- All
- Favorite
- Popular
- Most rated
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-535 |
| High Temperature Range | +225°C |
| Low Temperature Range | −60°C |
| Thermal Shock Range | −60°C to +225°C |
| Temperature Stability | ±0.01°C |
| Heating Rate | −40°C to +125°C in <12 s |
| Cooling Rate | +125°C to −40°C in <40 s |
| Airflow Output | 5 SCFM (2.4 L/s) |
| Temperature Resolution | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| DUT Temperature Control | Closed-loop algorithm with T- or K-type thermocouple input |
| Power Supply | Refrigeration unit: 220 VAC ±10%, 50/60 Hz, 16 A |
| Compressor | 220 VAC ±10%, 50/60 Hz, 30 A |
| Dimensions | 194.7 × 61.7 × 108.6 cm |
| Weight | 249.5 kg |
| Noise Level | <70 dBA |
| Compliance | CE, CFC-free refrigerant (non-toxic, non-flammable), RoHS |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM340W |
| Detection Limit | < 5 × 10⁻¹³ Pa·m³/s |
| Leak Detection Method | Vacuum Mode (Bypass Connection) |
| Compliance | CE, RoHS, ISO 9001-certified Manufacturing |
| Interface | RS232, Ethernet, Analog Output (0–10 V) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 10–40 °C |
| Weight | 28 kg |
| Dimensions (W × H × D) | 482 × 132 × 500 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiScroll 12 |
| Pump Type | Oil-Free Dry Scroll |
| Pumping Speed | 12.1 m³/h |
| Ultimate Pressure | 6 × 10⁻³ hPa |
| Noise Level | 47 dB(A) |
| Weight | 24 kg |
| Inlet Flange | DN 25 ISO-KF |
| Operating Voltage | 100–127 / 200–240 V AC (±10%), 50/60 Hz |
| Protection Class | IP20 |
| Explosion-Proof Option | Ex II 3G Ex h IIC T4 Gc X (Ta: +5 °C to +40 °C) |
| Brand | inTEST- Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710 |
| Temperature Range (°C) | -80 to +225 |
| Temperature Stability (°C) | ±0.01 |
| Transition Time (°C) | +125 to −55°C in ~10 s |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Accuracy | ±1°C |
| Temperature Resolution | 0.1°C |
| Noise Level | ≤56 dBA |
| Input Power | 20 A |
| Refrigerant | Non-ozone-depleting, non-flammable HFC blend |
| Compliance | RoHS, CE, UL 61010-1, IEC 61000-6-3 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | QMG 250 |
| Detection Principle | Quadrupole Mass Spectrometry |
| Configuration | Online, Integrated Vacuum System |
| Mass Range | up to 300 amu |
| Repeatability | ≤ ±0.5% RSD (for masses < 300) |
| Response Time | < 1 s (typical for partial pressure monitoring) |
| System Includes | QMG 250 quadrupole mass spectrometer, HiCube 80 turbomolecular pump set, PKR 251 cold cathode vacuum gauge, and custom four-way stainless-steel chamber assembly |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiQuad™ |
| Measurement Principle | Quadrupole mass spectrometry with electron ionization (EI), optimized for real-time, high-speed quantitative gas analysis in industrial process environments |
| Mass Range | 1–128 u, 1–300 u, or 1–512 u (configurable per QMA analyzer variant) |
| Minimum Detectable Partial Pressure | 5×10⁻¹⁶ mbar (QMA 410), 2×10⁻¹⁵ mbar (QMA 430), 1×10⁻¹⁵ mbar (Ar, QMA 400) |
| Sensitivity (Faraday, 1 mA emission) | 1×10⁻³ A/mbar (QMA 410), 2×10⁻⁴ A/mbar (QMA 430), 5×10⁻⁴ A/mbar (QMA 400) |
| Max. Operating Pressure (Faraday) | 1×10⁻⁴ mbar |
