| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,950 (FOB) |
| Temperature Range | 121 °C, 132 °C, optional 143 °C |
| Saturation Humidity | 100 % RH |
| Operating Pressure Range | 0–200 kPa (gauge), optional up to 300 kPa |
| Internal Dimensions (Φ × D) | 30×45 cm to 60×65 cm |
| External Dimensions (W × H × D) | 65×100×65 cm to 85×120×90 cm |
| Temperature Uniformity | ≤ ±2 °C |
| Humidity Uniformity | ≤ ±3 % RH |
| Safety Systems | Dual-level overpressure relief valve, auto-fill water level control, real-time pressure/temperature monitoring, interlocked safety door with positive-pressure sealing mechanism, dry-run protection, overtemperature cutoff |
| Power Supply | AC 220 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Lifetime | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer mesh tray or 500-mm-diameter rotating turntable (0–3 rpm) |
| Internal Chamber Material | SUS304 stainless steel |
| External Cabinet | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB China, subject to configuration and customization) |
| Internal Dimensions (L×W×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150 °C (chamber), 40–85 °C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5 °C (temperature), ±2.0% RH (humidity) |
| Uniformity | ±2.0 °C (temp), ±3.0% RH (humidity) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h at standard irradiance setpoints |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior — SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (excl. tax & shipping) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | ≥95% RH |
| UV Spectrum | 290–400 nm (UV-A/B/C selectable) |
| Lamp Power | 40 W |
| Lamp Life | Up to 6,000 h |
| Sample-to-Lamp Distance | 50 mm |
| Lamp Spacing | 35 mm |
| Light Source | Imported Xenon Arc Lamp |
| Cooling | Patented Forced-Air Thermal Management |
| Exposure Modes | Radiant Illumination + Condensation Humidity Cycling |
| Black Panel Temperature Monitoring | Dual-Metal Thermometer |
| Control System | LED-display PID + SSR Microcomputer Controller with Programmable Timer |
| Heating | Nickel-Chromium Alloy Resistive Heater |
| Humidification | Stainless Steel Surface-Evaporation Humidifier |
| Safety Protections | Overtemperature, Leakage Current, Short Circuit, Overcurrent, Low-Water Cut-off |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–12,800 (FOB, model-dependent) |
| Internal Chamber Dimensions (L×W×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Cycle Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer wire mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB) |
| Internal Dimensions (mm) | 500×500×400 / 500×750×600 / 800×800×800 / 1000×1000×1000 |
| External Dimensions (mm) | 1000×1700×900 / 1100×1900×1000 / 1400×1900×1300 / 1650×2100×1500 |
| Temperature Range | 0–100°C (optional up to 150°C) |
| Black Panel Temperature | 40–85°C |
| Humidity Range (Light Cycle) | 20–75% RH |
| Humidity Range (Dark Cycle) | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Temperature Stability | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±2.0% RH |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6.0 kW |
| Lamp Lifetime | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer stainless steel mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Inner Chamber Material | 1.2 mm SUS304 stainless steel |
| Outer Casing | 1.5 mm galvanized steel with powder coating or optional SUS304 |
| Safety Protections | Over-temperature cutoff, high/low pressure monitoring, overload protection, oil pressure safeguard, travel limit switch, earth leakage detection |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-100 |
| Xenon Lamp Power | 1.8 kW |
| Spectral Irradiance Range | 300–800 nm |
| Nominal Irradiance | 550 W/m² ±10% (broadband, 300–800 nm) |
| Light Cycle Duration | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Cooling Method | Water-cooled lamp system |
| Filter Options | Daylight, Window Glass, Extended UV |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-100 |
| Price | USD 5,300 (FOB) |
| Xenon Lamp Power Options | 1.8 kW / 2.5 kW / 6 kW |
| Radiant Flux Density | ≤1200 W/m² |
| Light Exposure Cycle Range | 1 s to 999 h (programmable in seconds, minutes, or hours) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Temperature Range | –10°C to 80°C |
| Black Standard Temperature (BST) Control | 40–80°C |
