Used Liquid Chromatograph
Filter
Showing 31–60 of 523 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 1260 Infinity II (G1312B Pump, G1329B ALS, G1322A Degasser, G1316A Column Oven, G4208B Detector) + 1290 Infinity II G1330B Column Compartment |
| Pressure Range | Up to 600 bar |
| Flow Rate Range | Up to 5 mL/min |
| Detection Options | UV-Vis, Fluorescence, ELSD |
| Sample Injection Precision | ≤ 0.25% RSD |
| Column Compatibility | Conventional, sub-2 µm, and superficially porous particles |
| Software Platform | OpenLab CDS (Compatible with ChemStation Legacy Methods) |
| Warranty | 6 months limited warranty |
| Operational Age | 3–4 years |
| Regulatory Compliance | Fully compatible with FDA 21 CFR Part 11 audit trail requirements when configured with validated OpenLab CDS |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260, G1312B |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity II |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Type | Liquid Chromatograph |
| System Configuration | G4302A Binary Pump, G1379B Degasser, G1316A Column Compartment, G4303A Autosampler (Multisampler), G1315D/C Diode Array Detector (DAD), PC with OpenLab CDS Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration Options | 1260 Dual-Gradient High-Pressure Pump / 1260 Infinity II Quaternary Low-Pressure Pump |
| Maximum Pressure | 600 bar |
| Flow Rate Range | 0.05–5 mL/min at 600 bar |
| Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Column Oven Temperature Range | –10 °C to 80 °C (up to 100 °C with optional 1290 Infinity Column Compartment) |
| Temperature Stability | < ±0.15 °C |
| UV Detector Data Acquisition Rate | 80 Hz (DAD, 60 mm flow cell) |
| Baseline Noise | ≤ 0.6 µAU/cm |
| Detection Options | UV/Vis DAD, Fluorescence, ELSD |
| Compliance Features | EMF (Early Maintenance Feedback), RFID-enabled consumables tracking (lamp, flow cell), Data Recovery Card (DRC), GLP/GMP-ready audit trail support via OpenLab CDS |
| Warranty | 12 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | LC-1260 |
| Maximum Pressure | 600 bar |
| Pump Delay Volume | as low as 120 µL |
| Flow Rate Range (Quaternary Pump) | 0.001–10 mL/min |
| DAD Data Acquisition Rate | up to 80 Hz |
| UV Noise Level | < ±0.6 mAU/cm (with 60 mm flow cell) |
| Typical Flow Precision | <0.15% RSD |
| Usage Age | 6–8 years |
| Warranty | 1 year post-installation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 1260 Infinity II |
| Instrument Category | Liquid Chromatography (HPLC) |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Compliance | Fully refurbished to meet Agilent’s certified pre-owned standards |
| Software | OpenLAB CDS (ChemStation or EZChrom compatible) |
| Configuration | Quaternary pump, DAD or VWD detector, thermostatted autosampler, column compartment |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 1290 HTC/HTS |
| Product Category | Chromatography |
| Usage Duration | 2–3 years |
| Warranty | 6 months |
| Sample Capacity | Up to 24 cooled microplates |
| Operating Pressure Rating | 1200 bar |
| Residual Carryover | < 0.001% (DLW-enabled) |
| Software Compatibility | Agilent ChemStation, MassHunter, EZChrom, OpenLab |
| Temperature Control | Refrigerated sample storage (4–10 °C) |
| Vendor Type | Authorized Distributor |
| Import Status | Imported |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration | Binary High-Pressure Pump (G4220A), Autosampler (G4226A) with Thermostatted Tray (G1330B), High-Capacity Column Compartment (G1316C, MCT, −20 °C to 110 °C), DAD (G4212A), VWD (G7114B) |
| Maximum System Pressure | 1300 bar |
| Gradient Delay Volume | < 100 µL |
| DAD Sampling Rate | Up to 240 Hz |
| Baseline Noise (DAD, 60-mm flow cell) | ±0.6 µAU/cm |
| Column Capacity | Up to 8 columns |
| Sample Capacity | Up to 6144 vials (with optional stack expansion) |
| Compliance | ASTM D5503, ISO 17025, USP <621>, FDA 21 CFR Part 11 (when operated with compliant CDS) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1290 Infinity II |
| Instrument Type | UHPLC/HPLC System |
| Maximum Operating Pressure | 1200 bar |
| Flow Rate Range | 0.001–5.0 mL/min |
| Delay Volume | ≤10 µL |
| Column Oven Temperature Range | –10 °C to 100 °C (Peltier-controlled, ±0.05 °C stability) |
| Autosampler Injection Volume | 0.1–40 µL |
| DAD Flow Cell Options | 10 mm Max-Light cartridge cell (standard), 60 mm high-sensitivity Max-Light cartridge cell |
| Data Acquisition Rate | Up to 160 Hz |
| Software Platform | OpenLab CDS (ChemStation-compatible, 21 CFR Part 11 compliant) |
| Warranty | 6 months limited hardware warranty |