| Max. Operating Pressure (SEM) | 1×10⁻⁵ mbar |
| Isotopic Ratio Precision (e.g., ⁴⁰Ar/⁴¹Ar) | < 0.3 ppb SEM resolution |
| Analyzer Temperature | 150 °C (operational), 400 °C (bake-out) |
| Scan Speed | up to 125 µs per atomic mass unit |
| Long-Term Stability | < 0.1 % drift over 8 hours |
| Ion Source | Off-axis biased electron impact source with magnetic field enhancement for low background and high signal-to-noise ratio |
| Detector Options | Faraday cup and secondary electron multiplier (SEM) |
| Interface | Integrated OPC UA server and embedded web browser |
| Software | Quadera® platform for real-time data acquisition, matrix-based concentration calculation, and multi-channel calibration |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Model | HiPace 80 |
| Nominal Pumping Speed (N₂) | 71 L/s |
| Compression Ratio (N₂) | >1×10¹¹ |
| Ultimate Pressure (N₂) | <1×10⁻⁷ hPa |
| Maximum Starting Pressure (N₂) | 2.2 mbar |
| Pumping Speed (He) | 58 L/s |
| Pumping Speed (H₂) | 48 L/s |
| Inlet Flange | DN 63 ISO-K / DN 63 CF-F / DN 40 ISO-KF |
| Cooling | Natural Air Cooling |
| Enclosure Rating | IP54 |
| Certifications | UL/CSA, Semiconductor S2 |
| Mounting | Omnidirectional |
| Weight | 1.75 kg |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASI 35 |
| Detection Limit (Vacuum Mode, High Sensitivity) | 5×10⁻¹² mbar·L/s |
| Detection Limit (Sniffer Mode) | 1.5×10⁻⁸ mbar·L/s |
| Helium Pumping Speed (High Sensitivity Mode) | 6 L/s |
| Minimum Starting Pressure (High Sensitivity Mode) | 0.2 mbar |
| Analyzer Interface | DN 25 ISO-KF & DN 16 ISO-KF |
| Communication Interfaces | RS-232, Ethernet, PROFIBUS, USB |
| I/O Configuration | 6 digital inputs, 3 analog outputs, 5 relay outputs, 4 transistor/open-collector outputs |
| Dimensions (Vacuum Module) | 279 × 264 × 197 mm |
| Weight (Vacuum Module) | 15 kg |
| Operating Temperature | 10–45 °C |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ambrell EKOHEAT® Series |
| Pricing | Available Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PCR 280 |
| Measurement Principle | Capacitance manometry with integrated Pirani sensor |
| Range | 5 × 10⁻⁵ to 1500 hPa |
| Vacuum Port Options | DN 16 ISO-KF, DN 16 CF-F, or custom flange |
| Operating Voltage | 15–30 V DC |
| Output Signal | 1.2–8.68 V analog |
| Bakeout Temperature | 80 °C |
| Accuracy | ±50% (5 × 10⁻⁴–1 × 10⁻³ hPa), ±15% (1 × 10⁻³–100 hPa), ±5% (100–950 hPa), ±2.5% (950–1100 hPa) |
| Ultimate Pressure | 5000 hPa (overpressure limit) |
| Weight | 120 g |
| Brand | NS |
|---|---|
| Origin | Japan |
| Model | NS-5 |
| Ion Source Type | Kaufman-type |
| Beam Diameter | 10 cm |
| Sample Stage Cooling | Direct-contact cryogenic cooling |
| Stage Motion | Combined rotation and revolution |
| Beam Tilt Adjustment | Fully variable (0–90°) |
| Application Scope | R&D and low-volume production |
| Substrate Compatibility | Up to 6-inch diameter wafers |
| Power Supply Compatibility | Interchangeable with domestic 220 V / 50 Hz AC input |
| Compliance | Designed for ISO Class 5 cleanroom integration |
| Brand | Kaufman |
|---|---|
| Origin | USA |
| Model | RFICP 220 |
| Anode Power | 2 kW @ 2 MHz |
| Max Beam Current | >1000 mA |
| Ion Energy Range | 100–1200 eV |
