BrandSipo Environment
OriginTianjin, China
ModelBODAuto™1000
Instrument TypeLaboratory BOD Analyzer
PrincipleDissolved Oxygen (DO) Depletion Method (Standard 5-day Incubation)
Measurement Range2–6000 mg/L
Detection Limit< 0.5 mg/L
Accuracy±0.1 mg/L (for 0–20 mg/L range)
Single-Sample Measurement Time< 30 s (at 25°C, 90% response)
Repeatability< 0.1 mg/L
Sample Capacity18 positions
DO ElectrodeImported German electrochemical sensor (0–20.00 mg/L, 0–200.0 % saturation
resolution0.01 mg/L / 0.1 %)
Temperature Compensation0–45 °C
Salinity Compensation0–45 ppt
Barometric Pressure Compensation80–105 kPa
Peristaltic Pump Flow Rate1.2 L/min
Incubation Vessel300 mL borosilicate glass bottle with water-seal PVC cap
Positioning Accuracy< 0.1 mm (Hall-effect servo feedback)
Motor SystemMOONS (Japan) stepper-servo motors
Power SupplyAC 220 V, 50 Hz
Power Consumption350 W
Dimensions (W×D×H)1000 × 420 × 500 mm
WeightApprox. 48 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelBOD-220A-2
Instrument TypePortable BOD Analyzer
Measurement PrincipleMicrobial Membrane Electrode Method
Measuring Range2–4000 mg/L
Sample Measurement Time8 min
RSD≤5%
Temperature Control Accuracy±0.1°C
Power SupplyAC 110–220 V / DC 12 V (automotive cigarette lighter compatible)
Dimensions260 × 400 × 180 mm
Weight~12 kg
Power Consumption<50 W
Operating Ambient Temperature5–40°C
Sensor ConfigurationIntegrated 3-electrode microbial sensor with reference electrode (Patent ZL 00 257536.1)
Incubation SystemReflective thermostatic chamber with heating/cooling (Patent ZL 01 267798.1)
Microbial MembraneDry-layer immobilized BOD₅-specific strain (InterBio™, EPA-certified)
Membrane Shelf Life>12 months (dry storage at room temperature)
Sample Volume Required>20 mL
Buffer Consumption150 mL/h
Data Storage Capacity99 test records
InterfaceExternal thermal mini-printer support
Inlet ModePeristaltic pump-driven continuous flow
HousingLightweight extruded aluminum frame with shock-absorbing mounting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnviron Lab
OriginUSA
ModelBODTECH-8
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleMercury-Free Pressure-Based Dissolved Oxygen Consumption Detection (Piezoelectric Crystal Sensor)
Measurement Range0–4000 mg/L (extendable to 5000 mg/L)
Accuracy±1 mg/L (±3.55 hPa)
Operating Pressure Range500–1100 hPa
Temperature CompensationAutomatic, Real-Time
Stirring Speed180–450 rpm
IP RatingIP54
Ambient Operating Temperature+5°C to +50°C
Power SupplyButton-Cell Lithium Battery
Max Concurrent Samples4 × n (modular 4-bottle units)
Display2-Digit 7-Segment LED
Sample HandlingUndiluted, Direct Measurement
Stirring ConfigurationElectromagnetic, Continuous
Data LoggingDaily Automated BOD Value Capture and Storage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSPN-BOD-220A
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleMicrobial Electrode Method
Measurement Range2–4000 mg/L
Detection Limit0.5 mg/L
Accuracy±1 mg/L
Single-Sample Analysis Time8 min
Repeatability≤3%
Power SupplyAC 220 V ±10%, 50 Hz
Operating Temperature10–35 °C
Humidity Range30–85% RH (non-condensing)
Dimensions (W×D×H)420 × 380 × 260 mm
Weight12.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelBODAuto™2200
BOD₅ Measurement Range2–6000 mg/L
Detection Limit< 0.5 mg/L
Accuracy±0.1 mg/L (0–20 mg/L)
Single-Sample Measurement Time< 30 s (at 25 °C, 90% response)
Repeatability< 0.1 mg/L
DO Electrode Range0–20.00 mg/L (ppm) / 0–200.0 % saturation
DO Resolution0.01 mg/L / 0.1 %
