Empowering Scientific Discovery

Wiggens (Beijing) Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOCOREX
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model357421
Instrument TypeMechanical Tissue Homogenizer (Tenbroeck Design)
SterilizationAutoclavable (121°C, 20 min)
MaterialWheaton 33 Low-Extractable Borosilicate Glass
Grinding Clearance0.09–0.16 mm
Capacity1 mL
Outer Diameter × Length11 mm × 48 mm
Total Length140 mm
Pack Quantity2 units per pack
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWheaton
OriginUSA
ModelCELLine 350 / CELLine 1000
Temperature Control37 °C
Culture Volume (Cell Chamber)5 mL – 15 mL
Chamber ConfigurationDual-compartment (cell chamber + medium reservoir)
Membrane MWCO<10 kDa
Gas ExchangeBottom gas-permeable silicone membrane
SterilizationPre-sterilized, single-use, non-reusable
MaterialMedical-grade polycarbonate and silicone elastomer
CompatibilitySuspension & adherent mammalian cell lines (e.g., CHO, hybridoma, HEK293)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWCI-650CH
Timer Range1 min – 99 h 59 min
Oscillation Frequency30–300 rpm
Amplitude25 mm
Temperature RangeAmbient +5°C to 60°C
Number of Shaking Platforms3
CO₂ Range0–20%
CO₂ SensingDual-beam infrared sensor
Temperature Uniformity±1°C at 37°C
Humidity≥70% RH at 37°C
Heating SystemAir-jacketed, 6-sided heating
FiltrationHEPA sterilizing filter
UV Sterilization4 W UV lamp
Platform Dimensions520 × 520 mm
Internal Dimensions700 × 650 × 1430 mm
Weight323 kg
Power Supply220 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelCelrol Pro / Celrol Elite
Drive TypeBrushless DC Motor
Control SystemSiemens PLC with Touchscreen HMI
Capacity5–55 or 8–88 roller bottles (550 mm length)
Bottle DimensionsØ108–121 mm × 550 mm
Speed Range0.08–2.5 rpm
Speed Resolution0.01 rpm
Rotation DirectionReversible (CW/CCW)
Drive MechanismReinforced Polyurethane Belt
ConstructionFull Stainless Steel (AISI 304)
Power Supply100–240 VAC, 50/60 Hz
Operating Temperature10–40 °C
Humidity Limit≤80% RH at 31 °C
Communication InterfacesRS-232 (Pro), RS-422/RS-485 Modbus RTU, Modbus TCP, TCP/IP (Elite)
Optional AccessoriesBackup Battery, Temperature Monitoring Module, Thermal Printer, Alarm Signal Output
ComplianceDesigned to support GMP-aligned cell culture workflows, compatible with ISO 13485–certified environments and GLP documentation requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelCelrol Elite (GMP Version)
Rotation Speed Range0.08–2.5 rpm (for 110 mm diameter bottles)
Speed Accuracy±0.01 rpm
Bottle Capacity8–88 positions (configurable in 5- or 8-bottle layers)
Bottle DimensionsØ108–121 mm × up to 550 mm length
Drive SystemBrushless DC motor with synchronous polyurethane timing belt
Control InterfaceSiemens PLC-based touchscreen HMI
Communication ProtocolsRS-422 Modbus RTU, RS-485 Modbus RTU, Modbus TCP/IP, TCP/IP
ComplianceFully stainless steel construction compliant with GMP design principles for pharmaceutical bioprocessing
Operating Temperature Range10–40 °C
Humidity ToleranceUp to 80% RH at 31 °C
Power Supply100–240 VAC, 50/60 Hz
CertificationsDesigned to support GLP/GMP audit readiness, compatible with 21 CFR Part 11-compliant data management workflows when integrated with validated SCADA systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelCelrol Elite
Capacity8–88 roller bottle positions
Roller Bottle DimensionsØ108–121 mm × ≤550 mm
Speed Range0.08–2.5 rpm (for Ø110 mm bottles)
Speed Resolution & Accuracy0.01 rpm
Drive TypeBelt-driven, brushless DC motor
Rotation DirectionReversible (CW/CCW)
Control SystemSiemens PLC with touchscreen HMI
Communication InterfacesRS-422 Modbus RTU, RS-485 Modbus RTU, Modbus TCP, TCP/IP
Environmental Operating Range10–40 °C, ≤80% RH at 31 °C
Power Supply100–240 VAC, 50/60 Hz
ConstructionFully stainless steel (AISI 316L-grade contact surfaces), GMP-compliant design
