gas Pressure Requirement | 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Integrated Gas Pressure Regulation | Yes (Built-in Regulator & Overpressure Protection) |
| Auto Shut-off Valve | Yes (Timed Delay Cutoff) |
| Fluidic Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass (Optical Lens) |
| User Interface | Vacuum Fluorescent Display (VFD) + 4 Multifunction Keys |
| Onboard Method Storage | 10 Methods |
| Signal Output Options | Fixed 10 mV / 5 V |
| Communication Interface | RS-232 (Rear Panel) |
| Power Supply | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | VICI |
|---|---|
| Model | PS-050025 |
| Volume | 100 µL |
| Needle | RN (Removable Needle), Bevel Tip, 0.029" OD × 0.005" ID × 2" L |
| Maximum Pressure Rating | 250 psi |
| Seal Material | PTFE Plunger Tip & Needle Seal |
| Barrel Material | Glass |
| Valve Type | Integrated Push-Button Actuated On/Off Valve |
| Compliance | Designed for GLP/GMP-compliant chromatographic workflows requiring trace-level sample integrity |
| Brand | CoMetro |
|---|---|
| Model | 6000LDS |
| Flow Rate | 0.001–80 mL/min (selectable ranges) |
| Maximum Pressure | 6000 psi (stainless steel pump head), 5000 psi (PEEK pump head) |
| Pressure Accuracy | ±1% |
| Flow Precision | ≤0.2% RSD |
| Display | Real-time flow rate, system pressure, upper/lower pressure limits |
| Control Interface | Front-panel keypad + RS232 digital communication |
| Power Supply | 115/230 V, 50/60 Hz |
| Fluid Path Materials | Optional PEEK or 316 stainless steel |
| Integrated Features | Low-dead-volume pulsation dampener, fast-fill priming mechanism, passive check valves, built-in bypass valve, self-cleaning module |
| Brand | CoMetro |
|---|---|
| Model | CPT |
| Pump Type | Binary HPLC Pump |
| Max Pressure | 6000 psi (42 MPa) |
| Flow Rate Range | 0.001–5 mL/min |
| Temperature Control Range | +10°C to 120°C above ambient |
| Temperature Accuracy | ±0.5°C |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Wetted Materials | 316L Stainless Steel |
| Interface | RS232, Analog Voltage/Frequency Input |
| Power Supply | 220 V, 50 Hz |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 PCR |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Brand | SSI |
|---|---|
| Flow Rate | 0.001–5 mL/min / 0.01–10 mL/min / 0.1–40 mL/min |
| Maximum Pressure | 6000 psi (316 SS) / 5000 psi (PEEK) |
| Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Pulse Damping | Integrated low-dead-volume pulsation damper |
| Auto-Cleaning | On-column seal rinse with programmable solvent flush |
| Materials | 316 stainless steel or PEEK (biocompatible) |
| Communication | RS232 digital interface |
| Power | 115/230 V, 50/60 Hz |
| Dimensions | 140 H × 254 W × 432 D mm |
| Weight | 11 kg |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CP-LDI |
| Flow Rate Options | 0.001–12 mL/min, 0.01–24 mL/min, 0.1–100 mL/min, 0.1–200 mL/min |
| Max Pressure | Up to 6000 psi (414 bar) — model-dependent |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Pump Head Configuration | Parallel dual-piston |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201H |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.25–512 μRIU |
| Drift | ≤0.2 μRIU/h (deionized water, 1 mL/min, purge off) |
| Linearity | ≥600 μRIU |
| Noise | ≤2.5 nRIU (deionized water, 1.5 s response) |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero | Full-range automatic zeroing |
| Offset Adjustment Range | ±10 μRIU |
| Offset Resolution | 50 nRIU |
| Cell Volume | 8 µL |
| Flow Rate Range | 0.2–3.0 mL/min (typical), up to 10 mL/min (water) |
| Max Backpressure | 50 kPa |
| Internal Dead Volume | IN→Cell ≈60 µL |
| Temperature Control | OFF, 30–55 °C (1 °C increments), 77 °C thermal cutoff |
| Interface | USB |
| Wetted Materials | SS316, PTFE, fused silica |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Isocratic (Single-Solvent) High-Pressure Liquid Chromatography Pump |
| Maximum Pressure | 6000 psi (standard), up to 10,000 psi (customizable) |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.1% RSD |
| Pump Head Configuration | Dual parallel piston heads |
| Wetted Materials | SS316L and PEEK options available |
