| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Type | Benchtop Xenon Arc Exposure Chamber |
| Lamp Configuration | Single Xenon Arc Lamp |
| Sample Orientation | Horizontal |
| Optional Accessories | Water Spray System, Refrigerated Cooling Unit |
| Control Interface | Touchscreen with 5-Language Support (English, French, Spanish, Italian, German) |
| Connectivity | Built-in Ethernet |
| Compliance Framework | Designed to support ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, and other photostability/weathering standards |
| Calibration | PATENTED AUTOCAL System for rapid irradiance calibration |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Xenon Lamp Power | 1800 W |
| Irradiance Control | 1.3 W/m² @ 340 nm |
| Light Exposure Duration | Up to 1500 h per cycle |
| Humidity Control | Optional with water spray system |
| Cooling Option | Available with integrated refrigerated cooling unit |
| Compliance | ISO 4892-2, ASTM G155, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Sample Tray Dimensions | 251 mm × 457 mm (9.88" × 18") |
| Lamp Configuration | Single xenon arc lamp |
| Compliance | ISO 4892-1, ISO 4892-2, ISO 11341 |
| Cooling Method | Air-cooled |
| Exhaust | Direct indoor venting enabled |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-1 |
| Xenon Lamp Power | As specified in technical documentation |
| Irradiance Range | ≤1800 W/m² |
| Light Exposure Cycle | 1–9999 hours, continuously adjustable |
| Humidity Control Range | As specified in technical documentation |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q-Sun Xe-1 |
| Xenon Lamp Power | Standard 1.8 kW (air-cooled, single-lamp configuration) |
| Irradiance Range | Up to 1800 W/m² (broadband, 290–2500 nm) |
| Exposure Duration | Adjustable from 1 to 9999 hours (continuous or cyclic) |
| Humidity Control Range | 10–95% RH (operational range, dependent on chamber temperature and filtration configuration) |
| Sample Tray Dimensions | 251 mm × 457 mm (9.88" × 18") |
| Lamp Lifetime | Approx. 1500 hours (typical operational life under standard irradiance setpoints) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-1 |
| Xenon Lamp Power | Not specified (air-cooled single-lamp system) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, or TUV) |
| Light Cycle | Programmable irradiance-on/off cycles with optional water spray and refrigeration |
| Dimensions (W×D×H) | 610 × 584 × 533 mm |
| Sample Tray | 251 × 457 mm (horizontal, flat), accommodates up to seventeen 51 × 102 mm specimens |
| Lamp Life | ~1500 hours (air-cooled xenon arc lamp) |
| Temperature Range | Black Panel: 35–103 °C |
| Air Temperature (with refrigeration option) | 19–103 °C |
| Calibration | NIST-traceable CT202 (temperature) and CR20 (irradiance) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-B |
| Radiant Intensity | ≤1800 W/m² |
| Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Range | Not specified in source |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | 1500 h |
| Black Panel Temperature Control Range | 35–103 °C |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max. Sample Capacity | 15 specimens of 51 mm × 102 mm |
| Filter Options | Daylight-Q/B, Extended UV-Q/B, Window-Q/B/SL/IR |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, ISO 11341, AATCC TM16, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-Sun Xe-1-B |
| Xenon Lamp Power | 1800 W |
| Irradiance Range | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Range | up to 95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-B |
| Xenon Lamp Power | 1800 W |
| Humidity Range | 25–80 %RH |
| Cabinet Type | Benchtop, Single-Lamp, Air-Cooled Xenon Arc Chamber |
| Compliance | ASTM G155, ISO 4892-2, IEC 60068-2-9, SAE J2527, AATCC TM16, GB/T 16422.2 |
| Control System | SOLAR EYE® Irradiance Feedback Control (340 nm, 420 nm, or TUV band selectable) |
| Black Panel Temperature Sensor | CT202-calibrated |
| Interface Languages | English, Spanish, French, German, Chinese |
