Added to wishlistRemoved from wishlist 0
Add to compare
BrandinTEST-Temptronic
OriginUSA
ModelATS-535
High Temperature Range+225°C
Low Temperature Range−60°C
Thermal Shock Range−60°C to +225°C
Temperature Stability±0.01°C
Heating Rate−40°C to +125°C in <12 s
Cooling Rate+125°C to −40°C in <40 s
Airflow Output5 SCFM (2.4 L/s)
Temperature Resolution±0.1°C
Temperature Accuracy±1.0°C (NIST-traceable calibration)
DUT Temperature ControlClosed-loop algorithm with T- or K-type thermocouple input
Power SupplyRefrigeration unit: 220 VAC ±10%, 50/60 Hz, 16 A
Compressor220 VAC ±10%, 50/60 Hz, 30 A
Dimensions194.7 × 61.7 × 108.6 cm
Weight249.5 kg
Noise Level<70 dBA
ComplianceCE, CFC-free refrigerant (non-toxic, non-flammable), RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
ModelASM340W
Detection Limit< 5 × 10⁻¹³ Pa·m³/s
Leak Detection MethodVacuum Mode (Bypass Connection)
ComplianceCE, RoHS, ISO 9001-certified Manufacturing
InterfaceRS232, Ethernet, Analog Output (0–10 V)
Power Supply100–240 V AC, 50/60 Hz
Operating Temperature10–40 °C
Weight28 kg
Dimensions (W × H × D)482 × 132 × 500 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelHiScroll 12
Pump TypeOil-Free Dry Scroll
Pumping Speed12.1 m³/h
Ultimate Pressure6 × 10⁻³ hPa
Noise Level47 dB(A)
Weight24 kg
Inlet FlangeDN 25 ISO-KF
Operating Voltage100–127 / 200–240 V AC (±10%), 50/60 Hz
Protection ClassIP20
Explosion-Proof OptionEx II 3G Ex h IIC T4 Gc X (Ta: +5 °C to +40 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandinTEST- Temptronic
OriginUSA
ModelECO-710
Temperature Range (°C)-80 to +225
Temperature Stability (°C)±0.01
Transition Time (°C)+125 to −55°C in ~10 s
Airflow Output4–18 scfm (1.8–8.5 L/s)
Temperature Accuracy±1°C
Temperature Resolution0.1°C
Noise Level≤56 dBA
Input Power20 A
RefrigerantNon-ozone-depleting, non-flammable HFC blend
ComplianceRoHS, CE, UL 61010-1, IEC 61000-6-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelQMG 250
Detection PrincipleQuadrupole Mass Spectrometry
ConfigurationOnline, Integrated Vacuum System
Mass Rangeup to 300 amu
Repeatability≤ ±0.5% RSD (for masses < 300)
Response Time< 1 s (typical for partial pressure monitoring)
System IncludesQMG 250 quadrupole mass spectrometer, HiCube 80 turbomolecular pump set, PKR 251 cold cathode vacuum gauge, and custom four-way stainless-steel chamber assembly
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelHiQuad™
Measurement PrincipleQuadrupole mass spectrometry with electron ionization (EI), optimized for real-time, high-speed quantitative gas analysis in industrial process environments
Mass Range1–128 u, 1–300 u, or 1–512 u (configurable per QMA analyzer variant)
Minimum Detectable Partial Pressure5×10⁻¹⁶ mbar (QMA 410), 2×10⁻¹⁵ mbar (QMA 430), 1×10⁻¹⁵ mbar (Ar, QMA 400)
Sensitivity (Faraday, 1 mA emission)1×10⁻³ A/mbar (QMA 410), 2×10⁻⁴ A/mbar (QMA 430), 5×10⁻⁴ A/mbar (QMA 400)
Max. Operating Pressure (Faraday)1×10⁻⁴ mbar
Max. Operating Pressure (SEM)1×10⁻⁵ mbar
Isotopic Ratio Precision (e.g., ⁴⁰Ar/⁴¹Ar)< 0.3 ppb SEM resolution
Analyzer Temperature150 °C (operational), 400 °C (bake-out)
Scan Speedup to 125 µs per atomic mass unit
Long-Term Stability< 0.1 % drift over 8 hours
Ion SourceOff-axis biased electron impact source with magnetic field enhancement for low background and high signal-to-noise ratio
Detector OptionsFaraday cup and secondary electron multiplier (SEM)
InterfaceIntegrated OPC UA server and embedded web browser
SoftwareQuadera® platform for real-time data acquisition, matrix-based concentration calculation, and multi-channel calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
Pump TypeOil-Free Turbo Molecular Pump
ModelHiPace 80
Nominal Pumping Speed (N₂)71 L/s
Compression Ratio (N₂)>1×10¹¹
Ultimate Pressure (N₂)<1×10⁻⁷ hPa
Maximum Starting Pressure (N₂)2.2 mbar
Pumping Speed (He)58 L/s
Pumping Speed (H₂)48 L/s
Inlet FlangeDN 63 ISO-K / DN 63 CF-F / DN 40 ISO-KF
CoolingNatural Air Cooling
Enclosure RatingIP54
CertificationsUL/CSA, Semiconductor S2
