Water Quality Analysis
Filter
Showing 31–60 of 3680 results
| Brand | Alalis |
|---|---|
| Model | DO410 |
| Origin | Shanghai, China |
| Instrument Type | Laboratory Benchtop Meter |
| Measurement Principle | Polarographic Electrochemical Probe |
| Dissolved Oxygen Range | 0–20.00 mg/L (ppm) |
| Saturation Range | 0.0–200.0 % |
| Temperature Range | −10 to 110 °C |
| Accuracy (DO) | ±0.30 mg/L |
| Accuracy (Temp) | ±0.4 °C |
| Resolution (DO) | 0.01/0.1 mg/L |
| Resolution (Saturation) | 0.1/1 % |
| Resolution (Temp) | 0.1 °C |
| Repeatability | 0.1 % |
| Detection Limit | 0.10 mg/L |
| Response Time | 30 s (90 % at 25 °C) |
| Residual Current Equivalent | 0.10 mg/L |
| Temperature Compensation | Automatic (0–45 °C) |
| Salinity Compensation | Automatic (0–45 ppt) |
| Atmospheric Pressure Compensation | Automatic (80–105 kPa) |
| Data Storage | 500 sets (manual & auto) |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| IP Rating | IP54 |
| Interface | USB port with included software and cable |
| Power | 9 V AC adapter |
| Electrode | Integrated temperature- and salinity-compensated polarographic probe with replaceable membrane cap and internal electrolyte |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | MP3500 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| DO Range | 0–20.00 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit | 0.01 mg/L |
| DO Temperature Compensation | 0–45 °C |
| DO Salinity Compensation | 0–45 ppt |
| Barometric Pressure Compensation | 80–105 kPa |
| IP Rating | IP57 |
| Data Storage | 1000 sets (GLP-compliant) |
| Display | 68 × 53 mm LCD with white backlight |
| Interface | USB |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | MP6500 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| DO Range | 0–20.00 mg/L |
| DO Accuracy | ±0.30 mg/L |
| DO Repeatability | 0.1% |
| Detection Limit | 0.10 mg/L |
| Temperature Compensation | 0–45 °C (auto), Salinity Compensation: 0–45 ppt (auto), Barometric Pressure Compensation: 80–105 kPa (manual) |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PD320 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Dissolved Oxygen Range | 0.0–20.0 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit (DO) | 0.10 mg/L |
| pH Range | −2.00–19.99 pH |
| mV Range | ±1999 mV |
| Temperature Range | −10–110 °C |
| DO Saturation Range | 0.0–200.0 % |
| pH Resolution | 0.01/0.1 pH |
| mV Resolution | 1 mV |
| DO Saturation Resolution | 0.1/1 % |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH |
| mV Accuracy | ±0.1% FS |
| Temperature Accuracy | ±0.4 °C |
| Response Time (DO) | 30 s (90% at 25 °C) |
| Residual Current | 0.10 mg/L |
| IP Rating | IP57 |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PD5200 |
| Instrument Type | Laboratory |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Dissolved Oxygen Range | 0–20.00 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit (DO) | 0.10 mg/L |
| pH Range | −2.000–19.999 |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10–100 °C |
| Temp Accuracy | ±0.4 °C |
| Response Time (DO) | 30 s (90% at 25 °C) |
| Residual Current | 0.10 mg/L |
| DO Electrode | Membrane-covered polarographic sensor with integrated temperature compensation and salinity/pressure compensation |
| pH Calibration | Up to 5-point auto-calibration with NIST, USA, CH, and custom buffer sets (15 total) |
| Data Storage | 1000 entries (manual/auto), GLP-compliant |
| Connectivity | USB interface |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Br |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Ca |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Measurement Accuracy | ±0.01 pX (for monovalent ions) / ±0.02 pX (for divalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX, 0.01 mol/L, 0.01 mg/L, 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.4 °C |
| Data Storage Capacity | 1000 sets |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Model | PI5100-CL |
| Type | Benchtop Ion Concentration Meter |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-F |
| Instrument Type | Benchtop Ion Analyzer |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-I |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-K |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management, ASTM D1129, ISO 7888, USP <791>, FDA 21 CFR Part 11-ready audit trail support |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Na |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management, supports ASTM D1129, ISO 10523, and USP <791> for ion-selective electrode methodology |
| Brand | CTG |
|---|---|
| Origin | UK |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Parameter | Algal Pigments (Chlorophyll-a, Phycocyanin, Phycoerythrin) and Turbidity |
| Sensor Technology | Submersible Fluorescence Probe (TriLux Series) |
| Data Logger | Hawk Handheld Terminal (IP68-rated, Touchscreen, 2 GB Internal Storage) |
| Power Options | Rechargeable or Disposable Batteries |
| Compliance | Designed for Field-Deployable Environmental Monitoring per ISO 10260, ASTM D3921, and EPA Method 445.0 (Chlorophyll-a by Fluorometric Determination) |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | GGUN-FL24 |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Detection Parameters | Fluorescence (e.g., sodium fluorescein, rhodamine WT, sodium naphthionate), Turbidity, Temperature, Conductivity |
| Fluorescence Detection Limit (sodium fluorescein) | 2 × 10⁻¹¹ g/mL (typ.) |
| Turbidity Range | 0.02–400 NTU |
| Minimum Sampling Interval | 4 s |
| Optical Modules | 4 |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.034 °C |
| ADC Resolution | 24-bit unipolar |
| Operating Current | 8–28 mA |
| Enclosure Material | Stainless Steel |
| Ingress Protection | IP68 |
| Dimensions | Ø48 mm × 270 mm |
| Weight | 2.2 kg |
| Cable Length Options | ≥30 m (cable weight: ~1 kg per 10 m) |
| Power Supply | TRMC-series data loggers (TRMC-GGUN or TRMC-GGUN-COM) |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | GGUN-FL30 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Optical Modules | 4 |
| Turbidity Range | 0.02–400 NTU |
| Fluorescein Sodium Detection Limit | 2 × 10⁻¹¹ g/mL (typical, uranine) |
| Minimum Sampling Interval | 4 s |
| Communication Interface | RS232 |
| Operating Current | 8–28 mA |
| ADC Resolution | 24-bit unipolar |
| Cable Length Options | 15–50 m (1 kg per 10 m) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.034 °C |
| Dimensions | Ø160 mm × 170 mm (cylindrical) |
| Enclosure Rating & Material | IP68, stainless steel |
| Weight | 7.3 kg |
| Power Supply | TRMC-series data logger |
| Optional Local Data Logger | TRMC-GGUN |
| Remote Data Logger Option | TRMC-GGUN-COM |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 µg/L (ppb) as C |
| Accuracy | ±4% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.05 mg/L |
| Repeatability | ≤3% RSD |
| Conductivity Range Limit | <10.0 µS/cm |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Operating Ambient Temperature | 5–40 °C |
| Display | Color Touchscreen |
| Analysis Time | ≤6 minutes per sample |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm (as C) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–90 °C |
| Analysis Time | <6 minutes |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Compliance | Chinese Pharmacopoeia 2010 Edition |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 1 µg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Linearity Error | ±5% |
| Control Interface | Color Touchscreen with Embedded System |
| Connectivity | Bluetooth Wireless Control |
| Compliance | Chinese Pharmacopoeia 2015 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40 |
| Detection Principle | Membrane Conductivity Difference Method |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Operating Environment | 10–40 °C, ≤85% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Detection after UV/Persulfate Oxidation |
| Oxidation Method | High-Temperature Catalytic Combustion (supplemented by UV/persulfate for low-level precision) |
| Measurement Range | 0.01–1000 µg/L (0.01–1.000 mg/L) |
| Accuracy | ±4% of reading within calibrated range |
| Resolution | 0.001 mg/L (1 µg/L) |
| Detection Limit | 0.001 mg/L (1 µg/L) |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤6 minutes per sample |
| Data Storage | Internal memory supporting ≥6 months of timestamped records |
| Compliance | USP <643>, EP 2.2.44, ChP 2020 Edition (General Chapter 0682), FDA CGMP Annex 1 (Water Systems), ISO 8573-1 (for pharmaceutical compressed air-associated water), GLP/GMP-ready audit trail capability |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BC-40A Standard |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | ≤6 minutes |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Differential Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <4 minutes per sample |
| Display | 640×480 color touchscreen |
| Data Storage | 6-month history (≥10,000 records) |
| Interface | RS232 |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | UV/Persulfate Oxidation + NDIR (Non-Dispersive Infrared) Detection |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Response Time | <4 minutes |
| Sample Temperature Range | 1–95 °C |
| Display | 640×480 color TFT touchscreen |
| Data Storage | 6-month history retention |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Interface | RS232 |
| Power Supply | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40A |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature Range | 10–40 °C (max. ±5 °C/day drift) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS/24 h |
| Span Drift | ±5% FS/24 h |
| UV Lamp | Dual-wavelength (185 nm & 254 nm) |
| Pump Tubing | Imported high-stability peristaltic tubing |
| Origin | USA |
|---|---|
| Model | FluoroQuik |
| Excitation Wavelength (Chl a) | 440 nm |
| Emission Wavelength (Chl a) | 670 nm |
| Excitation Wavelength (PC) | 600 nm |
| Emission Wavelength (PC) | 650 nm |
| Sample Volume | 0.5 mL (standard microcentrifuge tube) |
| Live Chl a Range | 0.25–200 ppb |
| Extracted Chl a Range | 0.25–2,500 ppb |
| Live Phycocyanin (PC) Range | 10–1,000 ppb |
| Extracted PC Range | 10–100,000 ppb |
| Detection Output | ppb or Relative Fluorescence Units (RFU) |
| Data Storage | 2 × 400 measurements (per channel) |
| Power Supply | 4 × AA alkaline batteries or 5 V DC / 2 A adapter |
| Dimensions | 5 × 9 × 3.5 cm |
| Weight | 280 g |
| Warm-up Time | < 10 s |
| Interface | LCD touchscreen with bilingual (English/Chinese) firmware |
| Data Transfer | USB port |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Jiangsu, China |
| Model | HQ-5101 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry |
| Compliance | Designed for field-deployable water quality monitoring per ISO 7888 (ammonia nitrogen in water), ASTM D1426–22 (ammonia by direct Nesslerization or UV method), and aligned with EPA Method 350.1 (UV spectrophotometric determination of ammonia nitrogen) |
| Origin | Italy |
|---|---|
| Manufacturer | AMS Group |
| Instrument Type | Laboratory-Based Discrete Chemistry Analyzer |
| Optical Range | 420–880 nm |
| Linear Absorbance Range | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Filter Wheel | 9 + 1 Blind Position |
| Sample Capacity | Up to 126 Positions (5 Racks) |
| Reagent Positions | 16 Total (10 Refrigerated, 6 Ambient) |
| Dispense Volume | 3–450 µL |
| Reaction Temperature Control | 37 °C ±0.1 °C |
| Dimensions (H×W×L) | 42 × 65 × 100 cm |
| Weight | 65 kg |
| Power | 90–250 VAC, 47/63 Hz, 300 W |
| Water Consumption | 2 mL per test |
| Compliance | ASTM, ISO, AOAC, US EPA Methods (incl. EPA 353.2), AFNOR, COFRAC, BATF |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-EC7 |
| Instrument Type | Online |
| Conductivity Ranges | 0–1 mS/cm |
| Outer Diameter | 40 mm |
| Total Length | ~270 mm |
| Weight | ~300 g |
| Housing Material | Titanium |
| Pressure Rating | 6000 m (6000 dbar) |
| Output Signal | 0–2.5 V DC or 0–5 V DC |
| Supply Voltage | 9–18 V DC |
| Connector | SubConn wet-mateable underwater connector |
| Measurement Principle | Seven-electrode AC conductivity with quartz-glass sensing tube |
| Channels | 4 measurement electrodes + 1 excitation + 2 guard/ground electrodes |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S |
| Price | Upon Request |
| Measurement Principle | Amperometric (Clark-type, 3-electrode) |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø24 mm × 235 mm |
| Connector | SUBCONN BH-4-MP (optional alternatives available) |
| Warm-up Time | 5–15 min |
| Electrolyte Consumption | Low |
| Measurement Ranges | Type I: 0.05–10 mg/L H₂S |
| Type II | 0.5–50 mg/L H₂S |
| Type III | 0.01–3 mg/L H₂S |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–30 °C |
| pH Range | 0–8.5 |
| Response Time (t₉₀) | <200 ms |
| Typical Service Life | 5–9 months |
| Pressure Rating | >10 bar |