| Beam Diameter | 22 cm |
| Gas Compatibility | Ar, O₂, N₂, others |
| Gas Flow | 5–50 sccm |
| Operating Pressure | <0.5 mTorr |
| Grid Material | Molybdenum |
| Ion Optics | OptiBeam™ self-aligning electrostatic lens system |
| Neutralizer | LFN 2000 or MHC 1000 |
| Flange | 10" CF |
| Dimensions (H × D) | 30 cm × 41 cm |
| Compliance | Designed for UHV integration and compatible with ISO-KF/CF vacuum standards |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Bearing System | Hybrid (Ceramic Ball + Active Magnetic) |
| Nominal Pumping Speed Range | 300–790 L/s (N₂) |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Compression Ratio (N₂) | > 1 × 10¹¹ |
| Max. Starting Pressure | 10 hPa |
| Integrated Controller | Yes |
| Cooling | Integrated Water Cooling |
| Mounting Flexibility | Any Orientation |
| Ingress Protection | IP54 |
| Certifications | SEMI S2, UL 61010-1 |
| Interface Options | Profibus, DeviceNet, E74 |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710E |
| High-Temperature Range | 0 to 225 °C |
| Low-Temperature Range | −80 to 0 °C |
| Thermal Shock Range | −80 to +225 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | ~10 s from −55 °C to +125 °C |
| Cooling Rate | ~10 s from +125 °C to −55 °C |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (Imported) |
| Model | ATS-750 |
| Price Range | USD 28,000 – 70,000 (FOB) |
| Temperature Range | −85 °C to +300 °C (50 Hz) / −90 °C to +300 °C (60 Hz) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Transition Rate | −55 °C → +125 °C in ~10 s |
| Temperature Stability | ±0.01 °C |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488 (GPIB), RS-232, Ethernet |
| Operating Modes | Air Mode & DUT Mode |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (via optional audit trail software), GLP/GMP-ready |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | CD 1000 |
| Coating Thickness | 50–500 nm (single-layer), 1–3 µm (multi-layer) |
| Waterproof Rating | IPX2–IPX8 |
| Cycle Time | 10–30 min (standard), 3–4 h (multi-layer) |
| Substrate Compatibility | Nonwovens, polymer films, meshes, nanofiber webs, PCBs, electronic assemblies, 3D components |
| Compliance | ISO 10993-5 (cytotoxicity), ISO 10993-10 (irritation/sensitization), halogen-free formulation |
| Operating Environment | Low-pressure plasma chamber, vacuum-based surface polymerization & atomic layer deposition (ALD)-compatible process |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM182 TD+ |
| Detection Principle | Helium-Specific Mass Spectrometry (m/z = 4) |
| Minimum Detectable Leak Rate | ≤5×10⁻⁸ mbar·L/s |
| Pumping Speed (Foreline) | ≥18 m³/h (with recommended backing pump) |
| Mass Analyzer Type | Magnetic Sector or Quadrupole (TD+ variant optimized for trace helium sensitivity) |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Interface | RS-232, Ethernet, Analog I/O (0–10 V / 4–20 mA) |
| Operating Environment | 15–35 °C, <80% RH non-condensing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Pump Type | Oil-Free Dry Scroll |
| Ultimate Vacuum | 1 × 10⁻² mbar |
| Pumping Speed | 15–40 m³/h (ACP 15: 14 m³/h, ACP 28: 27 m³/h, ACP 40: 37 m³/h) |
| Maximum Inlet Pressure | 1000 mbar (abs) |
| Base Weight | 23–32 kg |