| Data Logging | Ethernet-enabled real-time data acquisition |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q-SUN Xe-1-BC |
| Xenon Lamp Power | 1800 W |
| Irradiance Control | Solar Eye® Closed-Loop Radiometer System (Selectable Monitoring at 340 nm, 420 nm, or TUV) |
| Humidity Range | 10–95% RH (Controlled & Monitored) |
| Temperature Range | Ambient to 103°C (with optional refrigeration unit: down to 19°C) |
| Sample Capacity | Benchtop Configuration, Single-Lamp Design |
| Compliance Standards | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, ISO 105-B02, ASTM D4459, ASTM D2565 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-Sun Xe-1-BC |
| Xenon Lamp Power | 1800 W |
| Irradiance Range | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Range | up to 95% RH |
| Sample Capacity | 17 specimens (51 × 102 mm each) |
| Lamp Life | ~1500 hours |
| Operating Temperature Range | 19–103 °C (with refrigeration unit) |
| Backside Spray Function | Yes |
| Cooling System | Integrated refrigeration unit |
| Lamp Type | Air-cooled single xenon arc lamp |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-BC |
| Xenon Lamp Power | 1800 W |
| Cooling System | Integrated Refrigerated Chiller |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 15 × 51 mm × 102 mm specimens |
| Lamp Type | Air-Cooled Single Xenon Arc Lamp |
| Lamp Lifetime | ~1500 hours |
| Irradiance Control | SOLAR EYE® Spectral Radiometer (340 nm, 420 nm, or TUV) |
| Temperature Sensing | Black Panel Thermometer (standard), Optional Air Temperature Sensor |
| Filter Options | Daylight-Q/B, Window Glass-Q, Window IR-Q |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-BC |
| Xenon Lamp Power | 1800 W |
| Sample Capacity | 17 specimens |
| Sample Tray Load Capacity | 14 kg (30 lbs) |
| Sample Area | 25 × 46 cm (d × w) |
| Sample Dimensions | 51 × 102 mm |
| Tilt Angle | 10° from horizontal |
| Lamp Type | Full-spectrum xenon arc lamp |
| Irradiance Calibration | AUTOCAL CR20 compliant with ISO standards |
| Black Panel Thermometer | CT202 |
| Water Supply Pressure | 2.1–6.2 bar (30–90 psi) |
| Water Purity | Dissolved solids <1 ppm, suspended silica <0.1 ppm |
| Water Consumption | 0.1 L/min (spray mode) |
| Dimensions (W×D×H) | 78 × 138 × 79 cm |
| Electrical Requirement | 208 V / 230 V |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1-S |
| Lamp Power | 1800 W |
| Sample Capacity | 17 specimens |
| Sample Tray Load Capacity | 14 kg (30 lbs) |
| Sample Area | 25 × 46 cm (d × w) |
| Sample Dimensions | 51 × 102 mm |
| Tilt Angle | 10° from horizontal |
| Lamp Type | Full-spectrum xenon arc lamp |
| Irradiance Calibration | AUTOCAL CR20 compliant with ISO standards |
| Black Panel Temperature Sensor | CT202 |
| Inlet Water Pressure | 2.1–6.2 bar (30–90 psi) |
| Water Purity | <1 ppm dissolved solids, <0.1 ppm suspended silica |
| Water Consumption | 0.1 L/min during spray |
| External Dimensions | 78 × 52 × 65 cm |
| Electrical Supply | 208 V / 230 V |
| Spray Nozzles | 2 (top-mounted) |
| Spray Timing | configurable in light or dark cycles |
| Network Interface | built-in Ethernet for data acquisition |
| User Interface Languages | English, French, Spanish, Italian, German |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Q-SUN Xe-1-S |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 85 °C (operational, black standard thermometer) |
| Humidity Range | 10–95% RH (non-condensing, programmable) |
| Sample Capacity | 17 specimens |
| Sample Tray Tilt Angle | 10° from horizontal |
| Sample Area | 25 × 46 cm (d × w) |
| Max. Sample Size | 51 × 102 mm |
| Sample Tray Load Capacity | 14 kg (30 lbs) |
| Water Inlet Pressure | 2.1–6.2 bar (30–90 psi) |
| Water Purity Requirement | <1 ppm dissolved solids, <0.1 ppm suspended silica |
| Water Consumption | 0.1 L/min (during spray) |
| Dimensions (W×D×H) | 78 × 52 × 65 cm |
| Electrical Supply | 208 V / 230 V, 50/60 Hz |
| Calibration System | AUTOCAL CR20 Radiometer (ISO-compliant) |
| Black Standard Thermometer | CT202 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-SC |