| Compliance | Designed for GLP/GMP-aligned workflows and compatible with USP <1058> analytical instrument qualification practices |
| Brand | Scienhome |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WSE |
| Automation Level | Semi-Automatic |
| Number of Channels | Multi-Channel (4 Parallel Sample Positions) |
| Extraction Mode | Dispersive SPE (dSPE) |
| Flow Rate Control | Up to 30 mL/min |
| Solvent Selection Ports | 5 Independent Solvent Lines |
| Maximum Sample Volume per Channel | 30 mL |
| Wetted Materials | Chemically Resistant PTFE, Borosilicate Glass, and SPE-Compatible Polymers |
| Compliance | Designed for GLP-compliant workflows in regulated laboratories |
| Brand | CoMetro |
|---|---|
| Model | R1 / R2 |
| Type | Programmable Volume-Based Fraction Collector |
| Collection Modes | Time-, Drop-, Volume-, and Peak-Triggered |
| Max Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, excl. rack) | 7.7 kg |
| Weight (R2, excl. rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Capacity Options | 36–144 positions (1.5 mL to 50 mL tubes, vials, or custom vessels) |
| Compliance | CE-marked, designed for GLP-compliant laboratory environments |
| Brand | SSI |
|---|---|
| Origin | Imported |
| Model | SFC-24 |
| Max Flow Rate | 24 mL/min |
| Max Pressure | 10,000 psi |
| Pressure Accuracy | ±2% of full scale |
| Flow Accuracy | ±5% (gas-volume-based liquid flow calculation) |
| Cooling | Integrated Peltier thermoelectric module |
| Construction | Aluminum pump head, stainless steel fluid path |
| Control Interface | Front-panel keypad with LED display, RS-232 remote control |
| Dimensions | 146 H × 283 W × 537 D mm |
| Weight | 16 kg |
| Brand | SSI |
|---|---|
| Model | Series III |
| Flow Rate | 0.1–40 mL/min |
| Maximum Pressure | 1500 psi |
| Accuracy | ±2% |
| Flow Precision | 0.2% RSD |
| Pressure Monitoring | Integrated Sensor with LED Display |
| Pulse Damping | Miniature Diaphragm-Type |
| Self-Cleaning Pump Head | Onboard Actuation |
| Control Interface | Digital Logic Circuit + Stepper Motor |
| Remote Inputs | Frequency & Voltage Analog, RS232 Serial |
| Wetted Materials | PEEK or 316L Stainless Steel |
| Dimensions | 140 H × 254 W × 432 D mm |
| Weight | 11 kg |
| Power | 115/230 V, 50/60 Hz |
| Brand | Scienhome |
|---|---|
| Origin | Tianjin, China |
| Model | AP-01P |
| Filter Capacity | 300 mL (funnel), 1 L / 2 L (receiving flask) |
| Construction | Borosilicate glass (up to 270 °C thermal shock resistance) |
| Vacuum Source | Oil-free diaphragm pump |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with USP <788> particulate matter testing and ASTM E2904-21 for solvent clarity validation |
| Accessories | Sintered glass frit (porosity: G3/G4), sealing O-rings, clamp assembly, vacuum tubing kit |
| Operating Pressure Range | 0.05–0.08 MPa (absolute), typical working vacuum: −85 to −95 kPa |
| Brand | SSI |
|---|---|
| Model | Series II |
| Flow Range | 0.001–5 mL/min, 0.01–10 mL/min, or 0.1–40 mL/min |
| Maximum Pressure | 6000 psi (316 stainless steel), 5000 psi (PEEK), 1500 psi (low-pressure configuration) |
| Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Pulse Damping | Integrated low-dead-volume pulsation damper |
| Auto-Cleaning System | On-column solvent-driven self-cleaning module with weekly aqueous solution refresh |
| Seal Replacement | Tool-free, <5-minute procedure |
| Flow Path Materials | Selectable 316 stainless steel or PEEK (biocompatible) |
| Remote Control Interface | Analog voltage input, frequency input, RS232 serial communication |
| Dimensions | 140 H × 254 W × 432 D mm |
| Weight | 11 kg |
| Power Supply | 115 V / 230 V, 50 / 60 Hz |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Time-based, Drop-count-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12/13 mm diameter) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Input | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Construction | Anodized aluminum frame and stainless steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | SSI |
|---|---|
| Origin | Imported |
| Model | BLS CLASS |
| Flow Rate | 0.000–10.00 mL/min (up to 6,000 psi) |
| Pressure Rating | 6,000 psi (stainless steel/PEEK fluid path), 5,000 psi (PEEK-only configuration) |