| Motor Supply | Single- or Three-Phase |
| Certifications | CE, UL/CSA, SEMI S2 |
| Gas Ballast Option | Standard (SD), Corrosion-Resistant (G), Water-Vapor-Tolerant (CV) |
| Maintenance Interval | 20,000–22,000 hours (full overhaul) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 390, ASM 392 |
| Detection Gas | 4He, 3He, H₂ |
| Minimum Detectable Leak Rate (Vacuum Mode) | 1×10⁻¹² mbar·L/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ mbar·L/s |
| Helium Pumping Speed | 10 L/s (ASM 390), 25 L/s (ASM 392) |
| Forepump Speed | 35 m³/h |
| Max Inlet Pressure | 20 mbar |
| Warm-up Time (Un-calibrated, 20°C) | 2 min |
| Inlet Port | DN 40 ISO-KF |
| Response Time | < 1 s |
| Interface Options | RS-232, Digital I/O, Ethernet |
| Noise Level | ≤ 55 dB(A) |
| Weight | 125 kg (ASM 390), 130 kg (ASM 392) |
| Dimensions (L×W×H) | 1072 × 455 × 1025 mm |
| Certifications | CE, ETL, UL 61010, SEMI S2 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 182 T / ASM 182 TD+ |
| Forevacuum Pump Speed | 20–25 m³/h (oil-sealed or dry scroll) |
| Helium Throughput | 4.4 L/s |
| Minimum Detectable Leak Rate (He) | 5×10⁻¹³ Pa·m³/s (vacuum mode), 1×10⁻⁸ Pa·m³/s (sniffer mode) |
| Inlet Flange | DN 40 ISO-KF |
| Max Inlet Pressure | 6 hPa |
| Power Supply | 200–240 V, 50/60 Hz (also available 110–130 V variants) |
| Warm-up Time | ≤4 min |
| Weight | 76–88 kg |
| Dimensions (L×W×H) | 594×434×444 mm (T) / 601×487×456 mm (TD+) |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | Nanofics® |
| RF Power | 5 kW |
| Chamber Dimensions | 700 × 700 × 1200 mm |
| Chamber Volume | 490 L |
| Chamber Material | Aluminum |
| Process Gases | O₂, Ar, and other reactive/inert gases |
| Control System | Fully Automated |
| Equipment Type | Imported Plasma Surface Treatment System |
| Application | Industrial-scale PECVD nanocoating for electronics waterproofing |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | CD 2400 |
| Power | 5 kW |
| Dimensions | 2400 mm × Ø1000 mm |
| Chamber Volume | 2000 L |
| Chamber Material | Aluminum |
| Process Gases | O₂, Ar |
| Control Mode | Fully Automatic |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | CD 600 PLC |
| RF Frequency | 50 Hz |
| Power Supply | 380 V AC, 3-phase, 40 A |
| Chamber Dimensions | 600 × 600 × 600 mm |
| Chamber Volume | 216 L |
| Chamber Material | Anodized Aluminum |
| Control System | PLC-based with 17″ Touchscreen HMI |
| Vacuum System | Dry Scroll Pump, 480 m³/h Pumping Speed |
| Vacuum Measurement | Dual Pirani Gauges |
| Gas Inlet | 1/4″ (6.45 mm) port with Mass Flow Controller (MFC), 1 bar max inlet pressure |
| Exhaust Port | 28 mm diameter |
| Safety Features | Emergency Stop, Vacuum Interlock, Overtemperature Protection, CE Certified |
| Compliance | Fully CE-marked for industrial laboratory use under EU Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASI35 |
| Detection Mode | Vacuum (Sniffer/Probe or Vacuum Chamber Compatible) |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s (typical, helium) |
| Integrated Interface | RS232/RS485, Ethernet, Digital I/O for PLC Integration |
| Compliance | CE, RoHS, ISO 9001 Manufacturing |
| Application-Specific Configuration | OEM-ready module for automated fuel tank leak testing systems |