Xenon Arc Weathering Test Chamber
Filter
Showing 91–120 of 301 results
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-500.00 |
| Xenon Lamp Power | 4 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (continuously adjustable) |
| Humidity Range (Light Cycle) | 20–75 %R.H. |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Power | 9.5 kW |
| Chamber Dimensions (W×D×H) | 950 × 950 × 950 mm |
| Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | 40°C–110°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ≤±0.5°C |
| Lamp Power per Unit | 6.0 kW |
| Lamp Lifetime | ≥500 h |
| Total Exposure Area | ≥6000 cm² |
| Spectral Range | 300–900 nm |
| UV Cutoff | <255 nm (0%) |
| Visible-NIR Transmission | ≥90% (400–800 nm) |
| Irradiance Control Range | 0–1100 W/m² |
| Irradiance Monitoring Options | Broadband (F-ZA radiometer), or narrowband at 340 nm / 365 nm |
| Lamp Cooling | Water-cooled xenon arc lamp |
| Spray Pressure | 78–127 kPa |
| Rainfall Duration | Programmable (1–9999 min), continuous or cyclic |
| Rainfall Intensity | 10±5 mm/h to 100±20 mm/h |
| Cooling System | Hybrid water-to-air heat exchanger with refrigerated compressor and deionized water circulation |
| Humidification | Stainless steel electric humidifier, solid-state control |
| Heating | Nickel-chromium finned heater, zero-crossing SSR control |
| Safety Interlock | Lamp ignition disabled without active coolant flow |
| Compliance Standards | ASTM G155, ISO 4892-2, GB/T 16422.2, GB/T 1865–2009, GB/T 8430–1998, GB/T 16991–1997, GB/T 16259–1996 |
| Brand | OKEO |
|---|---|
| Type | Xenon Arc Weathering Test Chamber |
| Cooling Method | Water-Cooled / Air-Cooled / Benchtop Configurations Available |
| Light Source | 1× Water-Cooled Xenon Lamp or 3× Air-Cooled Xenon Lamps |
| Temperature Range | Ambient to +80 °C (Black Panel) |
| Humidity Control | 10–95% RH (optional) |
| Irradiance Control | 0.35–0.65 W/m² @ 340 nm (adjustable) |
| Rain Simulation | Programmable Spray Cycle (deionized water) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, GB/T 16422.2 |
| Power Supply | 380 VAC, 3-phase, 50/60 Hz |
| Dimensions (Typical Water-Cooled) | W1200 × D1100 × H1900 mm |
| Weight (Typical) | ~450 kg |
| Refrigerant | R404A (CFC-free) |
| Compressor | Tecumseh/Taikang Hermetic Scroll Type |
| Noise Level | <60 dB(A) at 1 m |
| Data Logging | Real-time irradiance, temperature, humidity, spray status |
| Software | OKEO-WeaTest v3.x (multi-language, audit trail, CFR 21 Part 11 compliant export) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5 yr service life |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key Specifications | Temperature Range: 25–40 °C |
|---|---|
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube type |
| Ozone Detection | Non-dispersive UV absorption sensor (≥5-year service life) |
| Compliance | ASTM D1149, ISO 1431-1, GB/T 7762, JIS K 6259 |
| Brand | OK |
|---|---|
| Model | OK-CY Series |
| Type | Environmental Test Chamber |
| Application | Ozone Resistance Testing of Polymers and Rubber |
| Temperature Range | 25–80 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + 7″ Color Touchscreen HMI |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotating (1 rpm), Static/Dynamic Configurable |
| Gas Flow Velocity | 8–16 mm/s |
| Safety Protections | Leakage, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Compliance | GB/T 7762, ISO 1431-1, ASTM D1149, JIS K 6259 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Safety Protections | Leakage, Short-Circuit, Overtemperature, Motor Overheat, Overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel ozone test chamber with fully enclosed silent-discharge ozone generation circuit |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, fluctuation ±0.5 °C |
| Humidity range | 30–65 % RH |
| Sample rack | 360° continuous rotation at 1 rpm (static/dynamic modes optional) |
| Gas flow velocity | 8–16 mm/s |
| Control system | Weilun color touchscreen + Siemens PLC |
| Ozone sensing | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Output | 4–20 mA analog + RS232 digital interface |
| Safety | Leakage, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power supply | AC 380 ±5 V / 50 ±0.5 Hz |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output Interface | 4–20 mA analog output, RS232 serial communication |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 4,100 (FOB) |
| Internal Dimensions (Φ×H) | Φ250×300 mm to Φ650×600 mm |
| Operating Temperature Range | 105–135 °C (143 °C optional) |
| Relative Humidity Range | 70–100 % RH |
| Pressure Range | 0–2.0 kg/cm² (gauge), up to 3.0 kg/cm² on request |
| Safety Features | Water-level sensor, overpressure relief valve, auto-locking door with pressure interlock, P.I.D. saturated steam temperature control |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,950 (FOB) |