| Service History | Fully refurbished, performance-verified per Agilent PQ/QC protocols |
| Operational Age | ~3 years |
| Compliance | ASTM E2689, ISO/IEC 17025-aligned verification, GLP/GMP-ready configuration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1290 Infinity II |
| Configuration | Binary Pump (G4220A), Multisampler (G7167B), Thermostatted Column Compartment (G1316C), Diode Array Detector (G4212B), ChemStation/OpenLab CDS Software |
| Operating Hours | ~12,000–18,000 hrs (equivalent to 3–4 years of routine lab use) |
| Pressure Rating | Up to 1200 bar |
| Detection Wavelength Range | 190–800 nm |
| Flow Rate Range | 0.001–5.0 mL/min |
| Temperature Control Range (Column Oven) | 5–80 °C |
| Warranty | 6 months limited parts & labor |
| Compliance | Fully refurbished and performance-verified per Agilent-recommended protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 200, PSD 120, GTA 120 |
| Product Category | Spectroscopy |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2100 |
| Instrument Age | 4 years |
| Warranty Period | 6 months |
| Price | USD 83,700 |
| Product Category | Electrophoresis-Based Microfluidic Analyzer |
| Regulatory Status | CE-IVD compliant (legacy), FDA-listed for research use only (RUO) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 280FS |
| Product Category | Atomic Absorption Spectroscopy (AAS) |
| Operational Age | 3–4 years |
| Warranty | 1 year |
| Configuration | Includes GTA 120 Graphite Tube Atomizer (G8434A) |
| Compliance Status | Fully refurbished and performance-verified per ASTM E275 and ISO/IEC 17025 guidelines |
| Software Platform | Agilent AA WinLab v4.x with audit trail enabled for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 4100 MP-AES |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Detection Principle | Microwave-induced plasma atomic emission spectroscopy (MP-AES) |
| Compliance | Designed for ASTM D5185, EPA Method 6020B, ISO 11885, and USP <233> elemental analysis workflows |
| Software Platform | Agilent MP Expert v3.x |
| Sample Introduction | Pneumatic nebulization with cyclonic spray chamber and quartz torch |
| Typical Detection Limits | Sub-pptr to low-ppt range for most elements (e.g., Na: 0.003 µg/L, Pb: 0.008 µg/L) |
| Operating Gases | Nitrogen (≥99.998% purity, supplied via liquid N₂ dewar or high-purity gas cylinder) |
| Power Requirement | 208–240 V AC, 50/60 Hz, 20 A |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 490 |
| Instrument Type | Gas Chromatograph |
| Used Duration | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully tested and configured |
| Compliance | Designed for laboratory and field-deployable GC applications |
| Software Platform | Agilent OpenLab CDS |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5890 II S/SL |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 5890 II GC |
| Price Range | USD $1,200 – $6,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | ≥7 years |
| Warranty | 6 months limited hardware warranty |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5890II TCD |
| Price Range | USD $6,800–$13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Detector Configuration | Thermal Conductivity Detector (TCD) + Split/Splitless (S/SL) Inlet |
| Oven Temperature Range | 4°C above ambient to 450°C |
| Temperature Programming | Up to 3 ramps, initial/final holds, 0.1–70°C/min ramp rates, max 650 min run time |
| Injector Zones | Five independently heated zones |
| Column Compatibility | Capillary columns up to 1.2 mm OD |
| TCD Operating Range | Up to 400°C |
| TCD Minimum Detectable | 400 pg/mL carrier gas (equivalent to 1 ppm neon in 1 mL air) |
| TCD Linear Dynamic Range | ±5% over 10⁵ |
| FPD Optional Configurations | Sulfur mode (20 pg S/s, selectivity 10⁵ g S/g C), Phosphorus mode (0.9 pg P/s, selectivity 10⁶ g P/g C) |
| Septum Purge | Built-in at 3 mL/min |
| Back-Pressure Control | Enables independent split flow adjustment without affecting column flow |
| Injection Modes | Split and splitless (purge time adjustable in 0.01-min increments) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5973N (G2576A) |
| Vacuum System | 90 L/s diffusion pump or 250 L/s turbomolecular pump |
| Ion Source | Independently heated electron ionization (EI) source |
| Mass Analyzer | Heated hyperbolic quadrupole mass filter |
| Detector | High-energy dynode (HED) electron multiplier |
| GC/MS Interface | Independently heated transfer line |
| Operating Age | 4 years |
| Warranty | 6 months |
| Compliance | Designed for integration with Agilent 6890 GC systems |
