Varian Archon Purge and Trap Autosampler for Aqueous Samples

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Varian
Origin USA
Instrument Type Purge and Trap Autosampler
Application Aqueous Sample Introduction for GC Analysis
Model Designation Archon (Aqueous-Only Configuration)
Operational Age 3–4 Years
Warranty 6 Months Limited Hardware Warranty
Compliance Context Designed to meet ASTM D5024, EPA Method 502.2, EPA Method 624, and ISO 15681-1 requirements for volatile organic compound (VOC) analysis in water

Overview

The Varian Archon Purge and Trap Autosampler for Aqueous Samples is a dedicated, high-reliability sample introduction system engineered for the quantitative analysis of volatile organic compounds (VOCs) in water matrices by gas chromatography (GC) or GC–mass spectrometry (GC–MS). Based on the well-established purge-and-trap principle—where inert gas purges VOCs from an aqueous sample into a sorbent trap, followed by thermal desorption into the GC column—the Archon delivers consistent, low-level detection performance with minimal carryover and robust inter-run reproducibility. Designed exclusively for aqueous applications (not compatible with soil, sediment, or solid-phase extraction), this unit integrates seamlessly with Varian/Agilent GC systems and supports automated batch processing of up to 40 vials per sequence. Its architecture emphasizes mechanical stability, precise temperature control of the purge chamber (±0.5 °C), and calibrated flow regulation across the purge, dry, and desorb stages—critical parameters for method compliance under regulatory frameworks including U.S. EPA Methods 502.2 and 624.

Key Features

  • Dedicated aqueous-only configuration ensures optimized purge efficiency and reduced matrix interference for drinking water, wastewater, and groundwater samples
  • Integrated thermal desorption module with programmable trap heating (up to 350 °C) and backflush capability for extended sorbent life and low blank performance
  • Automated reagent delivery for internal standard spiking (e.g., fluorobenzene, bromofluorobenzene) prior to purge, supporting EPA-mandated surrogate recovery tracking
  • Robust Peltier-cooled condenser stage maintains trap integrity during desorption, minimizing analyte loss and improving sensitivity for C2–C12 VOCs
  • Self-diagnostics and real-time status monitoring via front-panel LED indicators and RS-232 interface for integration into LIMS or instrument control software
  • Factory-aligned gas flow calibration verified with certified mass flow meters; purge flow accuracy ±2% of setpoint (typically 40 mL/min)

Sample Compatibility & Compliance

The Archon aqueous autosampler accepts standard 40-mL VOA vials with crimp-top seals and accommodates both unspiked and pre-spiked sample formats. It is validated for use with common sorbent traps—including Tenax TA, Carbopack B, and Carbopack C combinations—as specified in EPA Method 502.2. The system supports full compliance with U.S. Environmental Protection Agency (EPA) protocols for VOC analysis in environmental water samples, including required initial calibration verification (ICV), laboratory control sample (LCS), and continuing calibration verification (CCV) routines. Its operational design aligns with ISO 15681-1:2003 for determination of VOCs in water by purge-and-trap GC, and meets hardware prerequisites for GLP-compliant laboratories performing contract environmental testing. Note: Full regulatory compliance requires user validation per 40 CFR Part 136 and adherence to site-specific SOPs.

Software & Data Management

While the Archon operates as a standalone hardware module, it interfaces directly with Varian Star Chromatography Workstation (v6.x and later) and Agilent ChemStation (via emulation mode) for synchronized method execution and event logging. All purge-and-trap timing parameters—including purge time (5–30 min), bake time (5–15 min), and desorption time (2–5 min)—are fully programmable and stored in instrument memory. Audit trails for method changes, run logs, and error codes are retained locally and exportable via serial output. For laboratories operating under FDA 21 CFR Part 11 requirements, integration with validated LIMS platforms enables electronic signature capture, user access controls, and immutable data archiving when paired with compliant GC data systems.

Applications

  • Regulatory monitoring of VOCs in municipal drinking water supplies per EPA Safe Drinking Water Act (SDWA) standards
  • Wastewater effluent characterization for industrial discharge permitting (NPDES)
  • Groundwater assessment at Superfund sites and brownfield remediation projects
  • Method development and validation studies for emerging contaminants (e.g., chlorinated solvents, BTEX, vinyl chloride)
  • Quality assurance/quality control (QA/QC) in environmental testing laboratories accredited to ISO/IEC 17025

FAQ

Is this unit compatible with non-aqueous matrices such as soil extracts or solid samples?
No—the Archon aqueous-only configuration lacks the hardware modules (e.g., sample heater, sparge probe adapter) required for solid-phase purge-and-trap. It is strictly intended for liquid water samples.
Does the 6-month warranty cover consumables such as traps, frits, or septa?
No—warranty covers defects in materials and workmanship of core electromechanical components only. Consumables are excluded per standard industry practice.
Can the Archon be upgraded to support EPA Method 524.4 (purge-and-trap GC/MS for drinking water)?
Yes—provided the host GC–MS system meets Method 524.4 requirements (e.g., SIM acquisition, retention time locking), the Archon’s hardware is fully compatible; method-specific tuning and calibration remain the user’s responsibility.
Are original Varian service manuals and spare parts documentation included?
Yes—each unit ships with scanned PDF copies of the Archon Operator’s Manual, Maintenance Guide, and electrical schematics, plus a list of currently available OEM-compatible replacement parts.