| Temperature Range | 105–135 °C (up to 143 °C optional) |
| Humidity Range | 70–100 % RH |
| Pressure Range | 0.0–2.0 kg/cm² (gauge), relative to ambient atmospheric pressure |
| Internal Dimensions (Φ×H, mm) | Φ250×300 / Φ300×450 / Φ450×500 / Φ650×600 |
| External Dimensions (W×H×D, mm) | 500×500×700 / 580×850×650 / 800×750×900 / 950×900×1100 |
| Safety Systems | Low-water cutoff, overpressure relief, interlocked door safety switch, automatic venting |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Standard Accessories | Two stainless-steel adjustable shelves |
| Compliance | Designed per JEDEC JESD22-A108, JESD22-A110, and IEC 60068-2-66 test methodologies |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200–14,800 (FOB, model-dependent) |
| Chamber Volume | 100 L / 225 L / 500 L / 1000 L |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6.0 kW |
| Lamp Life | ≥1,500 h (at nominal irradiance) |
| Spray Cycle | 1–999 min (programmable intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | AIM Box |
| Compliance | ASTM G201, GM 2617M/3619M/7454M/7455M/9538P, Ford DVM 0020, GMW 3417 |
| Light Source | Natural Sunlight with Automotive Glass Filtering |
| Tracking System | Dual-Axis Solar Tracker |
| Temperature Control | Blackboard Thermometer + Active Air-Cooling Fan |
| Sample Capacity | Full-size automotive interior components (dashboards, seats, steering wheels) |
| Spectral Filtering | OEM-grade laminated automotive glass (windshield or side-glass variants per test standard) |
| Operating Environment | Outdoor field exposure site (e.g., Arizona) |
| Calibration & Traceability | ISO/IEC 17025-accredited testing methodology |
| Brand | Q-LAB |
|---|---|
| Origin | China (Hubei) |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PWC |
| Quotation | Available Upon Request |
| Xenon Lamp Power | Configurable per IEC 60068-2-5 & ASTM G155 |
| Temperature Range | –10°C to +80°C (operational, ±0.5°C uniformity) |
| Humidity Range | 10% to 95% RH (±3% RH accuracy) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-LAB B02 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Irradiance Range | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Integrated RH system (range per ISO 105-B02 and AATCC TM16 specifications) |
| Sample Capacity | 31 AATCC specimens (46 × 264 mm each), total exposure area: 1882 cm² |
| Lamp Life | ~1500 hours |
| Calibration Compliance | NIST-traceable, ISO/IEC 17025 accredited (A2LA Cert. #2382-01, #2383-02, #2383-03) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN B02 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Standard |
| Water Spray Option | Available |
| Lamp Type | Air-Cooled 1800 W Xenon Arc Lamp |
| Lamp Life | ~1500 h |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM16 (Options 2 & 3), AATCC TM169, M&S C9/C9A |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-LAB Q-SUN B02 |
| Xenon Lamp Power | 1800 W |
| Irradiance | 42 W/m² (broadband, 300–800 nm) |
| Light Exposure Duration | 1500 h (lamp life at nominal output) |
| Humidity Range | 35–65 % RH |
| Operating Temperature Range | 35–65 °C (chamber air) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Lamp Life | ~1500 hours |
| Filter Configuration | Dual-filter system with outer borosilicate tube and inner 7-piece filter sets (Window-B/SL per AATCC TM16 |
| Compliance | Designed to meet ISO 105-B02, AATCC TM16, and related textile colorfastness standards |
| Cooling Method | Air-cooled lamp assembly |
| Lamp Replacement | Top-access, single connector + two set screws |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02-S |
| Xenon Lamp Power | 1800 W |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM 16 (Option 2 & 3), AATCC TM 169, M&S C9/C9A |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Temperature Control | Blackboard temperature (35–103 °C), chamber air temperature |
| Humidity Control | Relative humidity (RH) with optional water spray |
| Filter System | Dual-filter assembly (outer borosilicate tube + inner 7-element filter set) for Window-IR (ISO/M&S) or Window-B/SL (AATCC) spectral profiles |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model Series | Q-SUN Xe-1, Xe-2, Xe-3 |
| Xenon Lamp Power | 1800 W |
| Irradiance (at 340 nm) | up to 1.30 W/m²/nm |
| Typical Broadband Irradiance | 42 W/m² (with Window-SF5/IR/B04 filters) |
| Lamp Life | up to 3000 h (X-1800+/X-1850+ lamps) |
| Black Panel Temperature Range | 25–120 °C (model-dependent) |
| Relative Humidity Control | 20–95% RH (Xe-2 & Xe-3 only) |
| Water Purity Requirement | >5 MΩ·cm, <0.2 µS/cm, <0.1 ppm TDS (for spray/humidification) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Xenon Lamp Power | 1800 W per lamp |