| Irradiance Control | 0.3–1.0 W/m² @ 340 nm (manual adjustment) |
| Sample Rack | Rotating type (standard), optional fixed or custom large-format |
| Filter Options | Daylight (D65), Window Glass (W), UV-Enhanced |
| Compliance | ISO 4892-2, ASTM G155, SAE J2527, IEC 61215, GB/T 1865 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OK-XD-100.001 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range | 20–75 %RH |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 5,200 (excl. tax & freight) |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| External Dimensions | 1350 × 1850 × 1550 mm (D×W×H) |
| UV-A Spectral Range | 320–380 nm |
| Irradiance Control | Adjustable up to 0.7 W/m² @ 340 nm |
| Humidity Range (Irradiation Mode) | 45–80 %RH |
| Condensation Humidity | ≥95 %RH |
| Black Panel Temperature Range | 30–60 °C (±1 °C tolerance) |
| Irradiation Temperature Range | 50–60 °C (±3 °C tolerance) |
| Condensation Temperature Range | 40–60 °C (±3 °C tolerance) |
| Temperature Resolution | 0.1 °C |
| Condensation Water Depth | ≤30 mm with Auto-Fill Controller |
| Control System | PID Self-Tuning Temperature Regulation |
| UV Radiometer | Fixed-position, high-accuracy broadband sensor |
| Cycle Programming | Dual-mode alternating irradiation/condensation cycles, programmable up to 999 hours per phase |
| Electrical Components | Schneider Electric contactors & circuit breakers |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +85 °C |
| Humidity Range | 10–98% RH |
| Temperature Uniformity | ±3 °C |
| Humidity Uniformity | ±3% RH |
| Temperature Fluctuation | ±3 °C |
| Humidity Fluctuation | ±3% RH |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW |
| Spectral Range | 290–400 nm |
| Irradiance Control | 315 nm band (±5%) |
| Sample Rack Rotation | 1 rpm, 360° |
| Sample-to-Lamp Distance | 300–375 mm |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| Refrigerant | R404A |
| Compressor | Hermetic French Tecumseh Unit |
| Cooling Method | Air-Cooled, Single-Stage |
| Compliance | GB/T 16422.2–1999, GB/T 1865–2007, GB/T 2423.24–1995, ASTM G155, ISO 105-B02/B04, SAE J2527, SAE J2412 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Sample Tray Size | 530 × 730 mm |
| Temperature Range | 40–80 °C (adjustable) |
| Humidity Range | 40–95 %RH (adjustable) |
| Black Panel Temperature | 40–100 °C ±3 °C |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Xenon Lamp | 2 kW single-lamp configuration |
| Lamp Life | 1000 h |
| Irradiance Spectrum | 290–800 nm |
| Sample-to-Lamp Distance | 230–280 mm |
| Rain Cycle Time | 0–9999 min (continuous) |
| Intermittent Rain Interval | 0–240 min |
| Water Spray Cycle | 18 min ON / 102 min OFF or 12 min ON / 48 min OFF |
| Spray Pressure | 0.12–0.15 MPa |
| Nozzle Orifice | Ø0.8 mm |
| Heating Power | 2 kW |
| Humidification Power | 1.2 kW |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Interior Dimensions | 1000 × 1000 × 1000 mm |
| Temperature Range | RT to 80°C (Models B & C) / RT to –80°C (Model A) |
| Humidity Range | 30–90% RH |
| Xenon Lamp Power | 3 kW (Horizontal) / 6 kW (Vertical) |
| Irradiance Control | (550 ± 5) W/m² (290–800 nm) |
| Filter Type | External Quartz Filter |
| Spray System | Stainless Steel Nozzles (Ø0.4 mm), Pressure 78–127 kPa, Programmable On/Off Cycle (1 min–99 h) |
| Dark Cycle | Adjustable (10 min–99 h) |
| Sample Rotation | 360°, 1 rpm (for 75 × 150 mm standard panels) |
| Controller | Touchscreen Programmable LCD Interface |
| Temperature Resolution | ±0.1°C |
| Humidity Resolution | ±1% RH |
| Timer Range | 0–99 h 99 min 99 s |
| Lamp Service Life | >1000 h |
| Compliance | GB/T 8427–1989, GB/T 8430–1998, GB/T 1865–1997, GB/T 16422.2–1999 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | OK-XD-1000.00 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Cycle Programmability | 1–999 h/min/sec (continuous adjustable) |
| Humidity Range (Light Cycle) | 20–75 %RH |
| Compliance | ISO 4892-2, ASTM G155, GB/T 16422.2, ISO 11341, ASTM D6695 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-150 |
| Xenon Lamp Power | 3 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (continuously adjustable) |
| Humidity Range (Light Cycle) | 20–75% R.H. |
| Compliance | ISO 4892-2, ASTM G155, GB/T 16422.2, SAE J2527/J2412 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | OK-XD-153 |
