| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Gene Pulser Xcell |
| High Voltage Range | 3000 V |
| Low Voltage Range | 10 V |
| Pulse Duration | 0.05–10 ms (0.05 ms increments) for 10–500 V |
| Number of Pulses | 1–10 (0.1–10 s interval for 10–500 V) |
| Capacitance | 25–3275 µF (25 µF increments) at 10–500 V |
| Resistance | 50–1000 Ω (50 Ω increments) + ∞ |
| Brand | Bio-Rad |
|---|---|
| Model | Helios |
| Origin | USA |
| Type | Handheld Particle-Mediated Gene Delivery System |
| Operating Pressure Range | 100–600 psi |
| Safety Relief Valve Setpoint | 700 ± 35 psi |
| Max. Helium Pressure Adjustment | 800 psi |
| Power Supply | 9 V Alkaline Battery (rechargeable optional) |
| Battery Life | ≥1,000 discharges |
| Max. Discharge Current | 10 mA (gun unit) |
| Input Voltage | 100–120 V or 220–240 V AC, 50/60 Hz |
| Cartridge Spinning Speed | 30 rpm |
| Gold Particle Diameters | 0.6, 1.0, and 1.6 µm |
| PVP Coating Mass | 0.5 g per kit |
| Desiccant | Spherical drying agent (5 units) |
| Cartridge Capacity | 12 firings per chamber |
| Kit Contents | 1,000 pre-loaded cartridges, 50 ft (~26 m) gold-coated tubing, 5 gene storage vials |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | MicroPulser |
| High Voltage Range | 300–3000 V |
| Low Voltage Range | 200–2500 V |
| Pulse Duration | 0.1–5.0 ms (adjustable in 0.1 ms increments) |
| Capacitance Settings | 100, 250, 500, and 1000 µF |
| Internal Resistance | Fixed ~100 Ω (optimized for standard electroporation cuvettes) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | PDS-1000/HE |
| Helium Pressure Range | 450–2200 psi |
| Vacuum Chamber | Adjustable to ≤29 inHg (737 mmHg) |
| Carrier Disk Diameter | 13 mm |
| Stopping Screen Material | Stainless Steel Mesh (100 µm pore) |
| Microprojectile Size Compatibility | 0.6–1.6 µm (Au or W) |
| Pulse Duration | <1 ms (transient helium shockwave) |
| Capacitance | Not applicable (gas-driven, non-electrical acceleration) |
| Resistance | Not applicable (pneumatic system) |
| Brand | BLS |
|---|---|
| Origin | Hungary |
| Model | CF-150C |
| Pulse Voltage Range (Square Wave) | 12–185 V |
| Pulse Duration | 10–200 µs |
| Inter-Pulse Interval | 200 µs |
| Pulse Count | 1–10 |
| HF Oscillator Frequency | 1 MHz ±100 Hz |
| HF Amplitude (Coarse) | 0–30 V<sub>eff</sub> |
| HF Amplitude (Fine) | 0–3 V<sub>eff</sub> |
| Operating Medium | Electrolytic or Non-electrolytic Solutions |
| Dimensions | 200 × 130 × 45 mm |
| Weight | 380 g |
| Power Consumption | 15 VA |
| Protection Class | Class I (Earthed) |
| Brand | BLS |
|---|---|
| Origin | EU-manufactured |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | European Union |
| Model | CF150B |
| Pricing | Available upon Request |
| Brand | BLS |
|---|---|
| Model | FBL/Basic-B&N-01 |
| Power Supply | Dual-mode (battery or AC/DC adapter) |
| Excitation Wavelength Range | 470–660 nm |
| Emission Detection Range | 500–650 nm |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration | 10 ms–10 s |
| Capacitance | 111 µF |
| Resistance | 25 Ω |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Hybrimune |
| Capacity Options | 2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers |
| AC Pre-Fusion Pulse | 0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform |
| AC Post-Fusion Pulse | same frequency/voltage range, ramp-down waveform |
| DC Fusion Pulse | square wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval |
| Cycles | 1–10 sets |
| Operating Temperature | 20–30 °C |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |
| Brand | Drummond |
|---|---|
| Origin | USA |
| Model | Nanoject II Auto-Nanoliter Injector |
| Injection Volume Range | 2.3–69.0 nL |
| Filling Rate | 46 nL/s (fast), 23 nL/s (slow) |
| Injection Rate | 46 nL/s (fast), 23 nL/s (slow) |
| Emptying Rate | 230 nL/s (fast), 92 nL/s (slow) |
| Capillary Material | Borosilicate Glass, Softening Point: 780 °C |
| Included Accessories | 200 borosilicate glass capillaries, maintenance kit, foot switch, universal adapter (3-000-024-A) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Range | 200–2500 V |
| Pulse Duration | 5 ms |
| Capacitance | 10 µF |
| Resistance | 600 Ω |
| Pulse Waveform | Exponential Decay |
| Dimensions (W×D×H) | 19 × 27.5 × 12.5 cm |
| Weight | 3.2 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Interface | USB 2.0 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Type | Adherent-cell-specific electroporation electrode |
| Compatibility | Standard 35 mm Petri dishes with 2 mm gap electrodes |
| Application | In situ transfection of monolayer-cultured mammalian cells |
| Configuration | Dual parallel plate electrode assembly |
| Brand | NanoEnTek |
|---|---|
| Origin | South Korea |
| Model | ExTransfection |
| Type | Benchtop Microchannel Electroporator |
| Application Focus | High-Efficiency Nucleic Acid and RNP Delivery to Primary Cells, Stem Cells, and Immune Cells |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |