Water Quality Analysis
Filter
Showing 151–180 of 952 results
| Brand | ASIDA |
|---|---|
| Model | LZ21 |
| Type | Sodium Ion–Specific Dynamic Conductivity-Based Ionic Contamination Tester for Printed Circuit Boards |
| Measurement Principle | Dynamic Extraction + Conductivity Monitoring per IPC-TM-650 2.3.25.1 & J-STD-001 |
| Operating Temperature | 40 °C ± 0.3 °C |
| Extractant Volume Options | 17 L (standard), 30 L (enlarged) |
| PCB Test Area Range | 1200–8712 cm² |
| Conductivity Resolution | 0.0001 µS/cm² |
| Accuracy | ±5% |
| Power | 1700 W |
| Dimensions (enlarged) | 1401 × 600 × 1000 mm |
| Weight (enlarged) | ~150 kg |
| Compliance | IPC-TM-650, J-STD-001, ISO 9001-aligned test environment control |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AVVOR 8000, AVVOR 9000, HM1000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (Portable) & AVVOR 9000 (Online) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Measurable Elements (8000) | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Pd, Sn |
| Measurable Elements (9000) | Cu, Pb, Zn, Cd, Mn, Sb, Sb³⁺, Tl, Fe, Ni, As, Hg, Se, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U |
| Detection Limit | Sub-ppb (ng/L) range for most metals |
| Output Interfaces | Dual 4–20 mA analog outputs (9000), RS-232/RS-485, optional wireless telemetry |
| Software | PC-based control & data logging with audit trail, GLP-compliant reporting |
| Enclosure Rating | IP67 (8000), NEMA 4X / IP66 (9000) |
| Power | Rechargeable Li-ion battery (8000) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (HM-1, HM-2, HM-3) and AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurement Range | Sub-ppb to ppm |
| Electrode Options | Gold, Mercury-film, Bismuth-film, and Bare Carbon Working Electrodes |
| Output Interfaces | Dual 4–20 mA analog outputs, RS-232, RS-485 |
| Compliance | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, and EPA Method 7000B |
| Software | Onboard data logging with timestamped audit trail, GLP-compliant reporting |
| Enclosure Rating | IP65 (AVVOR 8000 series), IP67 (AVVOR 9000 outdoor cabinet) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Instrument Type | Portable (8000) & Online Continuous Analyzer (9000) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Cd, Pb, Zn, Ni, As, Hg, Cr (total & Cr⁶⁺), Fe, Mn, Sb, Tl, Se, Co, Mo, Ag, Au, Pd, Sn, U |
| Measurement Time | ≤30 min per sample (8000) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppt (ng/L) for key elements |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-1 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As(III), Total As, Cd, Cu, Pb, Hg, Mn, Ni, Zn |
| Detection Time | < 300 s per metal |
| Accuracy | ±5% RSD (at 10× LOD) |
| Resolution | 0.1 ppb (for Cd, Pb, Cu in aqueous matrix) |
| IP Rating | IP67 |
| Data Storage | 1000 measurement records |
| Power Options | Rechargeable Li-ion battery, AC adapter, 12 V DC car socket |
| Interface | USB 2.0 |
| Display | Backlit LCD with joystick navigation |
| Electrode System | Triple-electrode immersed probe (WE/RE/AE), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to 3 interchangeable working electrodes in single probe housing |
| Software | Windows-based ASV Analysis Suite with audit trail, calibration history, and report export (PDF/CSV/XLSX) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Detection Principle | Anodic Stripping Voltammetry (ASV) & Cathodic Stripping Voltammetry (CSV) |
| Detection Range | Sub-ppb to low ppb levels (e.g., As(III): 0.05–100 µg/L |
| Cd | 0.02–50 µg/L |
| Pb | 0.03–100 µg/L |
| Hg | 0.01–20 µg/L |
| Cu | 0.05–200 µg/L |
| Zn | 0.1–500 µg/L |
| Ni, Cr, Mn | optional with dedicated electrodes) |
| Measurable Elements | As(III), Total As, Cd, Cr(VI), Cu, Pb, Hg, Mn, Ni, Zn |
| Operating Temperature | –20 °C to +70 °C |
| IP Rating | IP67 |
| Data Storage | 1,000 measurement records with sample ID, timestamp, and operator notes |
| Power Options | Rechargeable Li-ion battery (≥50 assays per charge), AC adapter, 12 V DC car socket |
| Display | 128 × 128 pixel backlit monochrome LCD |
| Interface | Joystick navigation, USB 2.0 for data export and firmware/software updates |
| Electrode System | Triple-electrode immersed probe (working, reference, counter), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to three working electrodes simultaneously installed |
| Compliance | CE-marked |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Hg, Cd, Pb, Cu, Zn, Ni, Cr(VI), As, Mn, Fe, Al, B |
