Used Liquid Chromatograph
Filter
Showing 511–523 of 523 results
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micromass Quattro Micro |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Product Category | Chromatography & Mass Spectrometry |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Included Components | Waters UPLC system, Edwards vacuum pump, full cable set, validated instrument control and data acquisition software (MassLynx v4.1 or later) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Instrument Type | Triple Quadrupole Liquid Chromatography–Tandem Mass Spectrometer (LC/MS/MS) |
| Configuration | UPLC-Coupled |
| Age | 5–7 years |
| Warranty | 6 months |
| Regulatory Compliance | Fully refurbished to meet ISO/IEC 17025-aligned operational standards |
| Software | MassLynx 4.1 or later, with validated acquisition and processing modules |
| Included Hardware | Binary Solvent Manager, Sample Manager with integrated column oven, Acquity PDA detector, Sample Organizer (optional), dedicated PC workstation |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Nano ACQUITY |
| Instrument Type | Liquid Chromatograph (LC) |
| Flow Rate Range | Nanoflow (50–1000 nL/min) |
| Maximum Pressure | 10,000 psi |
| Column Compatibility | Sub-2 µm particles |
| Detector | Acquity 2996 PDA with Nanoflow Flow Cell |
| Software | MassLynx v4.2 or later |
| Warranty | 6 months |
| Operational Age | 4–5 years |
| Compliance | ASTM D7598, USP <621>, ISO/IEC 17025-aligned operation |
| Data Integrity | 21 CFR Part 11-ready configuration (audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoAcquity UPLC + Q-TOF Premier |
| Product Category | Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Included Sources | ESI and Nano-Electrospray Ionization (nESI) with LockSpray™ Calibration Interface |
| Vacuum System | Edwards XDF 35i Turbo Molecular Pump |
| Data System | Lenovo ThinkCentre M58 PC pre-installed with MassLynx 4.1 software |
| UPS | Toshiba Uninterruptible Power Supply (Model UE3G2L036C61T, S/N 050702XXX) |
| UPLC Serial Numbers | EO5NPA-0XXN, EO5NPB-0XXN, EO5NPS-0XXN |
| Q-TOF Serial Number | HAA09X |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Quattro Micro |
| Instrument Type | Triple Quadrupole Gas Chromatography Tandem Mass Spectrometer (GC-MS/MS) |
| Configuration | Benchtop |
| Ionization Sources | ESI, APCI, ESCi |
| Mass Range | 5–3,000 m/z |
| Scan Speed | Up to 5,000 amu/s |
| Interface Technology | Z-Spray™ ion interface |
| Typical Service Life | 6–8 years |
| Warranty | 6 months post-installation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | SYNAPT G1 HDMS |
| Instrument Type | Hybrid Quadrupole–Time-of-Flight (Q-TOF) Mass Spectrometer with Ion Mobility Separation (IMS) |
| Mass Analyzer Configuration | Dual-Mode TOF (V-mode: >10,000 resolution |
| W-mode | >17,500 resolution) |
| Mass Accuracy | <5 ppm (with lock mass correction, ≤1000 Da) |
| m/z Range | TOF mode — 20–100,000 (V-mode), 20–16,500 (W-mode) |
| Scan Rate | Up to 10 Hz (standard MS/MS), 5 Hz (PDR/E mode) |
| Included Modules | ACQUITY UPLC System (Binary Solvent Manager, Sample Manager, Column Manager, PDA Detector), ESI & NanoSpray Ion Sources, MassLynx 4.2 Software Suite, IMS Hardware, Vacuum System (Agilent G1960-80040 + Varian MS40+ POWERVAR), UPS, Dedicated PC Workstation |
| Refurbishment Standard | Factory-reconditioned per Waters OEM specifications |
| Operational Age | 5–7 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Fully compatible with GLP/GMP data integrity requirements when configured with audit-trail-enabled MassLynx and validated workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-S QTof |
| Instrument Type | Quadrupole Time-of-Flight (Q-TOF) Mass Spectrometer |
| Configuration | Integrated with ACQUITY H-Class UPLC System |