| Xenon Lamp Power | 1800 W |
| Sample Capacity | 17 specimens |
| Sample Tray Dimensions | 25 × 46 cm |
| Sample Size | 51 × 102 mm |
| Sample Tilt Angle | 10° from horizontal |
| Lamp Quantity | 1 full-spectrum xenon arc lamp |
| Black Panel Temperature Range | 15–50 °C (light cycle), 10–40 °C (dark cycle) |
| Water Pressure Requirement | 2.1–6.2 bar (30–90 psi) |
| Water Purity | <1 ppm total dissolved solids, <0.1 ppm suspended silica |
| Water Consumption | 0.1 L/min (during spray) |
| Power Supply | 208 V / 230 V |
| Weight | 124 kg |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1-SC |
| Type | Benchtop Xenon Arc Exposure Chamber |
| Light Source | Single Xenon Arc Lamp |
| Irradiance Control | SOLAR EYE® Closed-Loop Radiometer System (340 nm, 420 nm or TUV selectable) |
| Humidity Control | Standard Relative Humidity (RH) Control |
| Cooling System | Integrated Refrigeration Unit |
| Temperature Range | 19–103 °C (dependent on sensor type, irradiance level, filter configuration, lamp age and ambient conditions) |
| Water Spray | Programmable Spray Cycle |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, and other photodegradation standards |
| Data Interface | Built-in Ethernet port for remote monitoring and data logging |
| Calibration | PATENTED AUTOCAL® Self-Calibration System |
| Diagnostic Capability | Onboard Self-Diagnostic Alerts and Maintenance Reminders |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W |
| Sample Capacity | 31 specimens (46 mm × 122 mm) |
| Lamp Life | ~1500 hours |
| Cooling Type | Air-cooled xenon lamp |
| Filter Options | Daylight, Window Glass, Extended UV |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Humidity Control | Standard RH control (requires deionized water) |
| Water Spray | Optional, top-mounted, operable in both light and dark cycles |
| Temperature Monitoring | Black panel temperature (35–105 °C), chamber air temperature |
| Compliance | Designed to meet ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2, and other international weathering standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W |
| Sample Capacity | 31 specimens (46 mm × 122 mm) |
| Lamp Life | ~1500 hours |
| Cooling Type | Air-cooled |
| Spectral Output | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SunEye® closed-loop feedback system |
| Humidity Range | 10–95% RH (operational, with deionized water) |
| Black Panel Temperature Range | 35–105 °C |
| Chamber Air Temperature Range | Ambient +10 °C to 90 °C |
| Optional Features | Water Spray (front-only or front/back), Multi-language UI (EN/FR/ES/IT/DE), Ethernet connectivity, AUTO-CAL calibration assist |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Temperature Range | Ambient to 85 °C (black panel temperature) |
| Humidity Range | 10–95% RH (controlled) |
| Irradiance Control | 0.35–0.65 W/m² @ 340 nm |
| Sample Rotation | Drum-type sample holder |
| Water Spray | Optional (Xe-2-HS variant) |
| Compliance | ASTM G155, ISO 105-B02/B04/B06, AATCC TM16, ISO 4892-2, JIS D0205, SAE J2527, Ford APG2212, GMW14124, VW PV3929 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2-S |
| Xenon Lamp Power | 1800 W |
| Irradiance | 42 W/m² @ 340 nm |
| Light Exposure Duration | 1500 h (lamp life) |
| Humidity Control | Standard RH control (requires purified water) |
| Water Spray Option | Optional top-mounted spray nozzle (purified water required) |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM 16, AATCC TM 169 |
| Lamp Type | Air-cooled single xenon arc lamp |
| Filter Configuration | Dual-filter assembly (outer borosilicate sleeve + inner 7-piece “Window-IR” or “Window-B/SL” filter set) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Lamp Life | ~1500 hours |
| Control Parameters | Black Panel Temperature, Chamber Air Temperature, Relative Humidity |
| Optional Features | Water Spray Cycle, AUTO-CAL Calibration System |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, ISO 11341, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-Sun Xe-2 |