| Detection Time | ≤30 min per sample |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppb (for Hg) |
| IP Rating | IP68 |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12 V DC (cigarette lighter socket) |
| Data Storage | Internal timestamped logging |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Language Support | Multilingual (English, French, Spanish, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Instrument Type | Portable |
| Measurable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Detection Range | ppb to ppm |
| Ingress Protection | IP68 |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Time-stamped internal memory |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Included Accessories | Sample analysis cups, photometric cuvettes, full set of calibration buffers and reagents for 12 metals |
| Language Support | Multilingual interface |
| Electrode System | Triple-electrode immersed probe (working, reference, auxiliary), integrated stirrer and temperature sensor, modular plug-in working electrodes (up to 3 simultaneously) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn (12 metals) |
| Detection Range | ppb to ppm |
| Accuracy | ±7.5% |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Internal timestamped storage with LCD backlight display |
| Interface | Touch keypad, USB for data export |
| Sample Preparation | Minimal—buffer addition and direct water sampling |
| Analysis Time | Rapid (typically < 5 min per metal, multi-parameter in sequence) |
| Electrode System | Triple-electrode immersed probe with integrated stirrer and temperature sensor |
| Expandability | Up to three working electrodes in one probe housing |
| Software | On-device guided workflow with step-by-step visual prompts |
| Language Support | Multilingual UI |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | 11 minutes per sample |
| Accuracy | ±1% RSD |
| Resolution | 1 ppb (for most target metals) |
| Detectable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12V DC car socket |
| Data Logging | Internal timestamped storage |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB and optional Bluetooth for PC data upload |
| Accessories Included | Sample cups, photometric cuvettes, full set of calibration buffers and ASV reagents |
| Language Support | Multilingual UI (English, Spanish, French, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| IP Rating | IP67 |
| Power Options | Rechargeable Battery / AC Adapter / Vehicle Cigarette Lighter Socket |
| Operating Time | Up to 6 h (hot-swappable battery) |
| Connectivity | Wi-Fi, GSM Mobile Internet |
| Electrode Configuration | Triple-electrode system (working, counter, reference) + integrated temperature sensor + built-in micro-stirrer |
| Supported Parameters | As(III), Total As, Bi, Cd, Cr, Co, Cu, Au, Fe, Pb, Mn, Hg, Ni, Sn, Zn |
| Detection Limit | Down to 1 ppb (matrix-dependent) |
| Data Handling | On-device AVVOR software for real-time calibration, peak integration (manual/automatic), regression analysis, correlation coefficient calculation, and direct sample concentration derivation |
| Compliance | Designed for field-deployable compliance with EPA Method 200.8, ISO 11969, and ASTM D3559 (adapted for portable ASV platforms) |
| Brand | AVVOR |
|---|---|
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | ≤1 min per metal |
| Detection Limit | ≤1 ppb (for Pb, Cd, Cu, Zn, As, Hg) |
| Accuracy | ±5% of reading (at 10 ppb level) |
| Resolution | 0.1 ppb |
| Portability | IP67-rated ruggedized field instrument |
| Power Options | Rechargeable Li-ion battery (6 h operation), AC adapter, 12 V DC (cigarette lighter socket) |
| Connectivity | Wi-Fi, GSM/4G LTE, USB, Bluetooth |
| Electrode Configuration | 5 interchangeable sensor modules with integrated temperature probe and magnetic stirrer |
| Software | AVVOR ASV Suite v3.2 (compliant with FDA 21 CFR Part 11 audit trail & electronic signature support) |
| Compliance | Meets ASTM D3559, ISO 8692, USP <232>/<233>, and EPA Method 7000B requirements for trace metal analysis in aqueous matrices |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-3 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Pd, Sn |
| Detection Range | Sub-ppb to low ppm (element-dependent) |
| Portability | Field-deployable with integrated battery and rugged IP67-rated enclosure |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (portable), AVVOR 9000 (online) |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV) |
| Detection Range | Sub-ppb to low ppb (e.g., 0.05–100 µg/L, matrix-dependent) |
