Tianjin Sepu Environmental Protection Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOilTech221
Instrument TypePortable
Measurement PrincipleUV Absorption Spectrophotometry at 225 nm
Measurement Range0–60 mg/L
Detection Limit0.01 mg/L
Accuracy±2%
Resolution1 nm
WavelengthFixed 225 nm monochromatic
Light SourceDFB semiconductor laser (225 nm)
DetectorMSM photodetector
Stray Light≤0.1% T
Baseline Stability±0.002 A/h
Calibration OptionsSingle-point, multi-point (1–6 points), certified reference material-based
Preloaded Calibration Curves≥10
Extraction UnitHandheld, 3-speed adjustable
FiltrationDisposable magnesium silicate cartridge
PowerDual rechargeable Li-ion batteries, 8 h continuous operation
Display5.5-inch capacitive touchscreen
Data ExportUSB interface
ComplianceHJ 970–2018 (China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOIL-UV-2100
Measurement PrincipleUV Spectrophotometry
Measurement Range0–80 mg/L
Detection Limit0.005 mg/L
Accuracy<2%
Wavelength Resolution1 nm
Sample Measurement Time15 s per sample
Wavelength Range190–1100 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability0.2 nm
Spectral Bandwidth2 nm
Absorbance Range−0.30 to 3.0 A
Absorbance Repeatability (RSD)≤1%
Correlation CoefficientR > 0.999
Transmittance Accuracy±0.3% T
Stray Light≤0.2% T
Baseline Drift±0.002 A/h
Extraction Methodn-Hexane Extraction (Compliant with HJ 970–2018)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOIL-IR-2100
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Absorption Spectrophotometry (Triple-Wavelength Method)
Measurement Range0–800 mg/L
Detection Limit0.02 mg/L
Accuracy<1% RSD
Spectral Resolution1 cm⁻¹
Scan SpeedFull-spectrum scan in 30 s
Operating SystemEmbedded Windows 10 (10.0-inch touchscreen tablet)
ConnectivityBluetooth 4.2, USB 3.0, RS-232/RS-485
Optical SourceElectrically Modulated IR Source (Lifespan ≥5000 h)
Housing MaterialABS with EMI shielding, impact-resistant and corrosion-resistant finish
Baseline StabilityReal-time zero-point auto-adjustment (dual-signal acquisition: light-on & light-off)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOIL-IR-BX
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry
Measurement Range0–150 mg/L
Detection Limit0.02 mg/L
Accuracy< ±1%
Spectral Resolution1 cm⁻¹
Full-Spectrum Scan Time30 s per sample
RepeatabilityRSD ≤ 1% (20–100 mg/L oil standard, n = 11)
Correlation CoefficientR > 0.999
Net Weight10 kg
Dimensions450 × 320 × 150 mm
Operating SystemWindows XP or later
Integrated Control UnitIndustrial-grade all-in-one PC with 8-inch display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelSP480
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (Triple-Wavenumber Method)
Wavenumber Range3400–2400 cm⁻¹
Wavenumber Accuracy±1 cm⁻¹
Wavenumber Repeatability<±1 cm⁻¹
Baseline Drift≤0.005 AU/60 min
Absorbance Range0.0000–2.0000 AU
Transmittance Accuracy±0.5% T
Linearity Correlation Coefficientr > 0.999
Measurement Accuracy<±5% (5–80 mg/L, 4-cm cell)
Repeatability (RSD)<2% (5–80 mg/L, 4-cm cell)
Detection Limit0.2 mg (absolute, 4-cm cell, standard oil)
Minimum Detectable Concentration0.002 mg/L (4-cm cell, 100× extraction enrichment)
Maximum Measurable Concentration64,000 mg/L (0.5-cm cell, 100× dilution)
Scan Time30 s (full spectrum), <2 s (non-dispersive mode)
Zero Stability±0.5 AU/60 min
Power SupplyAC 220 V ±10 V, 50/60 Hz, 70 W
Operating Environment0–35 °C, 10–90% RH
Dimensions450 × 240 × 100 mm
Weight10 kg
ComplianceGB/T 16488–1996, GB 18483–2001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOILAutoTM-UV-8/10/12/14
Instrument TypeLaboratory-Based