Response Time (DO)≤30 s (25 °C, 90% response)
Temperature Compensation0–45 °C
Salinity Compensation0–45 ppt
Barometric Pressure Compensation80–105 kPa
Peristaltic Pump Flow Rate1.2 L/min
Syringe Pump Volume Range0–100 mL
Syringe Pump Accuracy±0.3 %
Sample Vial Capacity300 mL
Sample Tray Configuration3 × 6 positions (18 per tray), total 54 positions
Positioning Accuracy< 0.1 mm (Hall-effect sensor-based servo control)
Power SupplyAC 220 V, 50 Hz
Host Power Consumption350 W
Dimensions (W×D×H)1500 × 650 × 650 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelBODAuto-2100
Instrument TypeLaboratory BOD Analyzer
PrincipleDissolved Oxygen (DO) Method (5-Day Incubation)
Measurement Range2–6000 mg/L
Detection Limit0.1 mg/L
Accuracy±5%
Single-Sample Measurement Time<60 s
Reproducibility±0.1 mg/L (per 54-bottle batch)
DO Electrode Range0–20.00 mg/L
DO Resolution0.01 mg/L
DO Response Time≤30 s (90% at 25 °C)
Temperature CompensationAutomatic (0–45 °C)
Salinity CompensationAutomatic (0–45 ppt)
Barometric Pressure CompensationAutomatic (80–105 kPa)
Sample Capacity54 positions per tray, modular multi-tray support
Power SupplyAC 220 V, 50 Hz, 350 W
Dimensions1500 × 650 × 650 mm
Operating Environment5–45 °C, non-corrosive atmosphere
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelBOD-220B Main Unit
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleFlow-through Microbial Electrode Method
Measurement Range2–4000 mg/L
Detection Limit2–4000 mg/L
Accuracy≤3%
Single-sample Analysis Time8 min
Repeatability±2%
Sensor ConfigurationIntegrated Triple-electrode Sensor with Reference Electrode
Sample Volume Requirement>40 mL
Temperature Control Precision±0.1°C
Buffer Consumption270 mL/h
Dimensions540 × 370 × 225 mm
Weight~18 kg
Power SupplyAC 220 V, 50 Hz
Communication InterfaceRS-232 (expandable for automated sampler integration)
Data Storage Capacity99 test records
Built-in Thermal PrinterYes
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeDistributor
Origin CategoryImported
ModelBioMonitor
Instrument TypeOnline BOD Analyzer
Measurement PrincipleDissolved Oxygen (DO)-Based Respirometric Method
Measurement Range1–50 mg/L and 1–200,000 mg/L BOD
Detection Limit1 mg/L
Accuracy±2% of reading within both ranges
Sample Interval3–4 minutes per measurement
Repeatability±2% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelBOD-220B
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleMicrobial Membrane Electrode Method
Measurement Range2–4000 mg/L
Detection Limit2 mg/L
Accuracy≤3%
Single-Sample Analysis Time8 min
Repeatability±2%
Sensor ConfigurationIntegrated Three-Electrode Sensor with Reference Electrode (Patent No.: ZL 00 257536.1)
Signal Output0–20 µA
Flow-Through Cell DesignCombined Flow Cell and Measurement Chamber
Microbial StrainEPA-certified InterBio BOD₅-specific strain
Membrane FormatDry-layer sandwich membrane, non-toxic and biocompatible
Membrane Shelf Life>12 months under ambient dry storage
Sample IntroductionFully automated via optional 24-position autosampler
Control SystemPC-based microprocessor control
Software PlatformWindows 95/98/2000/XP (localized Chinese GUI)
Operation ModesManual or fully automated sequential/jump sampling
Data HandlingAutomatic archival to internal database
Positioning SystemTriple-redundant mechanical, electromagnetic, and optical sample positioning
Sample Vial Capacity24 × 50 mL standard cups
Power ManagementScheduled auto-shutdown and electrode sleep mode for membrane preservation