MountingOmnidirectional
Weight1.75 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
ModelASI 35
Detection Limit (Vacuum Mode, High Sensitivity)5×10⁻¹² mbar·L/s
Detection Limit (Sniffer Mode)1.5×10⁻⁸ mbar·L/s
Helium Pumping Speed (High Sensitivity Mode)6 L/s
Minimum Starting Pressure (High Sensitivity Mode)0.2 mbar
Analyzer InterfaceDN 25 ISO-KF & DN 16 ISO-KF
Communication InterfacesRS-232, Ethernet, PROFIBUS, USB
I/O Configuration6 digital inputs, 3 analog outputs, 5 relay outputs, 4 transistor/open-collector outputs
Dimensions (Vacuum Module)279 × 264 × 197 mm
Weight (Vacuum Module)15 kg
Operating Temperature10–45 °C
Power Supply90–240 V AC, 50/60 Hz
Max. Power Consumption300 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAmbrell EKOHEAT® Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelPCR 280
Measurement PrincipleCapacitance manometry with integrated Pirani sensor
Range5 × 10⁻⁵ to 1500 hPa
Vacuum Port OptionsDN 16 ISO-KF, DN 16 CF-F, or custom flange
Operating Voltage15–30 V DC
Output Signal1.2–8.68 V analog
Bakeout Temperature80 °C
Accuracy±50% (5 × 10⁻⁴–1 × 10⁻³ hPa), ±15% (1 × 10⁻³–100 hPa), ±5% (100–950 hPa), ±2.5% (950–1100 hPa)
Ultimate Pressure5000 hPa (overpressure limit)
Weight120 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNS
OriginJapan
ModelNS-5
Ion Source TypeKaufman-type
Beam Diameter10 cm
Sample Stage CoolingDirect-contact cryogenic cooling
Stage MotionCombined rotation and revolution
Beam Tilt AdjustmentFully variable (0–90°)
Application ScopeR&D and low-volume production
Substrate CompatibilityUp to 6-inch diameter wafers
Power Supply CompatibilityInterchangeable with domestic 220 V / 50 Hz AC input
ComplianceDesigned for ISO Class 5 cleanroom integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKaufman
OriginUSA
ModelRFICP 220
Anode Power2 kW @ 2 MHz
Max Beam Current>1000 mA
Ion Energy Range100–1200 eV
Beam Diameter22 cm
Gas CompatibilityAr, O₂, N₂, others
Gas Flow5–50 sccm
Operating Pressure<0.5 mTorr
Grid MaterialMolybdenum
Ion OpticsOptiBeam™ self-aligning electrostatic lens system
NeutralizerLFN 2000 or MHC 1000
Flange10" CF
Dimensions (H × D)30 cm × 41 cm
ComplianceDesigned for UHV integration and compatible with ISO-KF/CF vacuum standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
Pump TypeOil-Free Turbo Molecular Pump
Bearing SystemHybrid (Ceramic Ball + Active Magnetic)
Nominal Pumping Speed Range300–790 L/s (N₂)
Ultimate Pressure< 1 × 10⁻⁷ hPa
Compression Ratio (N₂)> 1 × 10¹¹
Max. Starting Pressure10 hPa
Integrated ControllerYes
CoolingIntegrated Water Cooling
Mounting FlexibilityAny Orientation
Ingress ProtectionIP54
CertificationsSEMI S2, UL 61010-1
Interface OptionsProfibus, DeviceNet, E74
Added to wishlistRemoved from wishlist 0
Add to compare
BrandinTEST–Temptronic
OriginUSA
ModelATS-710E
High-Temperature Range0 to 225 °C
Low-Temperature Range−80 to 0 °C
Thermal Shock Range−80 to +225 °C
Temperature Stability±1 °C
Heating Rate~10 s from −55 °C to +125 °C
Cooling Rate~10 s from +125 °C to −55 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandinTEST–Temptronic
OriginUSA
Manufacturer TypeAuthorized Distributor (Imported)
ModelATS-750
Price RangeUSD 28,000 – 70,000 (FOB)
Temperature Range−85 °C to +300 °C (50 Hz) / −90 °C to +300 °C (60 Hz)
Airflow Output4–18 SCFM (1.8–8.5 L/s)
Transition Rate−55 °C → +125 °C in ~10 s
Temperature Stability±0.01 °C
Temperature Accuracy±1 °C (NIST-traceable calibration)
Temperature Resolution0.1 °C
Sensor TypeT-type or K-type thermocouple
Control InterfacesIEEE-488 (GPIB), RS-232, Ethernet
Operating ModesAir Mode & DUT Mode
ComplianceCE, RoHS, FDA 21 CFR Part 11 (via optional audit trail software), GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEuroplasma
OriginBelgium
ModelCD 1000
Coating Thickness50–500 nm (single-layer), 1–3 µm (multi-layer)
Waterproof RatingIPX2–IPX8
Cycle Time10–30 min (standard), 3–4 h (multi-layer)
Substrate CompatibilityNonwovens, polymer films, meshes, nanofiber webs, PCBs, electronic assemblies, 3D components
