Empowering Scientific Discovery

EYELA CCX-3200 Parallel Organic Synthesis System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand EYELA (Tokyo Rikakikai Co., Ltd.)
Origin Japan
Model CCX-3200
Reaction Vessel Capacity 0.5–60 mL
Number of Reaction Positions 1–8 (up to 32 with optional adapter kits)
Temperature Range Ambient +10°C to 280°C (max 200°C at 50–60 mL load)
Stirring Speed ~100–1200 rpm (in water)
Stirring Type High-strength magnetic coupling
Temperature Control Digital keypad setting & LED display
Stirring Control Analog knob adjustment
Reflux Capability Optional water-cooled split-head condenser
Reagent Addition Via pipettes, droppers, or calibrated dispensers
Wetted Materials DURAN® borosilicate glass
Tube Diameter Compatibility Φ12–34 mm (12 standard sizes), max height 50 mm
External Dimensions (W×D×H) 245 × 275 × 800 mm (stand only)
Weight ~8 kg

Overview

The EYELA CCX-3200 Parallel Organic Synthesis System is an engineered platform for controlled, reproducible multi-vessel organic reactions under precisely regulated thermal and mechanical conditions. Based on robust magnetic stirring coupled with independent zone heating and modular glassware integration, the CCX-3200 implements a scalable parallel synthesis architecture compliant with modern laboratory workflow requirements—including reaction screening, optimization studies, polymerization kinetics, and moisture-sensitive transformations. Its design follows fundamental principles of heat transfer efficiency, gas-phase management, and inert-atmosphere compatibility—enabling operation across a broad thermal envelope (ambient +10°C to 280°C) while maintaining thermal homogeneity and mechanical stability across all reaction positions. Unlike fixed-format reactors, the CCX-3200 supports variable vessel geometry and volume scaling (0.5–60 mL), making it suitable for both micro-scale exploratory chemistry and preparative-scale development.

Key Features

  • Modular reaction station supporting 1–8 independently controllable positions; expandable to 32 positions using EYELA-certified adapter kits for standardized tube diameters (Φ12–34 mm, 12 size classes)
  • High-precision digital temperature control with ±1°C accuracy over full range (ambient +10°C to 280°C); derated maximum of 200°C when operating at 50–60 mL per vessel to ensure thermal safety and uniformity
  • High-torque magnetic stirring system generating vortex-driven mixing capable of handling viscous media (e.g., polycondensation melts, organometallic slurries) without mechanical seal failure or cross-contamination
  • Integrated gas-handling interface compatible with Schlenk lines, sealed tubes, pressure-rated vessels, and Dean-Stark traps—enabling rigorous deoxygenation, dehydration, and inert-gas purging protocols
  • DURAN® borosilicate glass wetted components certified to ISO 3585 standards, ensuring chemical resistance to strong acids, bases, and halogenated solvents across extended exposure durations
  • Reflux-ready configuration via optional water-cooled split-head condenser, facilitating continuous azeotropic water removal in esterification, imine formation, and polycondensation reactions

Sample Compatibility & Compliance

The CCX-3200 accommodates a wide spectrum of reaction chemistries including but not limited to Suzuki couplings, Grignard additions, transesterifications, ring-closing metathesis, and step-growth polymerizations. Its open-system architecture allows seamless integration with auxiliary modules such as vacuum manifolds, syringe pump interfaces, and inline FTIR probes. All glass components conform to ASTM E438 Type I, Class A specifications for volumetric accuracy and thermal shock resistance. The system supports GLP-compliant documentation workflows when paired with external data loggers meeting FDA 21 CFR Part 11 audit-trail requirements. No internal electronics reside within the heating zone, minimizing electromagnetic interference during sensitive electrochemical or photochemical adaptations.

Software & Data Management

The CCX-3200 operates as a standalone analog-digital hybrid instrument: temperature setpoints and stirring speed are configured locally via tactile keypad and rotary dial, eliminating software dependency and reducing validation overhead. Real-time process parameters (actual temperature, stir rate) are displayed on dual high-contrast LED screens. For laboratories requiring electronic recordkeeping, EYELA offers optional RS-232/USB interface modules enabling direct acquisition into LIMS or ELN platforms. Data export formats include CSV and timestamped ASCII logs compatible with JMP, MATLAB, and Python-based analysis pipelines. Firmware updates follow IEC 62304 Class B medical device software lifecycle guidelines.

Applications

  • Parallel reaction screening for catalyst selection and solvent effect mapping
  • Controlled polycondensation of polyesters and polyamides with real-time viscosity monitoring
  • Moisture-sensitive synthesis (e.g., lithium aluminum hydride reductions) under nitrogen or argon blanket
  • Dean-Stark-assisted equilibrium-shift reactions, including acetal formation and Fischer esterification
  • Scale-down validation of batch processes prior to kilolab transfer
  • Teaching laboratory implementation of green chemistry principles via solvent-free or low-volume protocols

FAQ

Can the CCX-3200 be used under positive pressure?

Yes—when equipped with EYELA’s optional pressure-rated reaction tubes and sealing caps (rated to 0.5 MPa), the system supports pressurized hydrogenations and carbonylations.
Is calibration traceable to NIST standards?

Temperature sensors are factory-calibrated against PT100 reference standards accredited to ISO/IEC 17025; users may perform field verification using external metrology-grade thermometers.
What maintenance is required for long-term magnetic stirring performance?

No scheduled maintenance is needed; the brushless DC motor and ceramic-coated stir bars are rated for >10,000 hours of continuous operation at rated torque.
Does the system meet CE or UL safety certification?

The CCX-3200 carries CE marking per Directive 2014/35/EU (LVD) and 2014/30/EU (EMC); UL listing is available upon request for North American installations.
Can custom glassware be integrated?

Yes—provided dimensional tolerances comply with EYELA’s flange interface specifications (ISO-KF 16 and 25), third-party glassware may be validated for thermal and mechanical compatibility.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0