ComplianceDesigned to support ISO 13485, FDA 21 CFR Part 11 (with optional audit trail software), and EU GMP Annex 11 requirements for automated cell culture equipment
Optional AccessoriesUPS-backed real-time clock module, integrated temperature monitoring sensor, thermal printer interface, SCADA integration kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelMIXdrive 1 XS
Timer Range60 min
Temperature Range (Standard)−10 °C to +50 °C
Temperature Range (HT Version)−10 °C to +200 °C (air), up to +95 °C (immersion)
Stirring Positions1
Max Stirring Volume per Position1,000 mL
Max Power Output10 W
Housing MaterialStainless Steel (Standard), High-Temp Alloy (HT Version)
IP RatingIP68
Dimensions (W × D × H)48 × 48 × 18 mm
Weight0.25 kg
Operating Voltage48 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWB-350T
Temperature RangeAmbient +5 to 130°C
Temperature Accuracy±0.1°C
Temperature Uniformity±0.5°C
Dimensions (W×D×H)276 × 334 × 120 mm
Power Supply230 V, 50/60 Hz, 2.8 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelVF12
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelTM-1
Oscillation Frequency0–2500 rpm
Orbital Amplitude4.5 mm
Operating TemperatureAmbient
Platform Quantity1
Drive TypeBrushless DC Motor
Control InterfaceAnalog Knob with Scale Display
Activation ModesTouch-Start and Continuous Operation
Platform CompatibilityStandard Vortex Platform (Interchangeable with Microplate, Tube Rack, and Foam Insert Accessories)
Power Consumption17.3 W
Dimensions (W×D×H)115 × 230 × 60 mm
Weight1.2 kg
ComplianceCE, RoHS, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-600R
Shaker TypeAir-jacketed Temperature-Controlled Orbital/Reciprocating Shaker
Timer Range10 sec – 999 hr 59 min 59 sec
Oscillation Frequency30–300 rpm
Amplitude Options20 mm, 30 mm (standard), 40 mm
Temperature Range15–60 °C
Number of Platforms4
Temperature Accuracy±0.1 °C (at 38 °C)
Temperature Uniformity±1.0 °C (at 38 °C)
Platform Size450 × 450 mm
Internal Chamber Dimensions510 × 510 × 320 mm
Net Weight102 kg
Max Load per Platform15 kg
Drive SystemBrushless DC Motor
Speed Accuracy±1 rpm (at 150 rpm)
Heating Power600 W
Control InterfaceTouch-sensitive PID controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOCOREX
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelPotter-Elvehjem Type
Ultrasonic Power25 W
Operating Frequency50 Hz
Max Temperature100 °C
Sample Volume Range0.1–55 mL
Number of Samples per Run1
Grinding Clearance0.1–0.15 mm
MaterialWheaton 33 Low-Extractable Borosilicate Glass Body with PTFE or Stainless Steel Pestles
SterilizationAutoclavable (121 °C, 20 min)
ComplianceUSP <661>, ISO 8536-1, ASTM E438 Type I, Class A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-50D
Instrument TypeAir-Bath Constant-Temperature Shaker / Orbital Shaker
Timer Range1 min to 99 h 59 min
Oscillation Speed10–300 rpm
Oscillation Amplitude30 mm
Temperature Control RangeAmbient +5°C
Number of Platforms1
DisplayHigh-Contrast LCD
Motor TypeBrushless DC Motor
Control Accuracy±2 rpm (at 100 rpm)
Platform Dimensions (W×D)320 × 260 mm
External Dimensions (W×D×H)355 × 375 × 140 mm
Net Weight20 kg
Operating Environment5–40°C, 50–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-1PLUS
Timing Range1 min – 99 hr 59 min
Oscillation Frequency50–300 rpm
Amplitude40 mm (vertical reciprocating motion)
Temperature RangeAmbient to 60 °C (with optional heating module)
Number of Shaking Platforms6 (3 per side, configurable up to 5 per side)
Max Load per Side3 kg
Clamp CapacityUp to six 1000 mL separatory funnels (configuration-dependent)
Dimensions (L×W×H)445 × 730 × 505 mm
Net Weight90 kg
Power Supply230 VAC, 50 Hz, 0.4 A
Rated Power90 W
Timer Accuracy±1 rpm
ComplianceCE-marked, IEC 61010-1 compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-350W
Timer Range1 min – 99 h 59 min
Oscillation Speed8–100 rpm
Tilt Angle (Rocking Mode)0°–13°
Platform Quantity1
Load Capacity≤5 kg
Motor TypeBrushless DC Motor
DisplayTFT Touchscreen with 1-rpm Resolution
