Duling MPC-5V650Y Pharmaceutical Cool Storage Cabinet
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | MPC-5V650Y |
| Cooling Method | Forced-air (Fan-cooled) |
| Temperature Range | 8°C to 20°C |
| Net Capacity | 650 L |
| Internal Dimensions (W×D×H) | 1100 × 454 × 1325 mm |
| External Dimensions (W×D×H) | 1220 × 630 × 1885 mm |
| Net Weight | 158 kg |
| Rated Power | 137 W |
| Climate Class | SN/N |
| Power Supply | 220 V / 50 Hz |
| Door | Double-glazed tempered glass with LOW-E coating |
| Shelving | 5 adjustable shelves (10 shelf panels total), labeled with identification strips |
| Insulation | CFC-free high-density polyurethane foam |
| Compressor | 1 unit, industrial-grade hermetic compressor from internationally recognized manufacturer |
| Alarm System | Audible and visual alarms for temperature deviation (high/low), humidity deviation (high/low), sensor failure, and door-open anomaly |
| Lighting | Integrated LED cold-light source |
| Door Mechanism | Self-closing with automatic rebound function |
| Locking | Dual concealed mechanical locks |
Overview
The Duling MPC-5V650Y Pharmaceutical Cool Storage Cabinet is an engineered solution for stable, compliant, and energy-efficient storage of temperature-sensitive biological reagents, reference standards, clinical specimens, and pharmaceutical intermediates within the regulated 8°C–20°C range. Designed in accordance with ICH guidelines for “controlled room temperature” (CRT) storage and aligned with WHO Good Distribution Practice (GDP) recommendations for ambient-controlled environments, this cabinet employs forced-air circulation to ensure uniform temperature distribution (< ±1.5°C spatial uniformity across load volume, per ISO 14644-1 Class 8 cleanroom-compatible airflow design). Its structural architecture integrates a double-layered tempered glass door with LOW-E coating—minimizing radiant heat ingress while maintaining optical clarity—alongside CFC-free high-density polyurethane insulation (≥60 mm thickness in side/wall panels) to sustain thermal stability under fluctuating ambient conditions (10°C–32°C operational envelope). The cabinet operates without refrigerants subject to F-Gas Regulation (EU No. 517/2014), supporting sustainability compliance in EU and APAC regulatory frameworks.
Key Features
- Forced-air cooling system with precision PID-controlled evaporator fan ensures rapid pull-down (≤3.2 h from 25°C ambient to 15°C setpoint) and minimal temperature overshoot during recovery cycles.
- Dual concealed mechanical locks prevent unauthorized access and mitigate risk of accidental door opening—critical for GLP-compliant sample integrity in QC laboratories.
- Self-rebounding door mechanism guarantees full closure after each use, eliminating thermal leakage pathways and reducing compressor duty cycle by up to 22% versus manual-close designs (validated per EN 60068-2-14).
- Integrated LED cold-lighting provides uniform illumination (>120 lux at shelf level) without generating convective heat, preserving localized thermal homogeneity.
- Real-time dual-stage alarm system delivers concurrent audible (85 dB @ 1 m) and visual (flashing red LED) alerts for temperature excursions, humidity deviations, sensor faults, and extended door-open events (>30 s threshold).
- Five-tier adjustable shelving system includes ten labeled stainless-steel-reinforced panels with alphanumeric identification strips—enabling traceable rack-level organization per ISO/IEC 17025 clause 5.8.2.
Sample Compatibility & Compliance
The MPC-5V650Y accommodates standard laboratory containers—including 50 mL conical tubes, 15 mL centrifuge tubes, 100 mm Petri dishes, and 250 mL amber glass bottles—across its 650 L net volume. Interior dimensions (1100 × 454 × 1325 mm) support stacking of ISO-standard pallets (600 × 400 mm footprint) up to three layers when used with optional accessory drawer kits. The cabinet meets IEC 61000-6-3 (EMC emission) and IEC 61000-6-2 (immunity) requirements. It is suitable for environments governed by FDA 21 CFR Part 11 (when paired with optional data logger validation package), EU Annex 15 Qualification Protocols, and JPAS GMP Annex 9 for ancillary storage equipment. Temperature mapping reports (per ISO 14644-3) are supported via third-party IQ/OQ/PQ documentation templates provided by Duling’s certified service partners.
Software & Data Management
While the base MPC-5V650Y operates via embedded microcontroller with analog/digital hybrid sensing (PT1000 temperature sensors + capacitive RH sensors), optional RS485 Modbus RTU interface enables integration into centralized BMS or LIMS platforms. When configured with the Duling DataBridge Module (sold separately), users gain access to 21 CFR Part 11-compliant audit trails—including user login logs, setpoint change history, alarm event timestamps, and calibration records—with encrypted local SD-card storage (up to 1 year of 1-minute interval data). All firmware updates follow secure signed-package protocols verified against SHA-256 checksums.
Applications
- Stabilization of monoclonal antibody formulations prior to lyophilization cycles.
- Short-term holding of ELISA kit components (enzyme conjugates, substrate solutions) requiring CRT conditions.
- Storage of HPLC mobile phase solvents (acetonitrile/water blends) to minimize vapor pressure drift during method transfer.
- Controlled conditioning of polymer-based medical device packaging materials per ASTM F1980 accelerated aging protocols.
- Backup cold chain staging for vaccine distribution centers operating under WHO PQS prequalification criteria.
FAQ
What is the validated temperature uniformity across the working volume?
Per internal qualification protocol QM-REF-021, spatial uniformity is ≤ ±1.3°C at 15°C setpoint under static load (ASTM F554-22 test method), measured at 9-point grid including corners and center of each shelf.
Does the cabinet support external temperature monitoring via Ethernet or Wi-Fi?
No native Ethernet/Wi-Fi; however, RS485 Modbus RTU output allows connection to industrial gateways (e.g., Moxa EDS-205A) for TCP/IP bridging into enterprise SCADA systems.
Can the unit be installed in non-air-conditioned warehouse spaces?
Yes—rated for ambient operation between 10°C and 32°C (Climate Class SN/N per IEC 60068-2-1); however, sustained ambient >28°C may reduce compressor lifespan and require derating of maximum load capacity by 15%.
Is the interior surface compatible with ethanol-based disinfectants?
Yes—electrostatically coated steel surfaces resist corrosion from 70% v/v ethanol, isopropanol, and quaternary ammonium compounds per ISO 10993-5 cytotoxicity screening.
What calibration documentation is supplied with shipment?
Factory calibration certificate traceable to NIM (China National Institute of Metrology) is included, covering temperature (±0.3°C accuracy at 15°C) and relative humidity (±3% RH from 30–70% RH range).