PrincipleUV Spectrophotometry (225 nm)
Measurement Range0–60 mg/L
Detection Limit0.005 mg per measurement (equivalent to 0.001 mg/L at 1 L sample volume)
Accuracy±2% of full scale
Wavelength Resolution1 nm
Optical SystemCzerny-Turner monochromator with holographic grating
Light SourcesDeuterium lamp (190–350 nm), Tungsten lamp (350–1100 nm)
Absorbance Range–0.30 to 3.0 A
Spectral Bandwidth1.8 nm
Wavelength Accuracy±1 nm
Linearity (R²)>0.999
Sample Throughput≤8 min per sample (including extraction, phase separation, adsorption cleanup, and photometric measurement)
Sample Volume100–700 mL (user-selectable)
Extraction SolventHPLC-grade n-hexane (transmittance ≥90% at 225 nm)
Sample Capacity6–14 positions (configurable sequence, infinite loop mode supported)
Separation MethodThree-stage: liquid–liquid extraction → separation tube phase separation → hydrophobic membrane dehydration
Adsorbent CleanupAutomated MgSiO₃ cartridge exchange with reverse-flush regeneration
ComplianceHJ 970–2018 “Determination of Petroleum Hydrocarbons in Water by Ultraviolet Spectrophotometry”
SoftwareWindows-compatible (XP and later), FDA 21 CFR Part 11–ready audit trail, GLP/GMP-compliant data handling, report export to PDF/Word/Excel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOILAutoTM-IR-8 / IR-10 / IR-12 / IR-14
Instrument TypeLaboratory-Based
PrincipleInfrared Spectrophotometry (Triple-Wavenumber Method)
Measurement Range0.01–100 mg/L
Detection Limit0.01 mg/L
Accuracy< ±1%
Spectral Resolution1 cm⁻¹
Sample Throughput6–12 min per sample (including extraction)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOIL-IR-3100
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (Fourier-transform-free, Dispersive Optical Path)
Measurement Range0–600 mg/L
Detection Limit0.1 mg/L (instrument)
Accuracy≤ ±1% (absolute error at 100 mg/L CH, 20 mg/L CH₂/CH₃)
Wavenumber Resolution0.5 nm (equivalent to ~0.3 cm⁻¹ in mid-IR region)
Wavenumber Repeatability±0.01 cm⁻¹
Absorbance Range0.00000–200000 A (logarithmic scale, Lambert–Beer compliant)
Scan SpeedFull-spectrum acquisition in ≤90 s per sample
Wavenumber Range2400–3400 cm⁻¹ (2941–4167 nm)
Cell Pathlength4 cm quartz cuvette
Certified ComplianceHJ 637–2018, HJ 1077–2019, GB 18483–2001
Software FeaturesTriple-wavenumber algorithm (2930, 2960, 3030 cm⁻¹), automatic unit conversion, built-in calibration coefficient matrix (X, Y, Z, F), no standard curve required for quantification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnviron Lab
OriginUSA
ModelOilTech121
Instrument TypePortable
Measurement PrincipleUV-Induced Fluorescence Spectrophotometry
Measurement Range0–1000 ppm and 50 ppb–50 ppm (dual-range)
Detection Limit<5 ppb
Accuracy±5% of reading
Resolution1 ppb
Measurement Frequency60 tests/hour
Measurement Time≤5 seconds per test
DisplayBacklit LCD
Operating Temperature5–40 °C
Auto Power-OffAfter 3 minutes of inactivity
Dimensions195 × 100 × 70 mm
Weight500 g (including batteries)
Power Supply4 × AAA alkaline batteries (>1000 tests per set)
Enclosure RatingIP67
ComplianceEPA Method 1664A-compatible solvent usage (e.g., n-hexane), ASTM D7678 referenced
Sample VesselDisposable quartz-cuvette-style microcell (1.5 mL volume)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSipo Environment
OriginTianjin, China
ModelOIL-IR-2200
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Spectrophotometry (Triple-Wavelength Absorption at 2960 cm⁻¹, 2930 cm⁻¹, and 2870 cm⁻¹)
Measurement Range0–800 mg/L
Detection Limit0.02 mg/L
Accuracy<1% RSD
Spectral Resolution1 cm⁻¹
Full-Spectrum Scan Time60 s per sample
ComplianceHJ 637–2018, HJ 1077–2019