Power Supply100–240 VAC, 50/60 Hz
Dimensions (W×D×H)276 × 343 × 150 mm
Tray Dimensions276 × 276 mm
Net Weight7.3 kg
Housing MaterialsPP, PET, Powder-Coated Steel
Safety FeaturesOverload Protection, Smooth Start, Anti-Slip Silicone Feet & Securing Straps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-100D
Timer Range1–999 min
Oscillation Frequency10–300 rpm
Oscillation Amplitude30 mm (standard), selectable 20/40 mm
Temperature Range5–40 °C
Number of Platforms1
Drive TypeBrushless DC Motor
Control Accuracy±1 rpm
Platform MaterialAnodized Aluminum
Housing MaterialStainless Steel
Max Load Capacity7.5 kg
Platform Dimensions350 × 350 mm
Net Weight24 kg
Power Input/Output45 W / 10 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelV300SS
Vacuum Level≥150 mbar
Air Displacement Rate≤17 L/min
Waste Bottle Capacity1000 mL
Filter Membrane Diameter47/50 mm
Filtration Funnel Capacity300 mL (Borosilicate Glass)
Effective Filtration Area9.6 cm²
Tubing Inner Diameter8 mm
Power Supply220–240 V / 50 Hz
Rated Power60 W
Included ComponentsV300 Vacuum Pump, VF2 Filtration Kit, Electronic Ignition Bunsen Burner, Disc Filters, Silicone Tubing, 0.45 µm Microbiological Membrane Filters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWUS22
Temperature Range20–80 °C
Heating Power550 W
Ultrasonic Frequency37 kHz
Oscillation ModeReciprocating
Oscillation Amplitude20 mm
Oscillation Speed20–200 rpm
Speed Control Accuracy±1 rpm
Timer Range1–199 min
Bath Tray Dimensions (W×D×H)315×205×55 mm
External Dimensions (L×W×H)800×340×390 mm
Drain ValveIntegrated side-mounted
DisplayTFT touchscreen with real-time simultaneous display of set temperature, oscillation speed, and timer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-600
Timer Range10 sec – 999 h 59 min 59 sec
Oscillation Frequency30–300 rpm
Amplitude Options20 mm, 30 mm (standard), 40 mm
Temperature Range+5 to +60 °C
Number of Shaking Platforms4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelHD4200
Instrument TypeUltrasonic Cell Disruptor
Operating Frequency20 kHz
Ultrasonic Power Output50 / 100 / 200 / 400 W (selectable)
Sample Volume Range0.5–3000 mL
Number of Samples per Run1
ComplianceCE-marked, designed for GLP-compliant laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDual-Arm Cell Culture Bottle
Price RangeUSD 280–1,850
Temperature Range0–121 °C
Working Volume Range20–8000 mL
Number of Reactor Vessels1
MaterialLow-Extractable Borosilicate Glass (Type I, ASTM E438 Class A, USP <661> Type I)
Sterilization MethodAutoclavable at 121 °C for 20 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelCelrol Pro
Capacity5–55 roller bottle positions per unit
Roller Speed Range (for 110 mm diameter bottles)0.08–2.5 rpm
Speed Accuracy±0.01 rpm
Bottle Diameter Compatibility108–121 mm
Max. Bottle Length≤550 mm
Drive SystemBelt-driven, brushless DC motor
Rotation DirectionSelectable clockwise or counterclockwise
DisplayHigh-contrast LCD
Power Supply100–240 VAC, 50/60 Hz
Operating Temperature Range10–40 °C
Humidity Limit≤80% RH at 31 °C
Communication InterfaceRS232
Optional AccessoriesBackup battery module, thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOCOREX
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelDura-Grind / Dounce
Instrument CategoryMechanical Cell Disruptor
Ultrasonic Power25 W
Operating Frequency50 Hz
Max Temperature Tolerance100 °C
Sample Volume Range1 mL
ThroughputSingle-sample processing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWIGGENS
OriginGermany
ModelWS-350R
Timer Range1 min to 99 h 59 min
Oscillation Speed5–100 rpm
Tilt Angle7°–13° (adjustable)
Temperature Range5–45 °C
Platform Quantity1
Load Capacity5 kg
Motor TypeBrushless DC Motor
DisplayTFT Touchscreen (1 rpm resolution)
Power Supply100–240 VAC, 50/60 Hz
Dimensions (W×D×H)276 × 320 × 150 mm
Net Weight6.9 kg
Housing MaterialPP, PET, Powder-Coated Steel
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0