ComplianceISO 10993-5 (cytotoxicity), ISO 10993-10 (irritation/sensitization), halogen-free formulation
Operating EnvironmentLow-pressure plasma chamber, vacuum-based surface polymerization & atomic layer deposition (ALD)-compatible process
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
ModelASM182 TD+
Detection PrincipleHelium-Specific Mass Spectrometry (m/z = 4)
Minimum Detectable Leak Rate≤5×10⁻⁸ mbar·L/s
Pumping Speed (Foreline)≥18 m³/h (with recommended backing pump)
Mass Analyzer TypeMagnetic Sector or Quadrupole (TD+ variant optimized for trace helium sensitivity)
ComplianceCE, RoHS, ISO 9001 certified manufacturing
InterfaceRS-232, Ethernet, Analog I/O (0–10 V / 4–20 mA)
Operating Environment15–35 °C, <80% RH non-condensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
Pump TypeOil-Free Dry Scroll
Ultimate Vacuum1 × 10⁻² mbar
Pumping Speed15–40 m³/h (ACP 15: 14 m³/h, ACP 28: 27 m³/h, ACP 40: 37 m³/h)
Maximum Inlet Pressure1000 mbar (abs)
Base Weight23–32 kg
Motor SupplySingle- or Three-Phase
CertificationsCE, UL/CSA, SEMI S2
Gas Ballast OptionStandard (SD), Corrosion-Resistant (G), Water-Vapor-Tolerant (CV)
Maintenance Interval20,000–22,000 hours (full overhaul)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
ModelASM 390, ASM 392
Detection Gas4He, 3He, H₂
Minimum Detectable Leak Rate (Vacuum Mode)1×10⁻¹² mbar·L/s
Minimum Detectable Leak Rate (Sniffer Mode)1×10⁻⁸ mbar·L/s
Helium Pumping Speed10 L/s (ASM 390), 25 L/s (ASM 392)
Forepump Speed35 m³/h
Max Inlet Pressure20 mbar
Warm-up Time (Un-calibrated, 20°C)2 min
Inlet PortDN 40 ISO-KF
Response Time< 1 s
Interface OptionsRS-232, Digital I/O, Ethernet
Noise Level≤ 55 dB(A)
Weight125 kg (ASM 390), 130 kg (ASM 392)
Dimensions (L×W×H)1072 × 455 × 1025 mm
CertificationsCE, ETL, UL 61010, SEMI S2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginFrance
ModelASM 182 T / ASM 182 TD+
Forevacuum Pump Speed20–25 m³/h (oil-sealed or dry scroll)
Helium Throughput4.4 L/s
Minimum Detectable Leak Rate (He)5×10⁻¹³ Pa·m³/s (vacuum mode), 1×10⁻⁸ Pa·m³/s (sniffer mode)
Inlet FlangeDN 40 ISO-KF
Max Inlet Pressure6 hPa
Power Supply200–240 V, 50/60 Hz (also available 110–130 V variants)
Warm-up Time≤4 min
Weight76–88 kg
Dimensions (L×W×H)594×434×444 mm (T) / 601×487×456 mm (TD+)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEuroplasma
OriginBelgium
ModelNanofics®
RF Power5 kW
Chamber Dimensions700 × 700 × 1200 mm
Chamber Volume490 L
Chamber MaterialAluminum
Process GasesO₂, Ar, and other reactive/inert gases
Control SystemFully Automated
Equipment TypeImported Plasma Surface Treatment System
ApplicationIndustrial-scale PECVD nanocoating for electronics waterproofing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEuroplasma
OriginBelgium
ModelCD 2400
Power5 kW
Dimensions2400 mm × Ø1000 mm
Chamber Volume2000 L
Chamber MaterialAluminum
Process GasesO₂, Ar
Control ModeFully Automatic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEuroplasma
OriginBelgium
ModelCD 600 PLC
RF Frequency50 Hz
Power Supply380 V AC, 3-phase, 40 A
Chamber Dimensions600 × 600 × 600 mm
Chamber Volume216 L
Chamber MaterialAnodized Aluminum
Control SystemPLC-based with 17″ Touchscreen HMI
Vacuum SystemDry Scroll Pump, 480 m³/h Pumping Speed
Vacuum MeasurementDual Pirani Gauges
Gas Inlet1/4″ (6.45 mm) port with Mass Flow Controller (MFC), 1 bar max inlet pressure
Exhaust Port28 mm diameter
Safety FeaturesEmergency Stop, Vacuum Interlock, Overtemperature Protection, CE Certified
ComplianceFully CE-marked for industrial laboratory use under EU Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPfeiffer Vacuum
OriginGermany
ModelASI35
Detection ModeVacuum (Sniffer/Probe or Vacuum Chamber Compatible)
Minimum Detectable Leak Rate5 × 10⁻¹² mbar·L/s (typical, helium)
Integrated InterfaceRS232/RS485, Ethernet, Digital I/O for PLC Integration
ComplianceCE, RoHS, ISO 9001 Manufacturing
Application-Specific ConfigurationOEM-ready module for automated fuel tank leak testing systems