| Age | 4–5 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Software | MassLynx v4.2 or later with UNIFI-ready architecture |
| Detection Mode | Full-scan MS, MSE, MS/MS (via ion mobility-enabled fragmentation), High-resolution accurate-mass (HRAM) acquisition |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-XS QTof |
| Mass Range | 20–16,000 m/z |
| Resolution | >40,000 FWHM (at m/z 556) |
| TOF Mass Range | >100,000 m/z |
| Mass Accuracy | <1 ppm (external calibration) |
| Acquisition Rate | ≥30 spectra/sec |
| Detector | 6 GHz digitizer with 5-decade linear dynamic range |
| Instrument Age | 4 years |
| Warranty | 12 months |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-S Micro |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Dynamic Range | >5 orders of magnitude |
| Detection Mode | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI), switchable |
| Typical Dwell Time | <10 ms per transition |
| Mass Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Scan Speed | Up to 15,000 Da/sec |
| Quantitative Reproducibility | <5% RSD for low-level analytes across multi-day runs |
| Warranty | 6 months limited hardware warranty |
| Operational Age | <12 months |
| Configuration | Integrated with Acquity UPLC I-Class system, Sample Manager, Binary Solvent Manager, Column Heater, MassLynx 4.2 Software Workstation |
| Compliance | Designed to support GLP/GMP workflows with audit trail-capable data acquisition (21 CFR Part 11 readiness via optional software modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-S |
| Instrument Type | Triple Quadrupole LC-MS/MS System |
| Age | 4–5 years |
| Warranty | 6 months |
| Configuration | Acquity UPLC Sample Manager, Binary Solvent Manager, Column Heater, MassLynx 4.1 Workstation PC & Monitor, Pumps & Essential Accessories |
| Condition | Fully Tested & Certified by SpectraLab Scientific |
| Compliance | Meets ASTM D7091, ISO/IEC 17025-relevant operational readiness for regulated labs |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQD IVD |
| Instrument Category | Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) |
| Year of Service | 3–4 years |
| Warranty | 6 months |
| Configuration | Integrated with Waters I-Class UPLC System, LockSpray ESI Source, Acquity SM-FTN Sample Manager (IVD), BSM Binary Solvent Manager (IVD), SO Sample Organizer (IVD), Column Manager (IVD), Roughing Pump, Control PC with MassLynx Software |
| Regulatory Designation | In Vitro Diagnostic (IVD)-Compliant System |
| Condition | Fully Tested & Certified by SpectraLab Scientific |
| Compliance | Meets IVD regulatory requirements for clinical laboratory use under applicable FDA and EU IVDR frameworks |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Xevo TQD |
| Instrument Type | Triple Quadrupole LC-MS/MS System |
| Configuration | Integrated with Waters I-Class UPLC (Acquity SM-FTN Sampler, BSM Binary Solvent Manager, SO Sample Organizer, Column Manager) |
| Age | 3–4 years |
| Warranty | 12 months |
| Compliance | Fully tested and validated per ISO/IEC 17025-aligned refurbishment protocol |
| Software Suite | MassLynx v4.2, TargetLynx, QCMonitor, IntelliStart, Quanpedia, RADAR, TrendPlot |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ZQ-2000 |
| Mass Range | 2–2000 Da (extendable to 4000 Da) |
| Sensitivity | 1 pg reserpine, S/N ≥ 50:1 (ESI+, full scan) |
| Ionization Modes | ESI and APCI with rapid polarity switching |
| Interface | MKII Z-Spray orthogonal interface compatible with volatile buffers |
| Built-in syringe pump | software-controlled, flow range 1–500 µL/min |
| Detection | Positive/negative ion mode switching in < 1 s |
| Software | MassLynx 4.x with QuanLynx and MaxEnt1 modules |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 2–3 years |
| Configuration | Standalone LC/MS system compatible with Waters Alliance 2695/2795 HPLC platforms |