| Price | USD 5,200 (FOB Guangdong) |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤ 1200 W/m² (at sample plane, 300–800 nm) |
| Light/Dark Cycle Programming | 1 s to 999 h, programmable in seconds, minutes, or hours |
| Humidity Control Range | 20–75 %RH (non-condensing), ±3 %RH accuracy |
| Temperature Range (Black Panel) | 40–110 °C |
| Cooling Method | Air-cooled xenon lamp system with forced convection and thermal management |
| Filter Options | Daylight-Q/B, Window Glass-Q/B, Extended UV-Q/B (compliant with ISO 4892-2 spectral requirements) |
| Control System | PLC-based controller with 10.4″ color touchscreen HMI, real-time data logging, USB export, and password-protected user levels |
| Brand | OEM / Third-Party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price Reference | USD 5,200 (excl. tax & freight |
| Effective Irradiation Area | 900 × 210 mm (W × H) |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| UV Irradiance | UVB-313: 0.55 W/m² |
| UVA-340 | 0.68 W/m² |
| Temperature Resolution | 0.1 °C |
| Light Cycle Temperature Range | 50–70 °C (±3 °C tolerance) |
| Condensation Temperature Range | 40–60 °C (±3 °C tolerance) |
| Black Panel Thermometer Range | 30–80 °C (±1 °C tolerance) |
| Water Tray Depth | Auto-controlled |
| External Dimensions | Approx. H1550 × W1350 × D510 mm |
| Lamp Center-to-Center Spacing | 70 mm |
| Minimum Specimen-to-Lamp Distance | ~50 mm |
| Spectral Range (UV-A) | 315–400 nm |
| Humidity Range | 30–80 %RH (light cycle) |
| Humidification Method | Steam generation via SUS304 stainless steel heater and reservoir |
| Humidity Sensor Type | Dry/Wet Bulb |
| Brand | OK |
|---|---|
| Model | OK-XD-200 |
| Chamber Type | Xenon Arc Environmental Aging Chamber |
| Effective Irradiation Area | 900 × 210 mm (W × H) |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| UV Irradiance | UVB-313: 0.55 W/m², UVA-340: 0.68 W/m² |
| Temperature Resolution | 0.1 °C |
| Light Cycle Temperature Range | 50–70 °C (±3 °C tolerance) |
| Condensation Temperature Range | 40–60 °C (±3 °C tolerance) |
| Black Panel Temperature Range | 30–80 °C (±1 °C tolerance) |
| Humidity Range (Light Cycle) | 30–80 %RH |
| (Dark Cycle) | up to 90 %RH |
| Relative Humidity During Exposure | 85–98 %RH |
| Wavelength Range | UV-A: 315–400 nm |
| Lamp Center-to-Center Spacing | 70 mm |
| Specimen-to-Lamp Distance | ~50 mm |
| Chamber Dimensions (H×W×D) | ~1550 × 1350 × 510 mm |
| Construction Material | AISI 304 Stainless Steel (Interior & Exterior) |
| Humidity System | Steam-based, SUS304 stainless steel humidifier and reservoir with auto water-level control |
| Heating Element | Stainless steel electric heating tubes |
| Humidity Sensor | Dry-wet bulb type |
| Sample Rack | Stainless steel and aluminum mesh frame |
| Compliance Standards | ASTM D4329, D4587, D5208, G154, G53 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-225 |
| Interior Dimensions (W×H×D) | 600 × 750 × 500 mm |
| External Dimensions (W×H×D) | 500 × 1380 × 1480 mm |
| Temperature Range | +10 °C to +70 °C |
| Humidity Range | ≥95% RH |
| Specimen Capacity | 75 × 150 mm (standard) |
| Construction | Exterior – Electrostatically coated steel |
| Control System | Programmable touchscreen controller with PID algorithm |
| Cooling Method | Compressor-based refrigeration |
| Illumination Source | Air-cooled xenon arc lamp with borosilicate glass inner/outer filters |
| Irradiance Measurement | Optional fiber-optic radiometer (340 nm or 420 nm bandpass) |
| Safety Protections | Overtemperature cutoff, phase-loss detection, water-level interlock, door safety switch, ground fault circuit interrupter (GFCI), solid-state relay overload protection, fuse-protected control circuitry, acoustic alarm, insulated terminal block |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-225 |
| Xenon Lamp Power Options | 1.8 kW / 2.5 kW / 6 kW (Lamp Lifetime: 1500 h) |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Duration | 1–999 h/min/sec (Programmable) |
| Humidity Range (Light Cycle) | 20–75 %RH |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OK-XD-225 |
| Price | USD 5,300 (FOB Guangdong) |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² (broadband, 290–2500 nm) |
| Light Cycle Duration | 1–999 hours/minutes/seconds (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Temperature Control Range | Ambient +10°C to 80°C (black panel temperature) |