| Software Control | PC-based data system supporting tuning, full-scan acquisition, SIM, spectral library search (NIST), quantitation, and report generation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5975C VL MSD |
| Instrument Type | Quadrupole Mass Spectrometer (Electron Ionization) |
| Detection Principle | Electron Impact Ionization (EI) with Triple-Axis HED-EM Detector |
| Operating Temperature Range | Ion Source up to 350 °C, Quadrupole up to 200 °C |
| Mass Range | 1.6–1050 u |
| Mass Resolution | Unit Mass Resolution (Standard) |
| Dynamic Range | >10⁶ (Peak-to-Peak) |
| Typical Detection Limit (IDL) | <10 fg OFN (Octafluoronaphthalene) in Full Scan Mode |
| Software Platform | Agilent ChemStation (G1701EA) with DRS v2.x and TID Support |
| Compliance | ASTM E260, ISO 17025 (when operated under GLP conditions), USP <1225>, FDA 21 CFR Part 11 (with validated configuration) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5975T |
| Price | USD $350,000 |
| Product Category | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | 5975T |
| Operational Age | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6110A |
| Mass Range | 10–1500 m/z |
| Mass Accuracy | ±0.13 u (scan mode, calibrated range) |
| Mass Stability | ±0.1 u / 12 h |
| Scan Speed | 2500 u/s |
| ESI Sensitivity (SIM) | 10 pg reserpine (m/z 609.3), 100:1 RMS |
| Ionization Modes | ESI & APCI |
| Warranty | 6 months |
| Operational Age | ~3 years |
| Configuration | Integrated with Agilent 1200 Prep HPLC (dual G1361A pumps, G2258A autosampler, G1364B fraction collector, G1315B UV-Vis detector) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Time-of-Flight Mass Spectrometer (oa-TOF) |
| Model | 6210 |
| Configuration | Integrated with Agilent 1200 Series LC (G1312A Binary Pump, G1313A Autosampler, G1316A Column Oven, G1322A Degasser) |
| Ionization Sources Supported | ESI, APCI, APPI, MMI |
| Flow Regime Compatibility | Conventional, Micro, and Nano-LC |
| Operational Age | 4 years |
| Warranty | 6 months |
| Regulatory Readiness | Compliant with GLP/GMP data integrity expectations |
| Software Platform | MassHunter Workstation (vB.07.x or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6224 |
| Instrument Type | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested and Refurbished LC/MS System |
| Compliance | Designed for GLP/GMP- and FDA 21 CFR Part 11–compatible workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6520 |
| Product Type | Mass Spectrometer |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| LC Configuration | Agilent 1200 Series (G1312A Binary Pump, G1313A Autosampler, G1316A Column Compartment, G1322A Degasser) |
| Software Platform | MassHunter Workstation |
| Mass Accuracy (MS) | <2 ppm |
| Mass Accuracy (MS/MS) | <5 ppm |
| Resolution (FWHM) | 20,000 at m/z 556 |
| Dynamic Range (within spectrum) | 10× improvement without sensitivity loss |
| Acquisition Speed | up to 10 MS/MS spectra/sec |
| Mass Range | m/z 25–20,000 |
| Included Hardware | Dedicated PC with pre-installed MassHunter software and calibration kits |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6540A |
| Instrument Type | Quadrupole Time-of-Flight Mass Spectrometer (Q-TOF) |
| Configuration | Integrated with Agilent 1260 HPLC (G1312B binary pump, G1367E high-performance autosampler, G1316A column oven, G1322A vacuum degasser, G1330B autosampler chiller) |
| Software | MassHunter Workstation (Qualitative & Quantitative Analysis) |
| Dynamic Range | Up to 5 orders of magnitude (within-spectrum) |
| Acquisition Rate | Up to 50 spectra/sec |
| Ion Source | Dual AJS (Advanced Jet Stream) ESI/APCI interface |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 922) |
| Warranty | 6 months |
| Service History | Fully refurbished and performance-verified by SpectraLab Scientific |
| Usage Duration | 4 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6850 II |
| Price Range | USD 6,800–13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-6850 Series II |
| Usage Duration | 4–5 Years |
| Warranty | 6 Months |
| Dimensions | 56.8 cm (L) × 28.3 cm (W) × 49.0 cm (H) |
| Column Oven Cooling Capability | Down to –20 °C |
| Detector Options | FID, TCD, FPD, micro-ECD (US only), 5977A MSD |
| Injector Types | SSL, Packed Column, Cold-On-Column, PTV |
| Electronic Pressure Control (EPC) | Yes |
| Autosampler Capacity | Up to 27 × 2 mL vials or 22 × 4 mL vials |
| Network Interface | Built-in LAN |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6850A (G2630A) with FID |
| Product Category | Chromatography |
| Usage Duration | 2–3 years |
| Warranty Period | 6 months |