| Pulsation | ≤2% at 1 mL/min and 1,000 psi (with pulse dampener) |
| Flow Accuracy | <±2% of full scale (≥0.20 mL/min, 20% IPA/water, 1,000 psi) |
| Flow Precision | ≤0.2% RSD |
| Fluid Path Materials | Stainless steel, PEEK, optional titanium |
| Dimensions | 22.9 cm H × 25.4 cm W × 43.2 cm D |
| Weight | 13.6 kg |
| Power Input | 100–240 VAC ±10%, 50–60 Hz |
| Control Interfaces | RS-232, Micro-USB, analog (0–10 V / 4–20 mA), discrete Run/Stop |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000PER Photochemical Derivatization Unit |
| Light Source | Cold UV LED |
| Output Power | 8 mW |
| Wavelength | 254 nm |
| Maximum Flow Rate | 3 mL/min |
| Reaction Chamber | Köhler Illumination Design |
| Temperature Control | Forced-Air Cooling |
| Operating Temperature Range | Up to 100 °C |
| Derivatization Type | Post-Column, Reagent-Free Photochemical Activation |
| Brand | CoMetro |
|---|---|
| Model | CP-M |
| Flow Rate | 10 mL/min |
| Maximum Pressure | 6000 psi |
| Accuracy | ±2% |
| Precision (RSD) | 0.2% |
| Dimensions | 175(H) × 225(W) × 305(D) mm |
| Weight | 11 kg |
| Power Supply | 230 V / 115 V, 50 / 60 Hz |
| Fluid Path Materials | PEEK or 316 Stainless Steel |
| Control Interface | Keypad and RS232 digital communication |
| Pressure Sensing | Non-contact electronic transducer |
| Brand | SSI |
|---|---|
| Model | Series II |
| Type | Single-Piston High-Performance Solvent Delivery Pump |
| Flow Range | 0.001–5 mL/min, 0.01–10 mL/min, or 0.1–40 mL/min |
| Maximum Pressure | 6000 psi (316 SS), 5000 psi (PEEK), 1500 psi (low-pressure configuration) |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Pulsation Damping | Integrated low-dead-volume pulsation damper |
| Auto-Cleaning System | On-column solvent-driven self-cleaning mechanism with weekly aqueous solution refresh |
| Seal Replacement | Tool-free, <5-minute procedure |
| Prime/Flush Function | One-touch automated priming, flushing, and degassing |
| Fluidic Path Materials | Selectable 316 stainless steel or biocompatible PEEK |
| Communication Interface | RS232 digital output, analog voltage/frequency input |
| Power Supply | 115 V / 230 V, 50 / 60 Hz |
| Dimensions (H×W×D) | 140 × 254 × 432 mm |
| Weight | 11 kg |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Isocratic Pump |
| Max Pressure | 6000 psi |
| Flow Rate Range | 0.001–12 mL/min |
| Pump Head Configuration | Parallel Dual-Head |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.1% RSD |
| Pressure Units | psi, MPa, bar |
| Control Modes | Front-panel keypad, RS-232/USB PC interface, analog input (0–5 V / 4–20 mA) |
| Compressibility Compensation | Adjustable |
| Auto-Purge & Solvent Flush | Supported |
| Optional Multi-Pump Gradient Expansion | Up to 4 units |
| Brand | Eldex |
|---|---|
| Model | 1LM |
| Flow Rate | 0.002–2.5 mL/min (1LM), 0.02–40 mL/min (2HM) |
| Maximum Pressure | 414 bar (1LM), 103 bar (2HM) |
| Viscosity Range | Up to 500 cP |
| Temperature Range | Up to 120 °C |
| Repeatability | ±0.3% |
| Inlet/Outlet | 1/8" Swagelok (1HM, 2HM, 3HM) |
| Power Supply | 100–230 VAC, 50/60 Hz, 80 W |
| Dimensions (W×H×D) | 10 × 23 × 24 cm |
| Weight | 5.3 kg (standard), 6.4 kg (pulse-damped version) |
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201 |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | HPLC |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.125–256 µRIU |
| Drift | ≤0.1 µRIU/h |
| Noise | ≤1 nRIU |
| Linear Range | ≥300 µRIU |
| Flow Rate (Typical) | 0.2–3.0 mL/min |
| Max Flow Rate (Water) | 10 mL/min |
| Cell Volume | 8 µL |
| Dead Volume (IN→Cell) | ~80 µL |
| Dead Volume (Cell→OUT) | ~600 µL |
| Total Dead Volume | ~690 µL |
| Temperature Control Range | 30–55 °C (1 °C increments), with dual-stage thermal regulation |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero Function | Full-range, fully automatic |
| Offset Adjustment Range | ±5 µRIU |
| Offset Resolution | 25 nRIU |
| Analog Output | DC 0–1 V (4 mV/µRIU or 16 mV/µRIU selectable) |
| Recorder Output | 0–10 mV/FS |
| Communication Interface | USB |
| Wetted Materials | SUS316 Stainless Steel, PTFE, Quartz Glass |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | Full PEEK |
Show next