| Lamp Cooling | Air-cooled |
| Filter Options | Daylight, Window Glass, Extended UV |
| Sample Capacity | Xe-1: 251 mm × 457 mm (flat) |
| Xe-2 | 31 × 46 mm × 122 mm specimens on rotating drum |
| Xe-3 | 451 mm × 718 mm (flat) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Humidity Control | Yes (Xe-2 & Xe-3 standard |
| Water Spray | Yes (deionized water, programmable during light/dark cycles) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1, Q-SUN Xe-3, Q-SUN B02 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Yes (RH range per IEC 60068-2-78 & ASTM G154) |
| Water Spray | Purified water spray, programmable during light/dark cycles |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Filter Options | Daylight, Window Glass, Extended UV (per ISO 4892-2, ASTM G155, SAE J2527) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-Sun Xe-1 |
| Lamp Power | 1800 W |
| Cooling Method | Air-Cooled |
| Lamp Life | ~1500 hours |
| Filter Options | Daylight, Window Glass, Extended UV |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Sample Capacity | Adjustable slide-out tray for 3D specimens |
| Control System | Touchscreen interface with programmable irradiance, temperature & humidity profiles |
| Irradiance Range | 0.35–0.65 W/m² @ 340 nm (adjustable) |
| Temperature Range | 10–90 °C (operational, dependent on filter and irradiance setting) |
| Humidity Range | 10–95% RH (non-condensing, controlled via water reservoir and chamber air circulation) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Sample Tray Dimensions | 251 mm × 457 mm (9.88" × 18") |
| Lamp Configuration | Single air-cooled xenon arc lamp |
| Lamp Lifetime Warranty | 1500 hours |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE Radiometer (340 nm, 420 nm, or TUV) |
| Black Panel Temperature Range | 42–120 °C |
| Filter Options | Daylight, Window Glass, Extended UV |
| Compliance | ASTM G151, ASTM G155, ISO 4892-2, ISO 105-B02, AATCC TM16, SAE J2527, IEC 60068-2-5, GB/T 8427, GB/T 14576, and over 30 additional international standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Xenon Lamp Power | 1800 W |
| Chamber Type | Benchtop |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Software Interface | Q-Lab’s Windows-based SolarEye™ Control Software |
| Language Options | English, French, Spanish, Italian, German |
| Safety Features | Automatic shutdown on fault detection, door interlock, overtemperature protection |
| Cooling Option | Integrated refrigeration unit (optional) |
| Moisture Simulation | Purified water spray system with dual nozzles, programmable in light/dark cycles |
| Temperature Monitoring | Black panel thermometer (BPT) with NIST-traceable calibration support |
| Irradiance Control | SolarEye™ closed-loop feedback system with broadband (340 nm or 420 nm) or TUV sensor options |
| Filter Configurations | Daylight-Q, Window Glass-Q, Extended UV-Q filters |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Cooling Method | Air-cooled |
| Lamp Configuration | Single xenon arc lamp |
| Lamp Life Warranty | 1500 hours |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV) |
| Filter Type | Integrated single-piece borosilicate glass filter |
| Sample Orientation | 10° from horizontal |
| Sample Capacity | 17 specimens (standard flat-panel configuration) |
| Black Panel Temperature Range | Typically 35–110 °C (operational range dependent on irradiance and ambient conditions) |
| Chamber Air Temperature Range | Optional control available |
| Humidity Control | Not standard on Xe-1 |
| Programmable Water Spray | Optional |
| Compliance Support | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 |
| Lamp Power | 1800 W |
| Light Source | Single Air-Cooled Xenon Arc Lamp |
| Lamp Life | ~1500 hours |
| Irradiance Control | SOLAR EYE® Spectral Sensor (340 nm, 420 nm or TUV) |
| Filter Options | Daylight, Window Glass, Extended UV |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Black Panel Temperature Range | 35–103 °C |
| Optional Accessories | Water Spray System, Refrigerated Cooling Unit |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, DIN 75220, BS EN ISO 11341, ANSI Z79.1 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Xenon Lamp Power | 1800 W |
| Black Panel Temperature Range | 35–103 °C (standard), 19–103 °C (with chiller option) |
| Humidity Control | Not available on base model (requires optional water spray system for wetting cycles) |
| Lamp Cooling | Air-cooled |
| Lamp Life | ~1500 hours |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 17 specimens (51 mm × 102 mm each) |
| Filter Type | Single fixed filter (e.g., Daylight-Q, Window-Q, Window-IR) |
| Communication Interface | Ethernet (standard), optional “Virtual Strip” PC software |