Empowering Scientific Discovery

inTEST Temptronic ThermoStream ATS-535 High-Speed Thermal Shock System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand inTEST-Temptronic
Origin USA
Model ATS-535
Temperature Range -60°C to +225°C
Temperature Stability ±0.1°C
Temperature Uniformity ±0.1°C
Temperature Accuracy ±1.0°C (NIST-traceable calibration)
Ramp Rate -40°C to +125°C in <12 s
Ramp Rate +125°C to -40°C in <40 s
Airflow Output 5 SCFM (2.4 L/s), constant flow
Control Interface IEEE-488, RS-232, LabVIEW™ drivers
DUT Sensor Support Type T & K thermocouples
Power Requirements Refrigeration Unit: 220 VAC ±10%, 50/60 Hz, 16 A
Compressor Unit 220 VAC ±10%, 50/60 Hz, 30 A
Dimensions 194.7 cm × 61.7 cm × 108.6 cm
Weight 249.5 kg
Noise Level <70 dBA
Refrigerant CFC-free, non-toxic, non-flammable

Overview

The inTEST Temptronic ThermoStream ATS-535 is a high-speed, closed-loop thermal shock system engineered for precision temperature cycling of electronic devices under test (DUTs) in laboratory and production environments. Unlike conventional environmental chambers or cryogenic-based thermal shock systems, the ATS-535 employs an integrated, oil-free air compressor and proprietary forced-air convection architecture to deliver rapid, repeatable, and localized thermal transitions — without reliance on liquid nitrogen (LN₂), dry ice, or external compressed air infrastructure. Its core measurement principle centers on real-time DUT surface temperature feedback control via embedded thermocouple inputs (Type T or K), enabling direct closed-loop regulation of device temperature rather than ambient chamber setpoint tracking. This architecture ensures minimal thermal lag, high reproducibility across thermal cycles, and compliance with industry-critical reliability standards including JEDEC JESD22-A104 (Temperature Cycling), JESD22-A106 (Thermal Shock), and MIL-STD-883 Method 1010.8. Designed for R&D labs, wafer-level test facilities, and qualification engineering teams, the ATS-535 meets stringent requirements for low-noise operation (<70 dBA), footprint efficiency, and regulatory safety — particularly where facility constraints preclude installation of standalone air compressors.

Key Features

  • Integrated oil-free air compressor — eliminates dependency on external compressed air supply, reducing infrastructure complexity and total cost of ownership.
  • Ultra-fast thermal transition: achieves -40°C → +125°C in under 12 seconds and +125°C → -40°C in under 40 seconds, enabling high-throughput thermal stress screening.
  • DUT-centric temperature control algorithm — uses real-time thermocouple feedback from the device surface to dynamically modulate heating/cooling output, minimizing overshoot and improving thermal fidelity.
  • Two operational modes: Air Mode (for ambient airflow characterization) and DUT Mode (for direct device temperature regulation).
  • Over-temperature protection with user-configurable limits — factory default set at +225°C, adjustable per test protocol requirements.
  • Energy-efficient design: refrigeration unit enters standby mode during heating-only phases, reducing power consumption without compromising cycle integrity.
  • CE-compliant and environmentally responsible — utilizes CFC-free, non-toxic, non-flammable refrigerant aligned with ISO 14001 and EPA SNAP program guidelines.
  • Front-panel rotary interface for intuitive manual operation, complemented by programmable digital interfaces (IEEE-488, RS-232) and native LabVIEW™ drivers for automated test integration.

Sample Compatibility & Compliance

The ATS-535 accommodates a broad range of semiconductor packages — including QFN, BGA, SOIC, DFN, and bare die — through customizable thermal chucks, fixture adapters, and interchangeable thermal shrouds. Its localized airflow delivery (5 SCFM, constant-flow) prevents condensation on DUT surfaces by maintaining controlled dew point margins across the full operating range (-60°C to +225°C). The system supports NIST-traceable calibration and is compatible with GLP/GMP documentation workflows, including audit-ready data logging with timestamped temperature profiles and sensor validation records. It satisfies electromagnetic compatibility (EMC) per EN 61326-1 and safety requirements per IEC 61010-1. While not a certified Class I Div 2 instrument, its refrigerant selection and sealed mechanical architecture ensure safe deployment in office-integrated lab spaces, cleanrooms (ISO Class 7–8), and mixed-use R&D campuses.

Software & Data Management

The ATS-535 provides native support for third-party automation frameworks via standard SCPI command sets over IEEE-488 and RS-232. In-house LabVIEW™ drivers enable seamless integration into existing ATE platforms, allowing synchronized triggering between thermal conditioning and electrical parametric testing (e.g., IDDQ, functional timing, leakage current). All temperature data — including setpoints, actual DUT readings, airflow status, and alarm events — are logged internally with millisecond-resolution timestamps and exportable in CSV format. Optional software modules support 21 CFR Part 11-compliant user access control, electronic signatures, and audit trail generation for regulated industries (e.g., aerospace, medical electronics). Calibration certificates include uncertainty budgets traceable to NIST standards, with recommended recalibration intervals aligned with ISO/IEC 17025 practices.

Applications

  • Qualification testing of power management ICs (PMICs), RF transceivers, and automotive-grade microcontrollers under JEDEC and AEC-Q200 thermal shock conditions.
  • Wafer-level burn-in and failure analysis (FA) requiring sub-second thermal ramp fidelity and minimal thermal mass interference.
  • Thermal validation of MEMS sensors, optical transceivers, and satellite communication components operating in extreme orbital thermal environments.
  • Process development for advanced packaging technologies (e.g., fan-out wafer-level packaging, 2.5D/3D IC stacking) where interfacial delamination and CTE mismatch must be assessed under accelerated thermal cycling.
  • Reliability engineering for defense electronics subject to MIL-STD-810G thermal shock profiles and NATO STANAG 4370 environmental compliance.

FAQ

Does the ATS-535 require external compressed air?
No — it features a fully integrated, maintenance-free air compressor, eliminating the need for external air lines, dryers, or pressure regulators.
What thermocouple types are supported for DUT temperature monitoring?
Type T and Type K thermocouples are natively supported via dedicated analog input channels with cold-junction compensation.
Can the system operate continuously across its full temperature range?
Yes — rated for continuous duty within -60°C to +225°C, with thermal uniformity maintained at ±0.1°C across the DUT interface plane.
Is the ATS-535 suitable for use in office environments?
Yes — its <70 dBA acoustic signature and absence of external utility dependencies make it deployable in shared R&D floors, innovation hubs, and ISO-certified lab suites.
How is temperature accuracy verified and maintained?
Each unit ships with a NIST-traceable calibration certificate; field recalibration is performed using dual-point verification against reference thermistors or PRTs per ASTM E74 and ISO/IEC 17025 protocols.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0