- All
- Favorite
- Popular
- Most rated
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WS198 |
| Temperature Range | Ambient +5 to 40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Oscillation Frequency Range | 20–100 rpm |
| Oscillation Amplitude | 15 / 25 mm |
| Heating Power | 4 kW |
| Chamber Opening Dimensions | 82 × 66 × 50 cm (W×L×D) |
| External Dimensions | 106 × 75 × 75 cm (W×L×H) |
| Working Volume | 50–200 L |
| Compatible Sample Volumes | 25 mL–12 L cryobags |
| Display Resolution | 0.1 °C / 1 rpm |
| Safety Features | Over-temperature, over-current, and low-water-level protection |
| Brand | SOCOREX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Miniature Set |
| Instrument Type | Manual Mechanical Cell Disruptor |
| Sterilization | Autoclavable (121°C, 20 min) |
| Material | Low-Extractable Borosilicate Glass (WHEATON 33) |
| Package Includes | 7 Units (1× Tenbroeck, 1× G.P.I. 0.5 mL, 1× Dounce 1 mL, 1× 0.1 mL, 1× 0.2 mL, 1× Potter-Elvehjem 2 mL, 1× Conical 1 mL) |
| Compliance | USP <661.1>, ISO 8536-1 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-40C |
| Temperature Range | +4 °C to 60 °C |
| Temperature Accuracy (ATC-calibrated) | < ±0.1 °C |
| Temperature Stability | ±1 °C at 37 °C |
| Chamber Volume | 400 L |
| Interior Dimensions (W×D×H) | 630 × 600 × 1100 mm |
| Exterior Dimensions (W×D×H) | 750 × 730 × 1550 mm |
| Net Weight | 160 kg |
| Heating Power | 450 W |
| Refrigeration Power | 400 W |
| Power Supply | AC 220–240 V, 50/60 Hz |
| Shelving | 2 standard / up to 5 stainless steel adjustable shelves |
| Control Interface | Membrane keypad with digital PID temperature regulation |
| Timer Functions | Programmable start/stop/alarm (1 min to 99 h 59 min) |
| Safety Features | Overtemperature cut-off, door-open alarm & auto fan/heater shutdown, audible alert, dual-seal insulated door with anti-fog double-glazed observation window |
| Optional Accessories | Data logging software, external port for sensor calibration or probe insertion, internal power socket, top-mounted LED illumination |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | DIGICEN 21/21R |
| Instrument Type | Benchtop Refrigerated Microplate Centrifuge |
| Max RCF | 26480 × g |
| Max Speed | 16500 rpm |
| Sample Capacity | 4 × 100 mL |
| Acceleration Time | ≥5 s |
| Operating Noise | ≤60 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R449A |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, Directive 2011/65/EU, 2012/19/EU, 98/79/EC |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WT4 |
| Temperature Range | -25 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Dimensions (W×D×H) | 22 cm × 42 cm × 64 cm |
| Heating Power | 1.5 kW |
| Pump Flow Rate | 10 L/min |
| Maximum Pump Pressure | 0.23 bar |
| Bath Capacity | 4–6 L |
| Weight | 24 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | R-8SN |
| Pump Type | Single-Stage Rotary Vane |
| Ultimate Vacuum | 2.5 × 10⁻² mbar |
| Pumping Speed | 120 L/min |
| Motor Power | 250 W |
| Motor Speed | 1400 rpm |
| Noise Level | < 54 dB(A) |
| Oil Capacity | 0.33 L |
| Weight | 11 kg |
| Ingress Protection | IP40 |
| Inlet/Outlet Ports | SAE 3/8″, UNF 7/16″–20 |
| Oil Mist Emission | Low |
| Gas Ballast (Air Bleed) Valve | Integrated |
| Motor Protection | Thermal Overload Cut-off |
| Enclosure Rating | IP54 (Motor) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH200D-1K |
| Temperature Range | 50–300 °C |
| Control Accuracy (PID) | ±1 °C |
| Plate Material | Anodized Aluminum with Ceramic Coating |
| Plate Dimensions | 170 × 170 mm |
| Power Rating | 680 W |
| Temp Uniformity | ±1 °C |
| External Sensor Support | Pt100 |
| Safety Features | Over-Temp Alarm, >60 °C Status LED, Factory Reset, OFF/OFF-Time/WAIT-Time Scheduling (1–9959 min) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WS-350B |
| Display Type | Digital VFD |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Uniformity at 80°C | ±0.3°C |
| Temperature Accuracy at 80°C | ±0.7°C |
| Speed Range (with 96-well plate module) | 150–1500 rpm |
| Speed Range (with 1.5 mL tube module) | 150–1000 rpm |
| Speed Range (with 50 mL tube module) | 150–800 rpm |
| Orbit Diameter | 2 mm |
| Heating Power | 360 W |
| Dimensions (W×D×H) | 276 × 334 × 170 mm |
| Net Weight | 8.3 kg |
| Power Supply | 230 V, 50/60 Hz, 1.7 A |
| Operating Environment | 5–40°C, ≤80% RH |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Ecoloop |
| Control Mode | Manual |
| Rotation Mechanism | Motorized, Bidirectional (Left/Right Adjustable) |
| Sterilization Method | Open-flame thermal sterilization using compatible WIGGENS-Fuego Bunsen burners |
| Detection System | Integrated optical sensor for loop presence/absence detection |
| Auto Shut-off | Yes, configurable at 15 min or 60 min |
| Flame Intensity Settings | 2 levels |
| Post-sterilization Cooling Options | 2 selectable durations |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction Material | Stainless steel |
| Dimensions (W×D×H) | 120 × 150 × 395 mm |
| Weight | 1800 g |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | SES635 |
| Extraction Chamber Volume | 500/1000 mL |
| Receiver Flask Volume | 500/1000 mL |
| Temperature Range | RT +5 °C to +450 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Number of Channels | 3 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-05G |
| Heating Method | Air-Jacketed |
| Temperature Range (with Humidity) | +5°C above ambient to 65°C |
| Capacity | 50 L |
| Temperature Accuracy (at 37°C) | < ±0.3°C |
| Temperature Uniformity (at 37°C) | ±0.1°C |
| Chamber Material | Stainless Steel (AISI 304) |
| Control Interface | High-Resolution Touchscreen PID Controller |
| Power Supply | AC 220–240 V, 50/60 Hz |
| Heating Power | 340 W |
| Dimensions (Interior, W×D×H) | 345 × 368 × 375 mm |
| Dimensions (Exterior, W×D×H) | 440 × 480 × 610 mm |
| Net Weight | 35 kg |
| Safety Features | Independent Over-Temperature Protection, Audible/Visual Alarm, Auto-Heater Cut-Off, Door-Interlocked Fan & Heater Shutdown |
| Optional | RS232 Communication Port, Data Logging Software, Access Ports |
Show next