Used Liquid Chromatograph
Filter
Showing 481–510 of 523 results
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | 410 |
| Instrument Type | Differential Refractometer |
| Category | Chromatography Detector |
| Condition | Refurbished & Fully Tested |
| Operational Age | 3–4 Years |
| Warranty | Not Included |
| Regulatory Compliance | Designed for GLP/GMP-adjacent QC environments (non-21 CFR Part 11 compliant out-of-box) |
| Detection Principle | Differential Refractive Index (dRI) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 486 |
| Wavelength Range | 190–380 nm |
| Sensitivity | 0.001 AUFS (Absorbance Units Full Scale) |
| Operational Age | ≥3 years |
| Refurbishment Status | Tested & Verified by SpectraLab Scientific |
| Compliance | Designed to meet legacy ASTM E260 and USP <621> chromatographic detector performance expectations |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 510 |
| Price Range | USD 1,200–6,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Flow Range (Standard) | Up to 9.9 mL/min |
| Flow Accuracy | ±0.5% (typical, per Waters technical specifications) |
| Pressure Rating | Up to 6,000 psi |
| Drive Mechanism | Digital stepper-motor with non-circular gear train |
| Pump Head Options | Standard and extended-flow (up to 22.5 mL/min) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 590 |
| Price Range | USD 1,200 – 6,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Flow Rate Range | 0.001–20.00 mL/min (up to 45 mL/min with extended flow head) |
| Increment Resolution | 0.001 mL/min |
| Method Steps | Up to 40 programmable flow-rate segments |
| Compressibility Compensation | Adjustable digital compensation algorithm |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 650E |
| Instrument Type | Preparative/Analytical HPLC System |
| Configuration | Waters 650E Protein Purification System, Waters 486 Tunable UV Detector, Waters 600 System Controller, Waters 600 Quaternary Gradient Pump |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully tested per ISO/IEC 17025-aligned refurbishment protocol |
| Software Environment | Empower-compatible (legacy method transfer supported) |
| Gradient Accuracy | Fixed low-dead-volume RPS architecture |
| Flow Rate Range | 0.001–25 mL/min (configurable per pump head) |
| UV Detection Range | 190–700 nm, 1 nm resolution |
| System Volume Options | Standard (≥2.5 mL), Low-Dispersion (<1.2 mL), Microbore (<0.3 mL) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 717 Plus |
| Product Category | Chromatography |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY Arc |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty Period | 6 months |
| Instrument Model | ACQUITY Arc |
| Instrument Age | 7 years |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY H-Class |
| Instrument Type | UPLC System |
| Configuration | QSM + SM-FTN + Column Manager + TUV Detector |
| Age | 3–4 Years |
| Warranty | 6 Months |
| Compliance | Fully Tested & Certified per Waters OEM Specifications |
| Software | Empower 3 (or later) Compatible |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY H-Class QDA |
| Detection Principle | Quadrupole Mass Spectrometry coupled with Ultra-Performance Liquid Chromatography (UPLC) |
| Sample Introduction | Flow-Through Needle Autosampler (SM-FTN-R) |
| Solvent Delivery | Quaternary Solvent Manager (QSM-R) |
| Column Management | Column Manager CM-A (4–90 °C, multi-zone) |
| Detector Configuration | PDA (186015032) + QDA MS (186006511) |
| Software Platform | Empower 3 Systems QT |
| Compliance Support | 21 CFR Part 11 audit trail, GLP/GMP-ready workflows |
| Warranty | 12 months limited hardware warranty |
| Instrument Age | <1 year operational use |
| Certification | Factory-tested and validated at SpectraLab Scientific |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | ACQUITY QDa |
| Product Category | Mass Spectrometer |
| Usage Duration | <1 year |
| Warranty | 1 year |
| Included Software | Empower & MassLynx compatibility |
| Regulatory Compliance | Designed for GLP/GMP environments with audit-trail–capable data handling |
| Physical Condition | Factory-new, unopened original packaging, fully tested and verified by SpectraLab Scientific |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY SQD |
| Mass Analyzer Type | Single Quadrupole |
| Ionization Sources | ESI, APCI (ESCi-enabled), optional APPI |
| Mass Range | 20–10000 Da |
| Scan Speed | Up to 10,000 Da/sec |
| Sensitivity | 1 pg on-column (ESI/ACPI) |
| System Integration | Fully coupled with ACQUITY H-Class UPLC platform |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP environments |
| Software | MassLynx v4.2 or later, Empower 3 (with MS extension), optional application-specific toolkits (e.g., TargetLynx, QuanLynx) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | ACQUITY TQD Detector LC/MS/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | Integrated with ACQUITY UPLC System |
| Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Compliance | Designed for GLP/GMP environments, compatible with FDA 21 CFR Part 11–enabled software platforms |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY TQD |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | Integrated with ACQUITY UPLC (SM-FTN, QSM, CH-30A, Vacuum Pump, LAC/E32 Server, Empower & MassLynx Workstation) |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully tested per ISO/IEC 17025-aligned refurbishment protocol |
| Software | MassLynx 4.2+ and Empower 3+ compatible |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem quadrupole mass filtering and collision-induced dissociation (CID) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPLC with Sampler Organizer |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPC2 + QDa |
| Product Category | Mass Spectrometry Detector |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | ACQUITY UPC2 + QDa |
| Sample Injection Range | 0.5–10 µL |
| Primary Mobile Phase | Supercritical CO₂ with Co-solvent |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Ionization (API) coupled to single-quadrupole mass detection |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY UPLC H-Class Bio |
| Instrument Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Bio-QSM Quaternary Solvent Manager, Bio-SM FTN Sample Manager, Column Manager, TUV Tunable UV/Vis Detector |