| Supported Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Output Interfaces | 4–20 mA (×8), RS-232, RS-485 |
| Data Management | Onboard LCD (AVVOR 8000), Dual-screen option (AVVOR 9000), PC software with audit trail, GLP-compliant reporting |
| Power | Rechargeable Li-ion battery (AVVOR 8000) |
| Enclosure Rating | IP67 (AVVOR 8000) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Price | Upon Request |
| Measurement Range | 0–10 ppm |
| Method | EPA 4500-Cl G (DPD Colorimetric) |
| Resolution | 0.01 ppm (0–6 ppm), 0.1 ppm (6–10 ppm) |
| Accuracy | ±2% (0–6 ppm), ±10% (6–10 ppm) |
| Response Time | 3 seconds |
| Power Supply | 4 × AAA Alkaline Batteries |
| Certification | CE |
| Light Source | LED @ 515 nm |
| Sample Volume | 5 mL |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) and Spectrophotometry |
| Detection Range | Sub-ppb to ppm levels (e.g., As(III): 0.1–100 µg/L, Cd: 0.05–50 µg/L, Pb: 0.05–50 µg/L, Hg: 0.02–25 µg/L, Cu: 0.1–100 µg/L, Zn: 0.5–200 µg/L) |
| Supported Analytes | As(III), Total As, Cd, Cr(VI), Cu, Pb, Mn, Hg, Ni, Zn, Co, Se |
| Compliance | ASTM D3559, ISO 11969, US EPA Method 7000B (ASV), ISO 6603 (spectrophotometric metal chelation) |
| Data Management | Onboard tablet with GLP-compliant audit trail, CFR Part 11–ready export, Wi-Fi/Bluetooth connectivity |
| IP Rating | IP67 (instrument housing and integrated tablet) |
| Power | Rechargeable Li-ion battery (≥12 h continuous operation) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Output Signal | Isolated 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen with multilingual UI |
| Data Storage | Internal memory + optional 8 GB microSD/USB drive |
| Calibration | ≥5-point linear or empirical calibration |
| Brand | AVVOR |
|---|---|
| Model | 9000 |
| Type | Online Ion Analyzer |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Detection Limit | 0.1 ppm |
| Response Time | 30 s |
| Measurement Precision | 0.1 ppm |
| Output Signal | Isolated DC 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen |
| Data Storage | Internal memory + optional 8 GB microSD/USB drive |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Output Signal | Isolated 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen |
| Data Storage | Internal memory (8 GB microSD and USB flash drive optional) |
| Auto-cleaning module | Optional |
| Remote monitoring | Optional 3G/GPRS + web-based SCADA interface |
| SMS alert system | Optional multi-user configurable messaging |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Potentiometric measurement using fluoride-selective ion electrode (F⁻-ISE) with TISAB-based sample conditioning |
| Measurement Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| pH Operating Range | 4–9 (optimized with TISAB buffer) |
| Output Signal | Isolated 4–20 mA, max load 1 kΩ |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen with multilingual UI |
| Data Storage | Internal memory + optional 8 GB microSD/USB storage |
| Auto-cleaning | Configurable timer-based cleaning cycle (cleaning module sold separately) |
| Calibration | ≥5-point linear or empirical calibration curve |
| Compliance | Designed for continuous water quality monitoring per ISO 10304-1, ASTM D1179, and EPA Method 300.0 guidelines |
| Sample Compatibility | Drinking water, surface water, wastewater, industrial effluent, and groundwater |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Pricing | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AVVOR 9000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVVOR 9000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max. Simultaneous Parameters per Module | 5 |
| Max. Modules per System | 2 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, and ASTM D3559-22 compatibility |
| Environmental Rating | IP65 Enclosure with Humidity Control |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 metals each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for ISO 17294-2, ASTM D3559, EPA Method 7000B, and GLP/GMP-aligned data integrity |
| Environmental Rating | IP65 enclosure with humidity-resistant internal architecture |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Sample Inlet | 6–8 mm tubing, pressure-rated for continuous flow |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Sb³⁺, Tl, Fe, Ni, Sn, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> trace metal guidance |
| Environmental Rating | IP65 enclosure with humidity-resistant design |
| Power Supply | 100–240 VAC, 50/60 Hz |