| Irradiance | 1.3 W/m² @ 340 nm |
| Light Exposure Cycle | 1500 h |
| Humidity Control | Standard Relative Humidity (RH) Regulation |
| Water Spray | Optional |
| Lamp Type | Full-Spectrum Xenon Arc Lamp |
| Sample Mounting | Rotating Drum Configuration |
| Compliance | ASTM G155, ISO 4892-2, ISO 11341, AATCC TM16, SAE J2527, Ford FLTM BI 108-01, GMW 14124 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W |
| Spectral Match | Full-spectrum solar simulation (300–800 nm) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 35–103 °C |
| Relative Humidity Control | Standard, 10–95% RH |
| Water Spray | Optional, programmable during light/dark cycles |
| Sample Capacity | 31 AATCC pre-cut specimens (16 fixtures, 46 × 264 mm each) |
| Lamp Life | Up to 3000 hours |
| Compliance | ISO 4892-2, ASTM G155, AATCC TM16, ISO 105 B02/B04, IEC 60068-2-9, GB/T 8427, SAE J2412, PV 3929, VDA 675242, ASTM D4355 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W |
| Lamp Life | 1500 hours |
| Sample Capacity | 31 specimens (46 mm × 122 mm) |
| Black Panel Temperature Range | 35–105 °C |
| Relative Humidity Control | Standard |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Optional Features | Water Spray, Back-Spray (Xe-2-BS), Multi-language Controller (English, French, Spanish, Italian, German) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02/B04, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Configuration | Rotating Drum |
| Light Source | Xenon Arc Lamp |
| Spectral Range | Full-Spectrum Solar Simulation (290–800 nm) |
| Irradiance Control | Yes, via broadband or narrowband (340 nm or 420 nm) sensors |
| Temperature Control | Chamber Air & Black Panel/Black Standard (BPT/BST) |
| Humidity Control | Yes, RH 10–95% (±3% typical) |
| Water Spray | Optional (Xe-2-HS model) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2, and other major xenon-arc weathering standards |
| Interface Language | English, French, Spanish, Italian, German |
| Data Logging | Built-in Ethernet, real-time data export |
| Calibration | AUTO-CAL™ automated calibration system |
| Continuous Operation | 24/7 unattended operation supported |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN XE-2 X |
| Xenon Lamp Power | 1800 W |
| Cooling Method | Air-Cooled |
| Sample Capacity | 31 specimens (46 mm × 122 mm) |
| Optical System | Dual-filtered borosilicate/quartz lantern assembly |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, Ford PV3930, GMW14124, VW PV 1303, ISO 105-B02, ISO 105-B04 |
| Calibration Traceability | NIST-traceable, ISO/IEC 17025-accredited calibration laboratory |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Xenon Lamp Power | 1800 W |
| Configuration | Rotating Drum Sample Holder |
| Humidity Control | Yes |
| Water Spray Function | Optional (Xe-2-HS) |
| Compliance | ASTM G155, ISO 105-B02/B04/B06, AATCC TM16, ISO 4892-2, JIS D0205, GB/T 8427 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2-H |
| Cooling Method | Air-Cooled |
| Humidity Control | Yes (Electronic RH Sensor) |
| Light Source | 1800 W Xenon Arc Lamp |
| Filter System | Outer Borosilicate or Quartz Glass + 14 Inner Filter Discs |
| Compliance | ASTM, AATCC, ISO, and Other International Weathering Standards |
| Data Connectivity | Ethernet |
| Calibration | AUTO-CAL Patented System |
| User Interface | Multilingual (English, French, Spanish, Italian, German) |
| Sample Mounting | Rotating Drum Rack |
| Measured Parameters | Spectral Irradiance, Radiant Exposure, Relative Humidity, Chamber Temperature, Black Panel/Black Standard Temperature |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2-HS |
| Xenon Lamp Power | 1800 W |
| Cooling Type | Air-Cooled |
| Lamp Life | ~1500 hours |
| Sample Capacity | 31 specimens (46 mm × 122 mm) |
| Standard Humidity Control | Yes |
| Black Panel Temperature Control | Yes |
| Chamber Air Temperature Control | Yes |
| Optional Water Spray | Yes |
| Filter Options | Multiple ISO/AATCC-compliant daylight and extended UV filters |