Empowering Scientific Discovery

DRETOP DW-100CL Low Temperature Environmental Test Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand DRETOP
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Model DW-100CL
Temperature Range −10 °C to 65 °C
Temperature Uniformity & Fluctuation ±0.5 °C
Cooling Time 30 min
Heating Time 30 min
Temperature Resolution 0.1 °C
Control Accuracy ±0.1 °C

Overview

The DRETOP DW-100CL Low Temperature Environmental Test Chamber is an engineered solution for precise, stable thermal conditioning in laboratory and industrial R&D environments. Designed around a forced-air convection architecture with optimized internal airflow distribution, it operates on the principle of active refrigeration combined with PID-controlled heating—enabling bidirectional temperature regulation across a validated range of −10 °C to +65 °C. Unlike passive cold storage units, this chamber delivers dynamic environmental simulation suitable for stability testing, accelerated aging, material qualification, and microbiological incubation where reproducible thermal profiles are critical. Its robust construction—including a stainless steel interior, insulated double-door system with anti-fog heated viewing window, and modular refrigeration module—ensures long-term operational integrity under continuous duty cycles typical of GLP-compliant laboratories and ISO 17025-accredited test facilities.

Key Features

  • Microprocessor-based P.I.D. temperature controller with 0.1 °C resolution and ±0.1 °C control accuracy; supports programmable ramp-soak profiles and real-time deviation monitoring
  • Forced-air circulation via axial贯流 (cross-flow) fan system with calibrated air duct geometry to maintain ±0.5 °C uniformity and stability throughout the 100 L working volume
  • Energy-efficient hermetic compressor paired with eco-friendly R134a refrigerant (CFC-free), supporting frost-free operation and adaptive cooling power modulation
  • Double-glazed observation window with integrated resistive heating element to prevent condensation and optical distortion during low-temperature operation
  • Stainless steel interior chamber (304 grade) with three adjustable, removable shelves; fully cleanable and compatible with standard lab disinfectants and autoclave validation protocols
  • Modular refrigeration unit incorporating compressor delay start, cycle interval protection, and thermal overload safeguards to extend service life beyond 20,000 operating hours
  • Embedded 25 mm diameter test port with stainless steel plug—designed for feedthrough of sensor cables, power lines, or data acquisition leads without compromising thermal integrity
  • Four-point leveling system with dual-mode mobility: swivel casters (lockable) + independent fixed feet for vibration-dampened placement on uneven lab floors
  • Non-volatile memory with auto-recovery function preserves setpoints and runtime logs after power interruption or controller reset
  • Configurable high/low temperature alarm thresholds with audible and visual alerts; optional external relay output for integration into facility-wide monitoring networks

Sample Compatibility & Compliance

The DW-100CL accommodates a broad spectrum of sample types—including liquid culture media, pharmaceutical intermediates, polymer specimens, electronic components, and biological reagents—without cross-contamination risk due to its seamless stainless steel chamber and absence of organic insulation materials. It meets structural and performance benchmarks aligned with IEC 60068-2-1 (cold testing), IEC 60068-2-2 (dry heat), and ASTM E145–22 (Standard Specification for Gravity-Convection and Forced-Ventilation Ovens). While not certified as Class II biological safety equipment, its design supports compliance with USP environmental controls for stability chambers and aligns with FDA 21 CFR Part 11 requirements when used with optional RS485 interface and audit-trail-enabled software packages. The chamber’s temperature mapping protocol (per IQ/OQ/PQ documentation templates) supports validation in GMP-regulated settings.

Software & Data Management

The DW-100CL operates natively via its onboard LCD interface but integrates seamlessly with third-party data logging platforms through its standard RS485 serial port (Modbus RTU protocol). Optional accessories include a USB-connected miniature thermal printer for hard-copy trend reports and a color touchscreen upgrade offering multi-segment program scheduling, real-time graphing, and CSV export capabilities. All firmware versions support timestamped event logging—including door openings, alarm triggers, and parameter changes—with configurable retention periods. When deployed in networked lab infrastructures, the chamber can be incorporated into centralized environmental monitoring systems (EMS) compliant with Annex 15 and EU GMP guidelines, enabling remote supervision, deviation alerting, and electronic signature workflows.

Applications

  • Accelerated stability testing of APIs and finished dosage forms per ICH Q1A(R3) guidelines
  • Low-temperature characterization of thermoplastic elastomers, adhesives, and composite laminates
  • Cold-chain validation for transport packaging and storage logistics
  • Controlled-environment microbial growth studies requiring sub-zero initiation temperatures
  • Pre-conditioning of sensors, MEMS devices, and optoelectronic assemblies prior to functional testing
  • Calibration verification of reference thermometers and data loggers in accredited metrology labs
  • Long-term storage of sensitive calibration standards, reference materials, and cryo-stable enzymes

FAQ

What is the recommended validation frequency for the DW-100CL in a regulated environment?
Annual IQ/OQ/PQ validation is standard practice; however, temperature mapping should be repeated after any relocation, major maintenance, or firmware update.
Can the DW-100CL operate continuously at −10 °C without defrost cycles?
Yes—the unit employs a no-frost refrigeration architecture with continuous evaporator monitoring, eliminating scheduled defrost interruptions.
Is the 25 mm test port rated for vacuum or pressure differentials?
No—the port is designed solely for ambient-pressure cable feedthrough; external pressure containment requires supplementary sealing solutions.
Does the chamber support external humidity control?
Not natively—the DW-100CL is a dry-air thermal chamber; for combined temp/humidity testing, consider DRETOP’s DH-series environmental chambers.
What is the mean time between failures (MTBF) for the compressor module?
Based on field data from >1,200 installed units, MTBF exceeds 36,000 hours under typical laboratory usage patterns (8 h/day, 5 days/week).