| Compliance | Designed for biopharmaceutical analysis under GLP/GMP-aligned workflows |
| Software Platform | Empower 3 (or later) compatible |
| Detection Principle | UV/Vis absorbance (190–700 nm, tunable) |
| Flow Path Material | Titanium, PEEK, and bio-inert stainless steel alloys |
| Maximum Pressure | 15,000 psi (103 MPa) |
| Injection Volume Range | 0.1–100 µL (with precision of ±0.3% RSD) |
| Column Temperature Range | 4–100 °C (±0.1 °C stability) |
| Gradient Delay Volume | < 100 µL (system-dependent) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | UPLC H-Class |
| Instrument Category | Liquid Chromatograph |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Quaternary Solvent Manager, Sample Manager-FTN, PDA Detector, FLR Detector, Column Heater |
| Certification Status | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY I-Class |
| Product Category | Chromatography |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | ACQUITY I-Class |
| Instrument Age | 4 years |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPLC Sample Manager |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Temperature Control Range | 4–40 °C (programmable in 1 °C increments) |
| Sample Capacity | Up to 8,064 samples (e.g., 21 × 384-well plates) |
| Ambient Operating Conditions | 20 °C, ≤90% RH (non-condensing) |
| Transport/Storage Range | −30 to 60 °C, ≤90% RH (non-condensing) |
| Acoustic Noise | <65 dB(A) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Acquity UPLC |
| Price Range | USD 38,000–64,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Configuration | Binary Solvent Manager, Sample Manager, PDA eλ Detector, FLR Detector, 30 cm Column Heater/Cooler |
| Condition | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Waters ACQUITY UPLC |
| Price | USD 2,800 (FOB) |
| Product Category | Chromatography |
| Service Life | Refurbished & Fully Qualified |
| Warranty | 6 Months Limited Hardware Warranty |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Ultra-Performance Liquid Chromatograph |
| Model | ACQUITY UPLC |
| Age Range | 5–8 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Software Platform | Empower 3 (or compatible legacy version) |
| Flow Rate Range | Up to 2 mL/min |
| Pressure Rating | Up to 15,000 psi |
| Detection Compatibility | UV/Vis, PDA, or MS interfaces (system-dependent configuration) |
| Column Temperature Control | Ambient to 90 °C |
| Injection Precision | ≤ 0.3% RSD (typical, with standard autosampler) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Ultra-High Performance Liquid Chromatography (UHPLC) Coupled with Single-Quadrupole Mass Spectrometer |
| Model | ACQUITY UPLC + QDa |
| Detection Principle | Electrospray Ionization (ESI) Single-Quadrupole Mass Spectrometry |
| Sample Introduction | LC-coupled ESI source |
| Mass Range | m/z 50–1200 |
| Detection Mode | Full Scan, SIM, AutoMS/MS (optional) |
| Data Acquisition Rate | Up to 10 Hz |
| Software Platform | MassLynx v4.2 or later (with QuanLynx, TargetLynx, and ChromaLynx modules) |
| Compliance | FDA 21 CFR Part 11 ready (audit trail, electronic signature support), GLP/GMP-compatible workflow |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 4–5 years in active service (manufactured ~2013), total system age ≈ 7 years |
| Condition | Refurbished, fully tested and qualified per SpectraLab Scientific QC protocol |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 2690/2695 |
| Configuration | Includes 2996 Photodiode Array Detector (PDA) |
| System Age | 7 years |
| Warranty | 6 months |
| Compliance | Fully tested per ASTM E2681 and USP <621> chromatographic system suitability protocols |
| Software | Empower 2 or 3 (pre-installed, license transferable per Waters policy) |
| Delivery | Bench-ready with validated operational status |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | 2695 |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Includes Waters 2998 Photodiode Array (PDA) Detector |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original OEM functional specifications |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Alliance 2695 (Refurbished) |
| Detector Configuration | 2998 Photodiode Array Detector, 2414 Refractive Index Detector, Fraction Collector III |
| Instrument Age | 4–5 years |
| Warranty | 6 months |
| Category | Liquid Chromatography System |
| Compliance Status | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e2695 |
| Instrument Type | Liquid Chromatograph |
| Detector Type | Photodiode Array (PDA) |
| Software | Empower 3 |
| Operational Age | 7 years |
| Warranty | 6 months |
| Compliance Status | Fully Tested and Certified per SpectraLab Scientific Refurbishment Protocol |
| Included Modules | Quaternary Solvent Manager, Sample Manager (Autosampler), Column Heater/Cooler, Degasser, 2998 PDA Detector |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier XE |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Age | 4 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original factory specifications for mass accuracy, resolution, and sensitivity |
| Software | MassLynx 4.1 or later (license transferable per Waters policy) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Ionization Sources | ESI, LockSpray, optional APCI/APPI/ESCI/NanoLockSpray/MUX |
| Mass Analyzer | Orthogonal Acceleration TOF (oa-TOF) |
| Detector | Dual Microchannel Plate (MCP) Assembly |
| Data Acquisition | 4.0 GHz Time-to-Digital Converter (TDC) with Onboard Histogramming |
| Control & Acquisition Software | MassLynx NT 4.x |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Condition | Factory-refurbished, fully tested and validated |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Micromass LCT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Configuration | Orthogonal Acceleration Reflectron TOF |
| Ionization Source | Z-Spray™ Atmospheric Pressure Ionization (API), Nano-ESI & ESI with LockSpray™ |
| Mass Accuracy | ≤5 ppm RMS (with LockSpray calibration) |
| System Integration | Coupled with Waters 2795 HPLC and Waters 2488 Multi-wavelength UV/Vis Detector |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Condition | Fully tested and refurbished by SpectraLab Scientific |