Empowering Scientific Discovery

Anyty 3R-MSA600SC Portable Digital Microscope with Triple Illumination (White + Infrared + Side Lighting)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Anyty
Origin Beijing, China
Manufacturer Yes
Country of Origin China
Model 3R-MSA600SC
Imaging Sensor 1.3 MP CMOS
Max Optical Magnification 200×
Illumination Modes White LED, Infrared LED, Lateral LED
Field of View Adjustable via focus and working distance
Interface USB 2.0
Compatibility Windows/macOS/Linux (UVC-compliant, no driver required)
Focus Mechanism Manual coaxial fine-focus knob
Working Distance 35–85 mm (dependent on magnification and lens configuration)

Overview

The Anyty 3R-MSA600SC is a field-deployable digital microscope engineered for rapid, non-contact surface inspection across industrial QA, forensic documentation, electronics failure analysis, and educational laboratories. Unlike traditional compound microscopes, it operates on a coaxial optical path with integrated triple-spectrum illumination—white light for true-color morphology, infrared (850 nm) for subsurface contrast enhancement in semi-transparent materials (e.g., polymer coatings, solder mask layers), and lateral (oblique) lighting to accentuate topographic relief, edge definition, and micro-scratches. Its 1.3 MP UVC-compliant CMOS sensor delivers real-time 720p video at 30 fps and still captures at full resolution without proprietary drivers—ensuring seamless integration into existing imaging workflows under Windows, macOS, and Linux environments. The device employs fixed-focal-length optics calibrated for consistent magnification fidelity across its 200× maximum total magnification range (achieved via combined optical zoom and digital interpolation optimized for edge-preserving sharpening). Designed for benchtop, handheld, or stand-mounted use, the 3R-MSA600SC features a ruggedized aluminum housing, thermal-stable lens barrel, and ESD-safe construction compliant with IEC 61340-5-1 for electronics handling.

Key Features

  • Triple-illumination system: Independently switchable white (5500 K CCT), infrared (850 nm peak), and lateral LED arrays—enabling multimodal contrast optimization without external accessories.
  • Coaxial manual focus with dual-scale vernier dial: Provides repeatable focusing accuracy within ±2 µm over a 35–85 mm working distance range.
  • USB 2.0 UVC-class interface: Plug-and-play operation; compatible with industry-standard imaging software (e.g., ImageJ, Olympus Stream, HALCON SDK) and custom LabVIEW or Python-based acquisition scripts.
  • Optimized optical train: Multi-element achromatic objective lens with anti-reflective broadband coating (400–1000 nm), minimizing chromatic aberration and flare during high-magnification IR imaging.
  • Real-time measurement overlay: On-screen crosshair, scale bar, and distance/area annotation via bundled software—calibrated per magnification step using NIST-traceable stage standards.
  • Low-heat LED design: All illumination sources operate below 45°C surface temperature after 60 min continuous use—critical for thermally sensitive samples (e.g., adhesives, biological tissues).

Sample Compatibility & Compliance

The 3R-MSA600SC accommodates flat, curved, or irregularly shaped specimens up to 150 mm in height and unlimited lateral dimension when used with optional XYZ translation stages. It supports direct imaging of PCBs, metallographic mounts, textile weaves, coinage, archival documents, and semiconductor wafers without vacuum or conductive coating. The device meets CE marking requirements under Directive 2014/30/EU (EMC) and 2014/35/EU (LVD); its infrared illumination complies with IEC 62471 Photobiological Safety classification (Risk Group 1 – exempt). For regulated environments, image metadata (timestamp, magnification, illumination mode, calibration ID) is embedded in EXIF headers and supports audit-ready export formats (TIFF with XMP sidecar, CSV log files)—facilitating alignment with ISO/IEC 17025 documentation practices and internal GLP procedures.

Software & Data Management

Bundled Anyty Capture Suite v4.x provides live histogram monitoring, auto-exposure lock, white balance presets (including IR-specific WB), and batch capture scheduling. All captured images and videos are stored with embedded calibration metadata, enabling retrospective magnification validation. Export options include lossless TIFF, compressed MP4 (H.264), and measurement-annotated PDF reports. The software supports DICOM SR (Structured Reporting) export for integration into laboratory information management systems (LIMS) and complies with FDA 21 CFR Part 11 requirements for electronic records through optional password-protected user roles, audit trail logging, and digital signature support.

Applications

  • Electronics manufacturing: Solder joint inspection (IPC-A-610 Class 2/3), wire bond integrity verification, conformal coating thickness estimation.
  • Materials science: Grain boundary mapping on polished metallographic sections, fiber orientation analysis in composites, wear scar quantification on tribological test coupons.
  • Forensic science: Toolmark comparison, ink differentiation on questioned documents, gunshot residue particle morphology.
  • Quality control labs: Surface defect grading per ASTM E2017, coating uniformity assessment, particulate contamination counting (ISO 14644-1 Class 5–8 cleanroom protocols).
  • Educational use: Real-time classroom demonstration of microstructures, student-led comparative morphology studies, remote lab access via network streaming.

FAQ

Is the 200× magnification purely optical or digitally enhanced?
The 200× specification represents maximum usable magnification combining fixed optical zoom (up to 60×) and intelligent digital interpolation—validated against NIST-traceable graticules to ensure measurement linearity within ±3% across the full range.
Can infrared illumination be used simultaneously with white light?
No—illumination modes are mutually exclusive to prevent spectral crosstalk and ensure accurate colorimetric or IR-contrast interpretation; however, rapid sequential toggling (<200 ms switching time) enables comparative multimodal imaging.
Does the microscope support third-party measurement plugins?
Yes—the UVC interface outputs standard YUV422 video streams, allowing integration with OpenCV-based measurement tools, MATLAB Image Processing Toolbox, or custom metrology algorithms deployed on edge devices.
What is the minimum resolvable feature size at 200×?
Based on Rayleigh criterion and sensor Nyquist limit, the practical resolution is approximately 2.8 µm under optimal white-light conditions; IR mode reduces effective resolution to ~4.1 µm due to longer wavelength diffraction limits.
Is calibration certification included with purchase?
A factory-issued calibration report (traceable to CNAS-accredited standards) is provided, documenting magnification accuracy, illumination uniformity, and focus repeatability—valid for 12 months under normal operating conditions.