| Cooling Method | Air-cooled lamp system with forced convection |
| Filter Options | Daylight-Q (ISO 4892-2), Window Glass-Q (ISO 4892-2), Extended UV-Q (ASTM G155) |
| Compliance | ISO 4892-2, ASTM G155, ISO 16474-2, SAE J2527, AATCC TM16-3 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-225.000 |
| Xenon Lamp Power | 5 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% R.H. |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB Reference) |
| Chamber Volume | 225 L |
| Internal Dimensions (H×W×D) | 500 × 750 × 600 mm |
| External Dimensions (W×H×D) | 1260 × 1500 × 1100 mm |
| Temperature Range | RT+10°C to 80°C (adjustable) |
| Black Panel Temperature | 63°C or 100°C ±3°C |
| Humidity Range | 45–90% RH (adjustable) |
| Temperature Uniformity | ±0.5°C |
| Irradiance Control | 550 W/m² (290–800 nm) |
| Spectral Filter | <255 nm blocked |
| Lamp Type | 2.5 kW DC air-cooled xenon arc lamp (single tube) |
| Lamp Lifetime | 800–1000 h |
| Sample Tray Size | 450 × 720 mm |
| Rain Cycle Timer | 0–9999 min (continuous) / 0–240 min (interval) |
| Nozzle Orifice | Ø0.8 mm |
| Total Power Consumption | ~9.0 kW |
| Compliance | GB/T 16422.2, ASTM D529, ISO 4892-2 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-225.01 |
| Xenon Lamp Power | 4 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Cycle Timing | 1–999 hours/minutes/seconds (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Cooling Method | Closed-Loop Deionized Water Circulation |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, GB/T 16422.2 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-400 |
| Interior Dimensions (W×H×D) | 470 × 750 × 460 mm |
| Inner Liner Material | SUS304 Stainless Steel |
| Outer Casing | Powder-Coated A3 Steel |
| Temperature Range | RT+10°C to 90°C (±2°C) |
| Black Panel Temperature Range | RT+10°C to 120°C |
| Humidity Range | 45–98% RH (±5% RH) |
| Rainfall Duration | 0–9999 min (continuously adjustable) |
| Light Source | Air-Cooled Xenon Arc Lamp |
| Lamp Power | 5.4 kW |
| Spectral Output | 290–850 nm |
| Sample Holder Capacity | 26 positions, each 200 × 60 mm |
| Compliance | GB/T 16422.2, GB/T 8430, GB/T 1865, GB/T 16259, GB/T 5137.3, GB/T 2423.24, ASTM D4459 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-400 |
| Interior Dimensions (W×H×D) | 470 × 750 × 460 mm |
| Inner Liner Material | SUS304 Stainless Steel |
| Outer Casing | Powder-Coated A3 Steel |
| Temperature Range | RT+10°C to 90°C (±2°C) |
| Black Panel Temperature Range | RT+10°C to 120°C |
| Humidity Range | 45–98% RH (±5% RH) |
| Rainfall Duration | 0–9999 min (continuously adjustable) |
| Light Source | Air-Cooled Xenon Arc Lamp |
| Lamp Power | 5.4 kW |
| Spectral Output | 290–850 nm |
| Sample Holder Capacity | 26 positions, each 200 × 60 mm |
| Compliance | GB/T 16422.2, GB/T 8430, GB/T 1865, GB/T 16259, GB/T 5137.3, GB/T 2423.24, ASTM D4459 |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 50–98% RH |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle | 1–240 min (adjustable interval) |
| Spectral Range | 290–800 nm |
| Xenon Lamp Total Power | 10.5 kW |
| Lamp Life | 1600 h |
| Internal Chamber Dimensions (W×H×D) | 50×76×50 cm |
| External Dimensions | 102×96×137 cm |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 5-wire |
| Operating Ambient | 5–30°C, ≤85% RH |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-500 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Cycle Duration | 1–999 h/min/sec (continuously adjustable) |
| Humidity Range (Light Cycle) | 20–75% R.H. |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-500 |
| Xenon Lamp Power Options | 1.8 kW / 2.5 kW / 6 kW |
| Spectral Irradiance Range | 300–800 nm, calibrated at 550 W/m² ±10% |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Cooling Method | Air-cooled or optional water-cooled lamp system |
| Filter Configurations | Daylight Filter (ISO 4892-2), Window Glass Filter (ISO 16474-2) |
| Black Standard Temperature Control | Ambient to 120°C |
| Sample Rotation | Motor-driven drum rotation for uniform irradiation |
| Compliance | ISO 4892-2, ISO 16474-2, ASTM G155, ASTM D7869, SAE J2527/J2412, GB/T 16422.2, GB/T 1865 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-500.0 |
| Xenon Lamp Power | 5 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Cycle Setting Range | 1–999 h/min/sec (continuously adjustable) |
| Humidity Range (Light Cycle) | 20–75% R.H. |